User's Manual

Operating Instructions
Radio Transmitter micron 4 Industrial
BE-MICR4_I-V2-2.DOC [ Word 97 ] FL Page 9 / 18
HBC-radiomatic GmbH • D-74564 Crailsheim • GERMANY
Information and specifications subject to change without notice. 2000-08-15
Radio System
For safety reasons we have equipped the transmitter with an automatic switch-OFF. The
transmitter is automatically put out of circuit after 15 minutes of non-use.
The automatic switch-OFF also saves battery power.
Note:
The automatic switch-OFF does not relieve the operator of his responsibility to turn
OFF the transmitter when not in use !
The micron 4 can be reactivate by means of the "On/Horn“ pushbutton (refer to
illustration on page 8, pos. Â).
Scanner (Frequency Selector)
The transmitter and receiver are equipped with a "Scanner"
(frequency selector) operating mode with 4 radio
frequencies (refer to wiring diagrams).
In the event that a particular channel is being used by
another operator, the transmitter can be programmed to a
different channel by means of the rotary selector switch
located inside the transmitter. The receiver scanner
automatically adjusts the receiver to the selected radio
frequency.
Changing radio control system frequencies :
1. Switch OFF transmitter with "OFF" switch (turn switch
to “0” position).
2. Remove protective cap from the back of the
transmitter.
3. To select a new frequency, use a screwdriver (size 0)
and turn the switch clockwise (one step).
4. Replace protective cap.
5. Switch ON transmitter with "ON/Horn" switch (turn
switch to “1” position).
After turning ON the transmitter (do not forget to unlock
STOP pushbutton), the receiver automatically resets the
system to the new frequency selected in less than a
second.
Battery compartment
Remove
protection
cap first !
0 - 3
4 - 7
8 - B
C - F
= RF channel 1-4 with APO
= RF channel 1-4 without APO
= RF channel 1-4, customer, with APO
= RF channel 1-4, customer,
without APO
File:
micron4-I_APO-FrequenzWahl.CDR [ CorelDraw 8.0 ] 06-14-2000 FL
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F