Submittal Sheet

Table Of Contents
60 80 100 120 140 160 180 200 220 240 260
WORKING PRESSURE (PSI)
TEMPERATURE ºF
160
140
120
100
80
60
40
20
0
HAYWARD
TIGHTEN
A
D
B
C
E
INNER SURFACE,
TANK WALL
WWW.HAYWARDFLOWCONTROL.COM 1.888.429.4635
Hayward is a registered trademark and Tank-Tite
is a trademark of Hayward Industries, Inc.
© 2015 Hayward Industries, Inc.
Contact Hayward Flow Control with questions: USA: 1-888-429-4635 • Fax: 1-888-778-8410 • One Hayward Industrial Drive • Clemmons, NC 27012 USA
Canada: 1.888.238.7665 • Fax: 1.905.829.3636 • 2880 Plymouth Drive • Oakville, ON L6H 5R4 Canada • Email: hflowcanada@haywardnet.com
Visit us at: www.haywardflowcontrol.com • E-mail: hflow@haywardnet.com
94
TECHNICAL INFORMATION, CONTINUED
BFA Series Bulkhead
Fittings – Standard Flange
1/2˝ TO 6˝ PVC, CPVC AND PP – LONG PATTERN
MINIMUM INSIDE RADII OF TANKS FOR
BULKHEAD FITTING INSTALLATION
DIMENSIONS
SIZE
in/DN
A
in/mm
B
in/mm
C
in/mm
D
in/mm
E
in/mm
ACROSS FLATS INSTALLATION HOLE SIZE ACROSS FLATS GASKET THICKNESS
1/2/15 2.00/51 3.75/95 1.38/35 2.00/51 .19/5
3/4/20 2.38/60 3.88/99 1.63/41 2.38/60 .19/5
1/25 2.56/65 3.88/99 1.88/48 2.56/65 .19/5
1-1/4/32 3.25/83 4.00/102 2.65/67 3.25/83 .19/5
1-1/2/40 3.25/83 4.00/102 2.65/67 3.25/83 .19/5
2/50 4.38/111 4.25/108 3.25/83 4.38/111 .25/6
3/80 6.00/152 4.65/118 4.50/114 6.00/152 .25/6
4/100 8.75/222 5.75/146 5.75/146 8.75/222 .25/6
6/150 12.00/305 8.00/203 8.06/205 12.00/305 .31/8
Dimensions are subject to change without notice – consult factory for installation information
Dimensions A and D are Across Flats. 1/2˝ to 2˝ Hexagon Flats, 3˝, 4˝ and 6˝ Octagon Flats
SIZE
in/DN
Min. Rigid
Tank Radius
Min. Flexible
Tank Radius
Max. Wall
Thickness
1/2/15 7.25˝ 6.50˝ 2.08˝
3/4/20 10.00˝ 9.25˝ 2.08˝
1/25 11.75˝ 10.70˝ 2.08˝
1-1/4/32 16.25˝ 12.19˝ 2.00˝
1-1/2/40 16.25˝ 12.19˝ 2.00˝
2/50 25.75˝ 19.38˝ 2.00˝
3/80 30.00˝ 25.25˝ 2.12˝
4/100 60.00˝ 55.00˝ 2.45˝
6/150 114.00˝ 97.00˝ 3.25˝
OPERATING TEMPERATURE/PRESSURE