User Manual

Page6
16. Usingthemetaljumpersprovided,finishwiringtheboard.
PleaserefertothelabelontheinsidedooroftheAqua
Ritecontrolboxorthepicturetotherightforthe
jumperlocations.Youcanalsoverifywhatvoltageyou
areusingbylookingatthejumperlocationsonyourold
board.
17. PresstheDisplayBoardbackontothenewPureLineMain
PCBoard.EnsurethelongpinsfromtheMainPCBoard
matchwiththeholesontheDisplayPCBoard.
18. Placethecontrolboxcoverbackontothebox.
19. Tightenthetwocoverscrewsusingthe5/16”socket.
20. TurnpowerONatthecircuitbreaker.ThePOWERlightand
thedisplayshouldlightupifeverythingisoperating
correctly.
**IMPORTANT**
SaltReadings:ChangingfromtheMetricSystem
toPartsPerMillion(PPM)
Whenyoupoweronyoursystem,youwillneedtochangethecalibrationreadingsfromthe
Metricsystemtoreadpartspermillion(PPM).Failuretodosocanresultinfalsesaltreadings.
1. PresstheDiagnosticbuttonfive(5)timesuntilyousee“InstantSaltReading”
2. SwitchunitfromAUTOtoOFF
3. SwitchunitfromOFFtoAUTO,thentoSUPERCHLORINATE
4. SwitchunitbacktoAUTO
5. Yourdisplayshouldnowreadthesaltlevelinpartspermillion(PPM).
*Thesaltlevelmayneedtobecalibrated.PleaserefertotheCalibrationsectionbelow.*
SelectingCorrectCellSize
Inordertoattainaccuratesaltreadings,pleaseensurethatyournewboardissettothecorrect
cellsizeofyoursaltsystem.
1. PresstheDiagnosticbuttoneight(8)timesuntilthecellsizeappears(T3,T5,T9,or
T15)
2. SwitchunitfromAUTOtoOFF