Third Party Verification Claim

Performance Data Sheet
fmW-5
This system has been tested according to NSF/ANSI Standard 42 and 53 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or
equal to the permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.
Substance
Percent
Reduction
Obtained
Minimum
Reduction
per
Standard
Average
Influent
Challenge
ug/L (ppb)
Maximum
Product Water
Concentration
Per Standard
ug/L (ppb)
Actual
Maximum
Obtained in
Testing
ug/L (ppb)
Chlorine
50%
2.0
mg/L
1.0
mg/L
0.05
mg/L
Benzene
66
%
15
5
0.5
Carbofuran
50%
80
40
1.3
Endrin
> 9
5
%
66%
5
.
5
2
1
p-dichlorobenze
66%
225
75
0.5
Toxaphene
> 9
3
%
80
%
15
3
0.7
Note: Testing was performed under standard laboratory conditions, actual performance may vary.
System to be used with municipal or well water sources treated and tested on regular basis to ensure bacteriological safe quality. Do
not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
It is essential that the manufacturer’s recommended installation, maintenance and filter replacement requirements be carried out
for the product to perform as advertised. See installation manual for warranty information.
US Based Customer Service – 855-849-3589
Additional Information available at:
www.homedepot.com/p/206181225
www.homedepot.com/p/206181239
Filter Specifications
Flow Rate 0.5 gpm / 1.89 lpm
Operating Temperature 33 - 100°F (0.6°C - 38°C)
Operating Pressure 30 psi (207 kPa) - 100 psi (689 kPa)
Capacity 240 gallons (900 L) or six months