Figure 36: ERROR CODES
TCM ERROR CODES:
Note: If two or more faults are present at the same time, the error code highest on the
following table will be displayed.
Code Description Information
LO
Limit string open
while call-for-heat
If the string of limit switches opens while there is a call-for-heat, the heater will
shutdown and go into lock-out. Automatic restart 2 minutes after the limit string
error condition is corrected.
SF Thermistor fault
An excessive temperature difference between the two thermistors (3°C or more)
or an “out of bounds” condition on either sensor (temperature less than 2°C or
greater than 82°C). The heater will shut down and go into lock-out. Automatic
restart 2 minutes after the thermistor error condition is corrected.
HE
Rapid water
temperature rise
If water temperature rises too rapidly in two consecutive 10-second periods, the
heater will shut down and go into lock-out. Automatic restart after 2 minutes.
After the third occurrence in the same call-for-heat, the heater will go into lock-
out with automatic restarts disabled. Manual restart is required.
HS
Excessive Water
Temperature
Inlet water temperature sensor is reporting a temperature in excess of 40°C.
Normal operation resumes 2 minutes after inlet water temperature sensor reports
temperatures of 40°C or less. This error functions in both normal and remote
thermostat modes.
lo
Limit string open while
no call-for-heat
If the string of limit switches opens while there is no call-for-heat, the error code
will be displayed, but the control will continue to function. The error code will
be cleared when the condition is corrected.
Sb
Keypad button
stuck closed
If one of the keypad buttons is closed (pressed) for more than 30 seconds, the
error code will be displayed but the control will continue to function. The error
code will be cleared when the condition is corrected.
bo Bypass Operation mode
This is NOT an error code. If the user sees “bo” in the display, the TCM is in
Bypass Operation mode. To exit “Bypass Operation” mode, select “STANDBY”
mode, then press and hold both the “DOWN” and “MODE” buttons for 3 sec-
onds (until the “bo” code is no longer displayed).
. (dot) Auto restarts disabled
When a dot (decimal point) is displayed after the error code, this is an indication
that auto restarts are disabled. The TCM must be manually restarted.