Instructions / Assembly

Note: Wire the pump directly to the timeclock -- do not use the AquaRite as a junction box.
AquaRite
AquaRite
Wiring
Power must be shut off at the circuit breaker before performing any wiring. Be sure to follow Local and
NEC electrical codes. To provide safe operation, the AquaRite must be properly grounded and bonded.
Input power for stand alone operation:
AQR15, AQR9, AQR3 - Wire the AquaRite to the LOAD SIDE of the filter pump timer.
Refer to the wiring label on the AquaRite as well as the diagram below to determine correct wiring
connections. The AquaRite is shipped from the factory with the configuration jumpers in 240VAC
position. If using 120VAC, move the jumpers as shown below. For Canadian models, the AquaRite
shall be connected to a circuit protected by a class A ground fault interrupter. Be sure to connect the
ground wire to the green ground screw terminal located on the bottom of the enclosure.
AQR15-120 - The AQR15-120 is designed to use 120 VAC only. The 120 VAC line cord must be
plugged into a GFCI receptacle or a receptacle protected by a Class A ground fault interruptor. See
diagram below.
Bonding: A lug used for bonding is attached to the bottom of the AquaRite enclosure (see diagram
below). The AquaRite must be bonded with an 8 AWG copper wire (6 AWG Canada) to the pool
bonding system.
Electrolytic Cell and Flow Switch: The electrolytic cell and flow switch cables are terminated with
connectors which plug into the AquaRite, for easy attachment and removal. The door of the AquaRite
Aqua Rite
SUBPANEL
GROUND
NEUTRAL
GFCI
OUTLET
BONDING
LOOP
PUMP
13
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS