User's Manual

5
OPERATION
Operation - all models
The wireless remote display/keypad communicates with the base receiver on the
Aqua Logic control unit using RF (radio frequency) technology. All of the display
information is transmitted from the Aqua Logic control unit to the wireless remote
display/keypad and all the button press information is transmitted by the wireless
remote display/keypad unit back to the Aqua Logic control unit.
If the display information is not being updated on a regular basis or if the Aqua Logic
is not responding to buttons being pressed, then refer to the Troubleshooting sec-
tion for assistance in resolving these problems.
When power is turned on to Wall Mount models, or when the Table Top models
"wake up", all the LED indicators will flash briefly, the display backlight will illuminate,
and the following display will appear for a short period of time:
The "r2.00" is the software revision level. The actual revision level for your wireless
remote display/keypad may be different. Refer to the Aqua Logic Operation Manual
for complete operating instructions.
Operation - AQL2-Tx-RF-PS-x Table Top models
Because the AQL2-Tx-RF-PS-x is battery operated, it displays various information
about its condition and the status of its batteries. Refer to the section below for an
explanation of these displays:
Shutting down to
save battery power
After one minute of no button presses, the AQL2-Tx-RF-PS-x will briefly show this
display and go into "sleep" mode. This mode conserves the battery power while the
remote is not in use. While asleep, all lights and the display will be off. To "wake" the
unit up, push any button on the keypad.
Refreshing display
When the AQL2-Tx-RF-PS-x "wakes" up, it will show this display while it collects
status information from the Aqua Logic control unit.
Please plug in to
charge battery
When the batteries are low, the Table Top unit will alternate between this display and
the normal status display. Under typical conditions, there are at least 50 more one-
minute uses available when this display is first shown. The batteries will slowly lose
charge if the unit is not plugged into the wall, even if it is not used.
Batteries dead!
Please charge now!
This display is shown briefly, immediately before the unit shuts down. The AQL2-Tx-
RF-PS-x will not operate again (to protect the batteries) until it is plugged into the
charger. It can be used immediately while connected to the charger.
TROUBLESHOOTING
1. Can’t find the "Teach Wireless" display: From the Aqua Logic control (or any
direct wired display/keypad) press the "menu" button (possibly more than once)
until "Settings Menu" is displayed. Next, press the "<" or ">" buttons (possibly
more than once) until the "Teach Wireless" display appears. If you get to the
point where "Settings Menu" appears again, then this means that the Aqua
Logic control unit is not communicating with the base receiver. Check that the 4
wire cable from the base receiver is plugged into the "wireless" connector on the
main printed circuit board. If this connector is already plugged in (for more than
30 seconds), then call Goldline Technical Service for assistance.
2. "Teach Wireless" failed: Ensure that the remote is powered when pressing the
button. This is indicated by any message on the display of the remote. If the
remote is powered, then the next most likely cause is that the distance between
the base receiver and the remote is too great—try moving the remote closer to the
receiver. Lastly, there may be other equipment in the neighborhood that is using
the same frequency. To see if this is the case, go to the Settings Menu/Wireless
Channel and select another channel. Note that after you change the channel you
will have to "re-teach" every wireless remote device in the system.
3. Unreliable communication with remote devices: The most likely cause is that
the distance between the base receiver and the remote is too great—try moving
the remote closer to the receiver. Lastly, there may be other equipment in the
neighborhood that is using the same frequency. To see if this is the case, go to
the Settings Menu/Wireless Channel and select another channel. Note that after
you change the channel you will have to "re-teach" every wireless remote device
in the system.
4. Wireless display/keypad not functioning (no display, no LEDs illuminated):
AQL2-Wx-RF-PS-x models: If the display/keypad located on the main unit is
working correctly, check that there is input power to the wireless display/key-
pad. Make sure that the wall mount power supply is plugged into an active
120VAC outlet and its output connector is plugged into the wireless remote
display/keypad.
AQL2-Tx-RF-PS-x models: If the display/keypad located on the main unit is
working correctly, check that there is input power to the wireless display/key-
pad. Plug the charger into an active 120VAC outlet and its output connector into
the wireless remote display/keypad. If this doesn't work, plug charger into the
unit, plug the charger into an active 120VAC outlet, wait 5 seconds, unplug the
charger, wait 5 seconds, and then plug it back in again.
6
Goldline Aqua Logic
RF Display r2.00