GAS SUPPLY INSTALLATION:
The heater is shipped from the factory with the gas connection
located on the left-hand side of the heater cabinet. Insert the pipe to
the gas valve through the grommet in the cabinet side (see Figure
18.) A union should be installed outside the heater cabinet for easy
removal of the gas manifold assembly during service.

the cabinet and within 6 feet of the heater. This valve must have an
I.D. large enough to supply the proper amount of gas
volume to the heater. See Figure 17.
ATTENTION: Apply joint compound (pipe dope)
sparingly and only to the male threads of pipe joints.

Use joint compounds resistant to the action of lique-

pipe or damage may result.
ATTENTION : -
nectors on any gas connections unless the connector

with BTUH capacity (which must be equal to or
greater than the heater rated input) and the type of gas
(natural or LP).
Reduction of gas supply pipe or tubing to the inlet of

If more than one appliance is installed on the gas line, consult the local gas company for the proper gas
line size.
Questions on the installation of the proper gas line size can be directed to Hayward Technical Service.
NATURAL GAS:
The gas meter must have the capacity to supply enough gas to the pool heater and any other gas appli-
ances if they are on the same pipeline (Example: 225 meter = 225,000 BTUH). If doubt exists as to the meter
size, consult the local gas utility for assistance. Hayward will not be responsible for heaters that soot up due
to improper meter and gas line sizing resulting in improper gas volume.
PROPANE GAS:
h

codes. If the propane gas tank is installed underground, the discharge of the regulator vent must be above the
highest probable water level.


Figure 17
Gas
Inlet
Supply
voltage
inlet
Low
voltage
inlet
Bonding
lug
Figure 18