Installation Guide
WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Super Pump
™
Series ___________________ ______________________________Page 10 of 15
Seal Installation (See Parts Diagram on page 11 of this manual for pump component locations.)
8. Clean and lightly lubricate the impeller hub and seal recess in the seal plate with a dilute solution of non-
granulated liquid-type soap.
9. Gently wipe the black, polished surface of the spring seal assembly with a clean, soft, cotton cloth. Press the
spring seal assembly onto the impeller hub – black polished surface facing away from the impeller.
10. Gently wipe the polished surface of the ceramic seal with a clean, soft, cotton cloth. Lubricate the rubber cup
on the ceramic seat and press it firmly and evenly into the recess of the seal plate – polished side facing out.
Replacing the Impeller and Diffuser (See Parts Diagram on page 11 of this manual for pump component locations.)
11. Place the seal plate onto the motor mounting plate, aligning the tabs on the seal plate with the grooves on the
motor mounting plate.
12. Screw the impeller onto the motor shaft in a clockwise direction. Tighten snugly by holding motor shaft with
wrench as noted in step #4.
13. Place the diffuser over the impeller onto the seal plate fitting positioning lug between the two (2) guides.
Replacing the Motor Assembly (See Parts Diagram on page 11 of this manual for pump component locations.)
14. Fasten motor end cover by using the two (2) hex shaped screws. Slide the motor assembly with the diffuser in
place, into pump/strainer housing, being careful not to disturb the diffuser gasket.
15. Fasten assembly to pump/strainer housing using the four (4) 3/8”" x 2" housing cap screws. (Be sure