User's Manual
Troubleshooting
Note:
Please check the functions using the cabin or cable controls first!
Problem Possible Cause Remedy
Transmitter does not react
when switched on.
No power. Check battery contacts for
damage or contamination.
Insert a fully charged battery
into the battery
compartment.
Recharge battery.
Low-power indication after
minimal operating time.
Battery contacts are
contaminated or damaged.
Battery not charged.
Battery defective.
Check battery contacts for
damage or contamination.
Recharge battery.
Ensure that recharging
process runs correctly.
Check transmitter functions
using a fully charged or
replacement battery.
The display in the transmitter
flashes green but it is not
possible to effect control
commands.
Receiver has no voltage.
No radio communication.
"Crane On" command has
not been given.
Check the connecting cable
to the receiver.
Check the functions via the
LEDs in the radio status
panel of the receiver.
Some commands are not
carried out.
Receiver defective.
Interruption in the
connecting cable to the
machine.
Check if all connecting
cables and cable junctions
are tight.
If none of the measures mentioned resolve the problem, then please contact your service technician,
dealer or HBC-radiomatic, Inc.