Specification Sheet
09/20 1200 Series Config 1000 Bubbler Deactivation Page 2 of 2
A. DEACTIVATION OF THE BUBBLER(S)
1. Remove the clear plastic cover underneath the bowl on the right side or single unit
by using a T20 torx bit.
2. Locate the component on the circuit board that has eight numbered switches. It is
adjacent to the blue button. Using a nonmetallic pointed object such as a
mechanical pencil tip, change the position of switch 1 to the “ON” position by
sliding it up. Switch 1 is on the left, closest to the blue button.
3. Verify that the bubbler(s) have been deactivated by pressing the pushbar or
putting a hand in front of the sensor (if applicable). The bottle filler display should
be displaying a “fountain off” message every ten seconds.
4. Reinstall the clear plastic cover.
B. INSTALLATION OF THE COVER PLATE(S)
(OPTIONAL BUT HIGHLY RECOMMENDED)
5. Disconnect power to the unit via the breaker or by removing the skirt and
unplugging the main power cord.
6. Remove the black plastic cover underneath the bowl by removing the (4) screws using either a phillips bit or 5/16” nut
driver.
7. Remove the (3) T20 head screws attaching the bubbler to the bowl, then pull up on the bubbler to release the push-to-
connect fitting from it.
8. Store the bubbler and T20 head screws in a safe location so that they can be reinstalled later.
9. Install the cover plate by using the (3) #8x1/4 phillips head screws, taking care that the rubber gasket is positioned
properly.
10. Install the push-to-connect fitting that previously connected to the bubbler to the stem which is attached to the cover plate.
11. Reinstall the lower bowl cover with the (4) screws, making sure it is slid to the frontmost position before installing the
screws using a low amount of torque.
12. Repeat steps 6-11 for the high (left) side unit if applicable.
13. Reconnect power to the unit.
C. REINSTALLATION AND REACTIVATION OF THE BUBBLER
Reverse the steps above, taking care that the power is off while working inside of the bowl area. Flush
water through the bubbler for at least five minutes prior to use.
© 2020 Haws
®