Instructions / Assembly

Flowswitchconnector
Bondinglugto
pool bonding system
Cutoutfor
cell cable
must be open to access the cell cable connector. The flow switch plugs into a connector (similar to a
telephone jack) located outside, on the bottom of the enclosure. Refer to the diagram below for the
location of these connections.
Input power for use with Hayward, Pentair and Polaris controls
AQR15, AQR9, AQR3 - Wire the AquaRite directly to 120/240VAC power (not through timer or relay).
AQR15-120 - Input wiring is the same as "stand alone operation" on page 13.
Optional Hayward, Pentair and Polaris controls:
The Hayward, Pentair and Polaris controls use a 4 wire connection to communicate to the AquaRite
and can be wired up to 500' apart. Any outdoor rated 4 conductor cable can be used. Refer to
each manufacturer's instructions and the wiring diagrams below for proper wiring connection to the
AquaRite. NOTE: There must be only 1 "primary" unit. All other AquaRite units must be configured
as "secondary".
SUBPANEL
AQUARITE
(240 VAC)
AQUARITE
(120 VAC)
HAYWARD,
PENTAIR
or
POLARIS
PCB
PCB
BONDING
LOOP
BONDING
LOOP
GROUND
NEUTRAL
GND
GND
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS