Installation Sheet
07/17 Models 3600/3601/3602/3603/3610/3611/3612/3620/3621/3630/3601FR/
Page 3 of 10
3602FR/3603FR/3610FR/3611FR/3612FR/3620FR/3621FR/3630FR
TROUBLESHOOTING
PROBLEM
REPAIR CHECKLIST
1.
Insufficient bubbler flow
(3680/3680FR Drinking Fountain)
1a.
Verify minimum 30 psi flowing supply
pressure.
b.
For 3680- Check that inlet screwdriver
stop valve is wide open. Clean inlet
strainer or adjust valve to increase
flow. See 5874 Series Valve Manual.
c.
For 3680FR- Adjust valve to increase
flow. See 6518FR Manual.
2.
Insufficient bottle filler flow
(3690/3690FR Bottle Filler)
2a.
b.
c.
Nozzle strainer is clogged. Use nozzle
removal tool to remove strainer and
replace. Replacement strainers may be
ordered by calling Customer Service.
For 3690- Check that inlet screwdriver
stop valve is wide open. Clean inlet
strainer or adjust valve to increase
flow. See 5874 Series Valve Manual.
For 3690FR- Adjust valve to increase
flow. See 6518FR Manual.
For more information about Haws products, see our website: www.hawsco.com
© 2017 Haws
®
Corporation – All Rights Reserved
HAWS
®