Performance Data Sheet

Performance Data Sheet
Refrigerator Water Filter Models: EQG-2
Substance Inf. Average
NSF Specified
Challenge
Concentration
Ave. %
Reductio
n
Average Product
Water
Concentration
Max Permissible
Product Water
Concentration
NSF
Reduction
Requirement
s
Test
Report
Chlorine
Taste and Odor
2.1 mg/L 2.0 mg/L ± 10% 97.0% 0.063 mg/L N/A ≥50% J-00295502
Benzene 15 ug/L 15 ug/L ± 10% 96.6% 0.5 ug/L 0.5 ug/L N/A J-00268283
Carbofuran 73 ug/L 73 ug/L ± 10% 98.4% 2 ug/L 40 ug/L N/A J-00268284
Lead (pH 8.5) 140 ug/L 140 ug/L ± 10% 99.6% 0.5 ug/L 10 ug/L N/A J-00268279
Lead (pH 6.5) 140 ug/L 140 ug/L ± 10% 99.6% 0.5 ug/L 10 ug/L N/A J-00268280
Cyst
120,000
oocysts/L
minimum 50000
oocysts/L
99.99% 1 oocysts/L N/A ≥99.95% J-00263594
Endrin 6 ug/L 6 ug/L ± 10% 93.6% 0.3 ug/L 2 ug/L N/A J-00296278
Mercury (pH 8.5) 6 ug/L 6 ug/L ± 10% 92.3% 0.5 ug/L 2 ug/L N/A J-00326152
Mercury (pH 6.5) 6 ug/L 6 ug/L ± 10% 93.8% 0.3 ug/L 2 ug/L N/A J-00268282
1, 2, 4-
Trichlorobenzene
0.21 mg/L 0.21 ± 10% mg/L 97.7% 0.005 mg/L 0.07 mg/L N/A 3321-22004
p-dichlorobenzene 0.225 mg/L 0.225 ± 10% mg/L 98.6% 0.003 mg/L 0.075 mg/L N/A 3321-22005
Tetrachloroethylene 0.015 mg/L 0.015 ± 10% mg/L 0.9935 0.0001 mg/L 0.005 mg/L N/A 22-186-2-Tetrachloroethylene
o-Dichlorobenzene 1.8 mg/L 1.8 ± 10% mg/L 0.9999 0.0002 mg/L 0.6 mg/L N/A 22-186-1
Carbon Tetrachloride 0.015 mg/L 0.015 ± 10% mg/L 0.9664 0.0005 mg/L 0.005 mg/L N/A 22-224-Carbon Tetrachloride
Ethylbenzene 2.1 mg/L 2.1 ± 10% mg/L 0.9959 0.0086 mg/L 0.7 mg/L N/A 22-224-Ethylbenzene
2,4 D 0.21 mg/L 0.21 ± 10% mg/L 0.998 0.00042 mg/L 0.07 mg/L N/A 22-224-2,4 D
Toxaphene 0.015 mg/L 0.015 ± 10% mg/L 0.9787 0.0003 mg/L 0.003 mg/L N/A 22-224-Toxaphene
Lindane 0.002 mg/L 0.002 ± 10% mg/L 0.9527 0.0001 mg/L 0.0002 mg/L N/A 22-224-Lindan
MTBE 0.015 mg/L 0.015 ± 20% mg/L 98,64% 0.0002 mg/L 0.005 mg/L N/A 22-224-MTBE
Atrazine 0.009 mg/L 0.009 ± 10% mg/L 0.989 0.0001 mg/L 0.003 mg/L N/A 22-224-Atrazin
Phenytoin 0.21 ug/L 0.2 ug/L ± 20% 0.952 10 ng/L 30 ng/L N/A J-00268287
Ibuprofen 0.42 ug/L 0.42 ug/L ± 20% 94.4% 22 ng/L 60 ng/L N/A J-00268287
Naproxen 0.13 ug/L 0.14 ug/L ± 20% 96.2% 5 ng/L 20 ng/L N/A J-00268287
Estrone 0.15 ug/L 0.14 ug/L ± 20% 96.6% 5 ng/L 20 ng/L N/A J-00268287
Bisphenol A 2.5 ug/L 2 ug/L ± 20% 99.2% 20 ng/L 300 ng/L N/A J-00268287
Nonyl phenol 1.8 ug/L 1.4 ug/L ± 20% 97.2% 50 ng/L 200 ng/L N/A J-00268287
Trimethoprim 140 ng/L 140 ng/L ± 20% 99% 1.4 ng/L 20 ng/L N/A 22-186-Group 1
Carbamazepine 1400 ng/L 1400 ng/L ± 20% 99% 14 ng/L 200 ng/L N/A 22-186-Group 1
Atenolol 200 ng/L 200 ng/L ± 20% 99% 2 ng/L 30 ng/L N/A 22-186-Group 1
Meprobamate 400 ng/L 400 ng/L ± 20% 99% 4 ng/L 60 ng/L N/A 22-186-Group 1
DEET 1400 ng/L 1400 ng/L ± 20% 0.9691 44 ng/L 200 ng/L N/A 22-186-Group 1
Metolachlor 1400 ng/L 1400 ng/L ± 20% 99% 14 ng/L 200 ng/L N/A 22-186-Group 1
Linuron 140 ng/L 140 ng/L ± 20% 99% 1.4 ng/L 20 ng/L N/A 22-186-Group 1
TCEP 5000 ng/L 5000 ng/L ± 20% 0.9784 108 ng/L 700 ng/L N/A 22-241- Group 2
TCPP 5000 ng/L 5000 ng/L ± 20% 0.9625 188 ng/L 700 ng/L N/A 22-241- Group 2
FILTER SPECIFICATIONS
Flow Rate: 0.5 gpm / 1.9 lpm
Operating Temperature:
33 - 100°F (0.6°C - 38°C)
Operating Pressure: 20 psi (140 kPa) - 100 psi (689 kPa)
Capacity: 300 gallons (1,136 L) or six months
Systems certified for cyst reduction may be used on disinfected waters that may
contain filterable cysts. The system conforms to NSF/ANSI 42, 53, 372, 401, for the
specific performance claims as verified and substantiated by test data. Note: Testing
was performed under standard laboratory conditions, actual performance may vary.
System to be used with municipal or well water sources treated and tested on regular
basis to ensure bacteriological safe quality. Do not use with water that is
microbiologically unsafe or of unknown quality without adequate disinfection before
or after the system.
It is essential that the manufacturer’s recommended installation, maintenance and
filter replacement requirements be carried out for the product to perform as
advertised. Manufactured by Qingdao Ecopure Filter Co.,Ltd Qingdao China
The compounds under NSF/ANSI 401 have been deemed as ‘incidental contaminants /
emerging compounds’.
Limited Warranty: This filter hereunder shall be free from material defects in material
and workmanship for a period of one (1) year from the date of purchase. To reduce the
risk of property damage due to water leakage, this filter MUST be installed in accordance
with the manufacturer’s specifications and installations. This filter unit must be replaced
every 6 months, at the rated capacity, or sooner if reduced water flow occurs. Protect form
freezing. Failure to follow instructions and operating specifications will void your
warranty. Further, manufacturer assumes no responsibility or liability for damages arising
out of misuse of the product.