PureLine Replacement Aqua Rite Main PC Board PL7100 (GLXPCBRITE)
Page 1 SAVE THIS INSTRUCTION MANUAL ATTENTION INSTALLER : This manual contains essential information about the installation, operation, and safe use of this Main PC Board. Please remember to furnish this manual and all other instructional documents to the end user of this product. The PureLine PC Board is specifically engineered to work with s pecific models of the Hayward Aqua Rite Salt Systems. Verify if this board is compatible with your model before installing the product.
Page 2 General Information This manual contains essential information about the installation, operation, and safe use of the PureLine PC Board. Failure to install according to the defined instructions can void your warranty. The PureLine PC Board is a replacement for your original Goldline Control Hayward Aqua Rite PC Board. It is compatible with most Aqua Rite control panels or models. Please refer to the compatibility section before performing the installation.
Page 3 Product Dimensions INYOPOOLS.
Page 4 Product Compatibility ● Hayward AquaRite ● Goldline Aquarite ● BioGuard Mineral Springs ● SwimPure Plus ● Replaces the Hayward GLXPCBRITE Main PC Board Automatic Controls The PureLine PC board will not link with any automatic control system your pool system may currently have. Automation systems allows pool owners to control different pool features from any location.
Page 5 Wiring and Installation WARNING TURN OFF POWER TO TIMER BOX FIRST. Failing to turn off power before removing your current board can result in electrocution or death. Things You Will Need For Installation: ● Main Aqua Rite PC Board ● 5/16” socket 1. Make sure power is OFF. 2. Unplug the cell cord and the flow switch from the control box. 3. Using a 5/16“ socket, remove the two screws that secure the cover panel to the Aqua Rite control box. 4.
Page 6 16. Using the metal jumpers provided, finish wiring the board. Please refer to the label on the inside door of the Aqua Rite control box or the picture to the right for the jumper locations. You can also verify what voltage you are using by looking at the jumper locations on your old board. 17. Press the Display Board back onto the new PureLine Main PC Board. Ensure the long pins from the Main PC Board match with the holes on the Display PC Board. 18. Place the control box cover back onto the box.
Page 7 3. Switch unit from OFF to AUTO, then to SUPER CHLORINATE 4. Keep toggling between AUTO and SUPER CHLORINATE. Repeat this step until the correct cell size is displayed. Recalibrating the Cell Occasionally, the salt level on the Aqua Rite system may not match the actual salt level of the pool. If your salt cell is clean, but the reading is off, the Aqua Rite system may need to be recalibrated. The following steps will help calibrate your system. 1. Turn the system OFF, then to AUTO. 2.