Safety Information
Page 26 of 63 Report No.: CQASZ20210400194S
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
G.5.3.1 Requirements applied (IEC61204-7, IEC61558-
1/-2, and/or IEC62368-1) .................................... :
The isolation transformer meets
the requirements given in G.5.3.2
and G.5.3.3
P
Position ................................................................ : Power Transformer T1
Method of protection .......................................... : Electronic protection
G.5.3.2 Insulation P
Protection from displacement of windings ........... : By bobbin and insulation tape
G.5.3.3 Overload test ...................................................... : (See appended table B.3) P
G.5.3.3.1 Test conditions P
G.5.3.3.2 Winding Temperatures testing in the unit Maximum temperatures of
windings did not exceed the limits
given in Table G.3.
During the test, the transformer did
not emit flames or molten metal.
P
G.5.3.3.3 Winding Temperatures - Alternative test method N/A
G.5.4 Motors
N/A
G.5.4.1 General requirements N/A
Position .............................................................. :
G.5.4.2 Test conditions N/A
G.5.4.3 Running overload test N/A
G.5.4.4 Locked-rotor overload test N/A
Test duration (days) ........................................... :
G.5.4.5 Running overload test for d.c. motors in
secondary circuits
N/A
G.5.4.5.2 Tested in the unit N/A
Electric strength test (V) ...................................... :
G.5.4.5.3 Tested on the Bench - Alternative test method;
test time (h) ........................................................ :
N/A
Electric strength test (V) ...................................... :
G.5.4.6 Locked-rotor overload test for d.c. motors in
secondary circuits
N/A
G.5.4.6.2 Tested in the unit N/A
Maximum Temperature ...................................... : N/A
Electric strength test (V) .................................... : N/A
G.5.4.6.3 Tested on the bench - Alternative test method;
test time (h) ......................................................... :
N/A
Electric strength test (V) ...................................... : N/A
G.5.4.7 Motors with capacitors N/A
G.5.4.8 Three-phase motors N/A