Safety Information
Page 25 of 63 Report No.: CQASZ20210400194S
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
G.3.1 Thermal cut-offs No thermal cut-offs N/A
G.3.1.1a)
&b)
Thermal cut-outs separately approved according
to IEC 60730 with conditions indicated in a) & b)
N/A
G.3.1.1c) Thermal cut-outs tested as part of the equipment
as indicated in c)
N/A
G.3.1.2 Thermal cut-off connections maintained and
secure
N/A
G.3.2 Thermal links N/A
G.3.2.1a) Thermal links separately tested with IEC 60691 No thermal links N/A
G.3.2.1b) Thermal links tested as part of the equipment N/A
Aging hours (H) .................................................. :
Single Fault Condition ........................................ :
Test Voltage (V) and Insulation Resistance () . :
G.3.3 PTC Thermistors No PTC thermistors N/A
G.3.4 Overcurrent protection devices Approved fuse provided P
G.3.5 Safeguards components not mentioned in G.3.1 to G.3.5 N/A
G.3.5.1 Non-resettable devices suitably rated and
marking provided
N/A
G.3.5.2 Single faults conditions ........................................ : (See appended Table B.4) N/A
G.4 Connectors
P
G.4.1 Spacings P
G.4.2 Mains connector configuration .......................... : P
G.4.3 Plug is shaped that insertion into mains socket-
outlets or appliance coupler is unlikely
N/A
G.5 Wound Components
P
G.5.1 Wire insulation in wound components ................ Approved TIW used in transformer
(See Annex J)
P
G.5.1.2 a) Two wires in contact inside wound component,
angle between 45° and 90°
Separated by the insulation tape P
G.5.1.2 b) Construction subject to routine testing N/A
G.5.2 Endurance test on wound components N/A
G.5.2.1 General test requirements N/A
G.5.2.2 Heat run test N/A
Time (s) ............................................................... :
Temperature (C) ................................................. :
G.5.2.3 Wound Components supplied by mains N/A
G.5.3 Transformers
P