Instructions / Assembly

2. "Generating" LED flashing
The temperature of the pool water is too high or low to operate. You can override this by switching
the main switch to SUPER CHLORINATE. The AquaRite will run at maximum output for the remainder
of the current pump cycle or 24 hours, whichever comes first.
3. "No Flow" LED illuminated
The AquaRite has sensed a no flow condition and has stopped generating chlorine. Check that the
flow switch is plugged into the connector on the bottom of the control unit and that the wire is not
cut or damaged. Make sure you have at least 12" of straight pipe before the flow switch. If there
is adequate flow and the LED is still on, check that the arrows on the flow switch (on top of hex) are
pointing in the direction of flow.
4. "Check Salt" LED illuminated or flashing
Be sure that the correct model Turbo Cell has been selected (page 8).
Check salt level in pool/spa. If salt level is low, add salt according to chart on page 5. Before adding
large quantities of salt, it is advisable to have your salt level professionally checked.
5. Salt Reading is a decimal number
If your default salt display screen is displaying a decimal number such as 3.20 rather than your usual
salt reading, such as 3200, it may have been switched to displaying in metric mode (g/L). To switch
back to displaying in ppm, perform the following:
• Press the Diagnostic Button one time.
• Slide your power switch from "Auto" to "Super Chlorinate" and back to "Auto".
• Wait 15 to 20 seconds. Your pool's salt level will once again be displayed in parts-per-million.
6. "High Salt" LED illuminated
Be sure that the correct model Turbo Cell has been selected (page 8).
Check salt level in pool/spa. If salt level is too high, lower salt level by draining some of the pool
water out of the pool and replace with fresh water. Continue until the salt concentration is at recom-
mended levels.
7. "Inspect Cell" LED flashing
Be sure that the correct model Turbo Cell has been selected (page 8).
Inspect and clean cell according to directions on page 10. When done, press the "diagnostic" button
for 3 seconds to stop the "Inspect Cell" LED flashing.
8. "Inspect Cell" LED illuminated
Be sure that the correct model Turbo Cell has been selected (page 8).
Remove and inspect the cell for scale. If the cell is scaled, follow the directions on page 10 for cell
cleaning. If the pool has the proper amount of salt and the "Inspect Cell" LED is still illuminated, the
cell may be worn and need replacement.
9. Possible causes of little or no free chlorine residual
- AquaRite switch in OFF position.