User Guide
415
Gallons and (Liters) of Pool/Spa water
12,000 14,000 16,000 18,000 20,000 22,000 32,00024,000 34,00026,000 36,00028,000 38,00030,000 40,000
Current salt
level
(45000) (52,500) (60,000) (67,500) (75,000) (82,500) (120,000)(90,000) (127,500)(97,500) (135,000)(105,000) (142,500)(112,500) (150,000)ppm
0
320
(145)
373
(170)
427
(194)
480
(218) (242)
587 854
(267) (388)
640 907
(291) (412)
693 960
(315) (436)
747
(339) (460)
800 1067
(364) (484)
200
300
(136)
350
(159)
400
(182)
450
(205)
500
(227)
550 800
(250)
(363)
600 850
(273) (385)
650 900
(295) (408)
700 950
(318) (430)
750 1000
(341) (453)
400
280
(127)
327
(148)
373
(170)
420
(191)
467
(212)
513 747
(233) (339)
560 793
(255) (360)
607 840
(276) (382)
653 887
(297) (403)
700 933
(318) (424)
600
260
(118)
303
(138)
347
(158)
390
(177)
433
(197)
477 693
(217) (317)
520 737
(236) (337)
563 780
(256) (358)
607 823
(276) (378)
650 867
(297)
(398)
800
240
(109)
280
(127)
320
(145)
360
(164)
400
(182)
440 640
(200) (291)
480 680
(218) (310)
520 720
(236) (328)
560 760
(255) (346)
600 800
(273) (364)
1000
220
(100)
257
(117)
293
(133)
330
(150)
367
(167)
403 587
(183) (267)
440 623
(200) (283)
477 660
(217) (300)
513 697
(233) (317)
550 733
(250) (333)
1200
200
(91)
233
(106)
267
(121)
300
(136)
333
(152)
367 533
(167) (243)
400 567
(182) (258)
433 600
(197) (274)
467 633
(212) (289)
500 667
(227) (304)
1400
180
(82)
210
(95)
240
(109)
270
(123)
300
(136)
330 480
(150) (218)
360 510
(164) (232)
390 540
(177) (246)
420 570
(191) (259)
450 600
(205) (263)
1600
160
(73)
187
(85)
213
(97)
240
(109)
267
(121)
293 427
(133)
(195)
320 453
(145) (207)
347 480
(158) (219)
373 507
(170) (231)
400 533
(182) (243)
1800
140
(64)
163
(74)
187
(85)
210
(95)
233
(106)
257 373
(117) (169)
280 397
(127) (180)
303 420
(138) (190)
327 443
(148) (201)
350 467
(159) (211)
2000
120
100
80
60
20
40
(55)
(45)
(36)
(27)
(9)
(18)
140
117
23
47
(64)
(53)
(11)
(21)
160
133
27
53
(73)
(61)
(12)
(24)
180
150
30
60
(82)
(68)
(14)
(27)
200
167
33
67
(91)
(76)
(15)
(30)
220 320
183 267
37 53
73 107
(100) (145)
(83) (121)
(17) (24)
(33) (48)
240
340
200 283
40
57
80 113
(109) (154)
(91) (129)
(18) (26)
(36) (51)
260 360
217 300
43 60
87 120
(118) (163)
(98) (137)
(20) (27)
(39) (54)
280 380
233 317
47
63
93
127
(127) (172)
(106) (144)
(21) (29)
(42) (57)
300 400
250 333
50
67
100 133
(136) (181)
(114) (152)
(23) (30)
(45) (60)
(32)
80
(36)
90
(41)
100
(45)
110 160
(50) (73)
120 170
(55) (77)
130 180
(59) (81)
140
190
(64) (86)
150 200
(68) (90)
93
(42)
107
(48)
120
(55)
133
(61)
147 213
(67) (98)
160
227
(73) (104)
173 240
(79) (110)
187 253
(85) (117)
200
267
(91) (123)
2200
3000
2800
2400
3200
Ideal Ideal Ideal Ideal Ideal Ideal IdealIdeal IdealIdeal IdealIdeal IdealIdeal Ideal
2600
3400
OK
OK
OK
OK
OK OK OK OK OKOK OKOK OKOK OKOK OK
POUNDS and (Kg) OF SALT NEEDED FOR 3200 PPM
3600+
Dilute Dilute Dilute Dilute Dilute Dilute DiluteDilute DiluteDilute DiluteDilute DiluteDilute Dilute
10,000 8,000
(37,500)
213
267
(97)
(121)
200 250
(91) (114)
187 233
(85)
(106)
173
217
(79) (98)
160 200
(73)
(91)
147 183
(67) (83)
133 167
(61) (76)
120 150
(55) (68)
107 133
(48) (61)
93 117
(42) (53)
80 100
67 83
53
67
40 50
13 17
27 33
(36) (45)
(30) (38)
(24) (30)
(18) (23)
(6) (8)
(12)
(15)
Ideal Ideal
Dilute Dilute
(30,000)
Bonding lug to pool
bonding system
Second bonding lug for
Canadian models only
Cutout for
cell cable
Bottom of
Aqua Rite Pro Enclosure
Electrolytic Cell: Install using the unions provided. Tighten unions BY HAND for a
watertight seal. For pool/spa combination systems with spillover,
use configurations #2 or #3 above to allow chlorination of both the
pool and spa during spillover but preventing overchlorination when
operating the spa only.
Wiring
Power must be shut off at the circuit breaker before performing any wiring. Be sure to
follow Local and NEC electrical codes. To provide safe operation, the Aqua Rite Pro
must be properly grounded and bonded.
Input Power:
Wire the Aqua Rite Pro to the LOAD SIDE of the filter pump timer. It is very important
that the Aqua Rite Pro is powered only when the pump is running. Note that this circuit
must be protected by a Ground Fault Circuit Breaker (GFCB).
Refer to the wiring label on the Aqua Rite Pro as well as the diagram below to determine
correct wiring connections. The Aqua Rite Pro is shipped from the factory with the
configuration jumpers in 240VAC position. If using 120VAC, move the jumpers as
shown below. IMPORTANT: If a dispensing device will be used (page 17), it must be
powered by the same input voltage as the Aqua Rite Pro.
For Canadian models, the Aqua Rite Pro shall be connected to a circuit protected by a
class A ground fault interrupter. Be sure to connect the ground wire to the green ground
screw terminal located on the bottom of the enclosure.
Bonding:
A lug used for bonding is attached to the bottom of the Aqua Rite Pro enclosure (two
lugs are provided for Canadian models). The Aqua Rite Pro must be bonded with an 8
AWG copper wire (6 AWG Canada) to the pool bonding system. Refer to the diagram
below.
SUBPANEL
TIMECLOCK
AQUA
RITE Pro
AQUA
RITE Pro
PCB
GND
PCB
BONDING
LUG
BONDING
LOOP
PUMP
LINELOAD
GROUND
IMPORTANT:
MOVE JUMPERS
TO POSITIONS SHOWN
TYPICAL 240 VAC WIRING120 VAC
Note: Wire the pump directl
y
to the timeclock--do not use the Aqua Rite Pro as a
j
unction box.