User Manual
Gall
o
n
s
a
n
d
(
L
i
t
e
r
s
)
o
f
P
o
o
l
/
S
p
a
w
a
t
e
r
12,000 14,000 16,000
1
8
,
0
0
0
2
0
,
0
0
0
2
2
,
0
0
0
3
2
,
0
0
0
2
4
,
0
0
0
3
4
,
0
0
0
2
6
,
0
0
0
3
6
,
0
0
0
2
8
,
0
0
0
3
8
,
0
0
0
3
0
,
0
0
0
4
0
,
0
0
0
Current salt
level
(45000) (52,500) (60,000)
(
6
7
,
5
0
0
)
(
7
5
,
0
0
0
)
(
8
2
,
5
0
0
)
(
1
2
0
,
0
0
0
)
(
9
0
,
0
0
0
)
(
1
2
7
,
5
0
0
)
(
9
7
,
5
0
0
)
(
1
3
5
,
0
0
0
)
(
1
0
5
,
0
0
0
)
(
1
4
2
,
5
0
0
)
(
1
1
2
,
5
0
0
)
(
1
5
0
,
0
0
0
)
ppm
0
320
(145)
373
(170)
427
(194)
4
8
0
(
2
1
8
)
(242)
587 854
(267) (388)
640 907
(291) (412)
693 960
(315) (436)
747
(339) (4
6
0
)
800
1
0
6
7
(364)
(
4
8
4
)
200
300
(136)
350
(159)
400
(182)
450
(205)
500
(227)
550 800
(250)
(363)
600 850
(273) (385)
650 900
(295) (408)
700 9
5
0
(318) (4
3
0
)
750
1
0
0
0
(341)
(
4
5
3
)
400
280
(127)
327
(148)
373
(170)
420
(191)
467
(212)
513 747
(233) (339)
560 793
(255) (360)
607 840
(276) (382)
653 8
8
7
(297) (4
0
3
)
700
9
3
3
(318)
(
4
2
4
)
600
260
(118)
303
(138)
347
(158)
390
(177)
433
(197)
477 693
(217) (317)
520 737
(236) (337)
563 780
(256) (358)
607 8
2
3
(276) (3
7
8
)
650
8
6
7
(297)
(
3
9
8
)
800
240
(109)
280
(127)
320
(145)
360
(164)
400
(182)
440 640
(200) (291)
480 680
(218)
(310)
520 720
(236) (328)
560 76
0
(255) (3
4
6
)
600
8
0
0
(273)
(
3
6
4
)
1000
220
(100)
257
(117)
293
(133)
330
(150)
367
(167)
403 587
(183) (267)
440 623
(200) (283)
477 660
(217) (300)
513 69
7
(233) (3
1
7
)
550
7
3
3
(250)
(
3
3
3
)
1200
200
(91)
233
(106)
267
(121)
300
(136)
333
(152)
367 533
(167) (243)
400 567
(182) (258)
433 600
(197) (274)
467 63
3
(212) (2
8
9
)
500
6
6
7
(227)
(
3
0
4
)
1400
180
(82)
210
(95)
240
(109)
270
(123)
300
(136)
330 480
(150) (218)
360 510
(164) (232)
390 540
(177) (246)
420 57
0
(191) (2
5
9
)
450
6
0
0
(205)
(
2
6
3
)
1600
160
(73)
187
(85)
213
(97)
240
(109)
267
(121)
293 427
(133)
(195)
320 453
(145) (207)
347 480
(158) (219)
373 50
7
(170) (2
3
1
)
400
5
3
3
(182)
(
2
4
3
)
1800
140
(64)
163
(74)
187
(85)
210
(95)
233
(106)
257 373
(117) (169)
280 397
(127) (180)
303 420
(138) (190)
327 44
3
(148) (20
1
)
350
4
6
7
(159)
(
2
1
1
)
2000
120
100
80
60
20
40
(55)
(45)
(36)
(27)
(9)
(18)
140
117
23
47
(64)
(53)
(11)
(21)
160
133
27
53
(73)
(61)
(12)
(24)
180
150
30
60
(82)
(68)
(14)
(27)
200
167
33
67
(91)
(76)
(15)
(30)
220 320
183 267
37 53
73 107
(100) (145)
(83) (121)
(17) (24)
(33) (48)
240
340
200 283
40
57
80 113
(109) (154)
(91) (129)
(18) (26)
(36) (51)
260 360
217 300
43 60
87 120
(118) (163)
(98) (137)
(20) (27)
(39) (54)
280 38
0
233 31
7
47
6
3
93
1
2
7
(127) (17
2
)
(106) (1
4
4
)
(21) (2
9
)
(42) (5
7
)
300
4
0
0
250
3
3
3
50
6
7
100
1
3
3
(136)
(
1
8
1
)
(114)
(
1
5
2
)
(23)
(
3
0
)
(45)
(
6
0
)
(32)
80
(36)
90
(41)
100
(45)
1
1
0
1
6
0
(
5
0
)
(
7
3
)
1
2
0
1
7
0
(
5
5
)
(
7
7
)
1
3
0
1
8
0
(
5
9
)
(
8
1
)
1
4
0
1
9
0
(
6
4
)
(
8
6
)
1
5
0
2
0
0
(
6
8
)
(
9
0
)
93
(42)
107
(48)
120
(55)
133
(61)
1
4
7
2
1
3
(
6
7
)
(
9
8
)
1
6
0
2
2
7
(
7
3
)
(
1
0
4
)
1
7
3
2
4
0
(
7
9
)
(
1
1
0
)
1
8
7
2
5
3
(
8
5
)
(
1
1
7
)
2
0
0
2
6
7
(
9
1
)
(
1
2
3
)
2200
3000
2800
2400
3200
Ideal Ideal Ideal Ideal Ideal
I
d
e
a
l
I
d
e
a
l
I
d
e
a
l
I
d
e
a
l
I
d
e
a
l
I
d
e
a
l
I
d
e
a
l
I
d
e
a
l
I
d
e
a
l
I
d
e
a
l
2600
3400
OK
OK
OK
OK
OK OK OK
O
K
O
K
O
K
O
K
O
K
O
K
O
K
O
K
O
K
O
K
P
O
U
N
D
S
a
n
d
(
K
g
)
O
F
S
A
L
T
N
E
E
D
E
D
F
O
R
3
2
0
0
P
P
M
3600+
Dilute Dilute Dilu
t
e
D
i
l
u
t
e
D
i
l
u
t
e
D
i
l
u
t
e
D
i
l
u
t
e
D
i
l
u
t
e
D
i
l
u
t
e
D
i
l
u
t
e
D
i
l
u
t
e
D
i
l
u
t
e
D
i
l
u
t
e
D
i
l
u
t
e
D
i
l
u
t
e
10,000
8,000
(37,500)
213
267
(97)
(121)
200 250
(91) (114)
187 233
(85)
(106)
173
217
(79)
(98)
160 200
(73)
(91)
147 183
(67) (83)
133 167
(61) (76)
120 150
(55) (68)
107 133
(48) (61)
93 117
(42) (53)
80 100
67 83
53
67
40 50
13 17
27 33
(36) (45)
(30) (38)
(24) (30)
(18) (23)
(6) (8)
(12)
(15)
Ideal
Ideal
Dilute
Dilute
(30,000)
3
The pool’s chemistry must be balanced BEFORE activating the Aqua Plus’s optional chlorinator function. NOTE: If
the pool does not have new water, add metal remover and non-copper based algaecide to the pool, per manufacturer’s
instructions. This ensures a quick, troublefree transfer to the Aqua Plus system.
Salt
Salt Level
Use the chart below to determine how much salt in pounds or (Kgs) should be added to reach the recommended
levels. Use the Pool Sizing Formula on page 4 (measurements are in feet/gallons and meters/liters) if pool size is
unknown.
The operating salt level is between 2700-3400 PPM (parts per million) with 3200 PPM being optimal. Before adding
any salt, test the salt level. This is especially important for retrofit installation to older pools where all of the chlorine
added to the pool over time is ending up as salt. If the level is low, determine the number of gallons in the pool and add
salt according to the chart below. A low salt level will reduce the efficiency of the sanitization and result in low chlorine
production. A high salt level can cause the Aqua Plus to stop chlorinating. The salt in your pool/spa is constantly
recycled and the loss of salt throughout the swimming season should be minimal. This loss is due primarily to the
addition of water because of splashing, backwashing, or draining (because of rain). Salt is not lost due to evaporation.
28
Valve3
Disabled
Freeze
Toggle between Enabled and Disabled (default) Valve3 Freeze
Move to previous/next configuration menu
for all functions except super chlorinate
Valve3 Config.
+ to view/change
Valve3 Function
Solar
Push to access Valve3 options
Rotates Timeclock (default), Solar, In-floor Cleaner and Super Chlorinate
Move to previous/next configuration menu
Move to next menu item
Valve3
Disabled
Interlock
Toggle between Enabled and Disabled (default) Valve3 Interlock
Move to next menu item
for all functions except solar and super chlorinate
for all functions except solar and super chlorinate
Valve3 Ext Input
Disabled
Toggle between Enabled and Disabled (default)
Move to previous/next configuration menu
if filter pump is set to variable speed
and the relay type is set to standard
Valve3 Pump Spd
Settings Menu
Select Settings Menu (default) or desired pump speed (Filter Lowest to Highest)
Move to previous/next configuration menu
Valve3 Function
Timeclock (default) – the valve turns on/off at the times set for the valve3 timeclock in the Timers Menu
(see Operations Manual). The VALVE3 button can also be used to turn the valve output on or off.
Solar – the valve operates when the filter pump is running and solar heat is available and the water is less
than the desired temperature setting. Solar heating must be enabled in the “Solar Config. menu for proper
operation to occur.
In-Floor Cleaner – the valve switches the water returning to the pool between the in-floor cleaner and the
normal return jets which facilitate efficient surface skimming. The valve will operate the in-floor cleaner for
the first half of each clock hour and then switch to the jets/skimming for the last half of the hour.
Super Chlorinate – if “Chlorinator” is enabled, this option allows the user to start a Super Chlorinate cycle
when the Valve3 button is pressed, rather than using the Settings Menu. Note that only one button can be
assigned to this function.
Valve3 Interlock
If “Enabled”, this feature will override the function (timeclock or in-floor cleaner) selected above and turn
the valve off when: the filter pump is off, first 3 minutes of filter pump operation (allows the pump to prime
and get water flowing), or for the first 3 minutes after solar turns on (allows air in the solar panels to be
purged). Interlock is not available for solar or super chlorinate.
Valve3 External Input Interlock
When Valve3 External Input Interlock is enabled, the Valve3 output will be forced off when the external
input is active. This will have precedence over freeze protection. Valve3 External Input Interlock is not
available for solar and super chlorinate.
Valve3 Freeze Protection
This function protects the pool and plumbed equipment against freeze damage. If Freeze Protection is
enabled and the AIR temperature falls sensor falls below the selected freeze temperature threshold, the
Aqua Plus will turn on the valve to allow circulation of the water. IMPORTANT: this only enables
operation of the valve3 output during freeze--see the “Filter Pump Config.” menu to enable freeze protection
for the main circulation system.
Valve3 Pump Speed
This is the speed of the pump when the Valve3 output is on. The default selection is “Settings Menu”.
This is the speed of the pump that has been selected in the Settings Menu for normal filter operation. If an
alternate speed is desired when the Valve3 output is on, push “+” or “-” and select from “Filter Lowest” to
“Filter Highest” in 5% increments.