Safety Information
Page 22 of 63 Report No.: CQASZ20210400194S
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
B.4.7 Continuous operation of components No such components N/A
B.4.8 Class 1 and Class 2 energy sources within limits
during and after single fault conditions
During and after a single fault
condition, a class 1 or class 2
energy sources did not become a
class 3 energy source.
For a class 3 energy source,
during and after a single fault
condition, at least one safeguard
continued to comply with the
relevant safeguard requirements.
P
B.4.9 Battery charging under single fault conditions ... : (See Annex M) N/A
C UV RADIATION N/A
C.1 Protection of materials in equipment from UV
radiation
No UV radiation N/A
C.1.2 Requirements N/A
C.1.3 Test method N/A
C.2 UV light conditioning test N/A
C.2.1 Test apparatus N/A
C.2.2 Mounting of test samples N/A
C.2.3 Carbon-arc light-exposure apparatus N/A
C.2.4 Xenon-arc light exposure apparatus N/A
D TEST GENERATORS N/A
D.1 Impulse test generators N/A
D.2 Antenna interface test generator N/A
D.3 Electronic pulse generator N/A
E TEST CONDITIONS FOR EQUIPMENT CONTAINING AUDIO AMPLIFIERS N/A
E.1 Audio amplifier normal operating conditions N/A
Audio signal voltage (V) ...................................... :
Rated load impedance (Ω) ................................ :
E.2 Audio amplifier abnormal operating conditions N/A
F EQUIPMENT MARKINGS, INSTRUCTIONS, AND INSTRUCTIONAL SAFEGUARDS P
F.1 General requirements P
Instructions – Language .................................... : English
F.2 Letter symbols and graphical symbols P