Third Party Verification Claim

Performance Data Sheet
fmL-1, fmL-2, fmL-3, fmm-1, fmm-2, fmS-1, fmS-2, fmW-2
This system has been tested according to NSF/ANSI Standard 42 and 53 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or
equal to the permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.
Substance
Percent
Reduction
Obtained
Minimum
Reduction
per
Standard
Average
Influent
Challenge
ug/L (ppb)
Maximum
Product Water
Concentration
Per Standard
ug/L (ppb)
Actual
Maximum
Obtained in
Testing
ug/L (ppb)
Chlorine
> 97%
50%
2.0 mg/L
1.0 mg/L
0.05 mg/L
Endrin
> 90%
66%
5.5
2
1
1,2,4-Trichlorobenze
> 99%
66%
215
70
0.7
p-dichlorobenze
> 99%
66%
225
75
0.5
Carbon Tetrachloride
> 95%
66%
14
5
1.3
Tetrachloroethylene
> 96%
64%
14
5.0
0.5
Unsym-Trichlorobenzene
(see 1,2,4-
TRICHLOROBENZENE)*
> 99%
66%
215
70
0.7
PCE (see
Tetrachloroethylene)
> 96%
64%
14
5.0
0.5
Note: Testing was performed under standard laboratory conditions, actual performance may vary.
System to be used with municipal or well water sources treated and tested on regular basis to ensure bacteriological safe
quality. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before
or after the system.
It is essential that the manufacturer’s recommended installation, maintenance and filter replacement requirements be
carried out for the product to perform as advertised. See installation manual for warranty information.
US Based Customer Service 855-849-3589
Filter Specifications
Flow Rate
Operating
Temperature
Operating Pressure
Capacity