Safety Information
Page 41 of 63 Report No.: CQASZ20210400194S
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Voltage circuit
designation)
Duration (ms) Upk (V) Ipk (mA)
-- -- -- Normal -- -- --
--
Abnormal -- -- --
Single fault –
SC/OC
-- -- --
5.2.2.5 - Repetitive Pulses
No.
Supply
Voltage
Location (e.g.
circuit
designation)
Test conditions
Parameters
ES Class
Off time (ms) Upk (V) Ipk (mA)
-- -- -- Normal -- -- --
--
Abnormal -- -- --
Single fault –
SC/OC
-- -- --
Test Conditions:
Normal –
Abnormal –
Supplementary information: SC=Short Circuit, OC=Short Circuit
5.4.1.4,
6.3.2, 9.0,
B.2.6
TABLE: Temperature measurements
P
Supply voltage (V) .................... : 90V/60Hz 264V/50Hz
Ambient T
min
(C) ...................... :
25.0 25.0
Ambient T
max
(C) ..................... :
25.0 25.0
Tma (C) .................................. :
25.0
Maximum measured temperature T of part/at:
T (C)
Allowed
T
max
(C)
Power cord
30.8 30.5 70
PCB near DB1
91.7 89.7 130
Capacitor C3
92.8 91.5 105
Inductor L1
90.1 88.8 120
Transformation T1 winding
98.4 89.8 110
Transformation T1 core
88.9 87.7 110
Capacitor CY1
86.4 84.5 125
PCB near U2
82.5 79.8 130
Capacitor C6
72.3 69.7 105
Enclosure (internal, plastic, near transformer T1)
58.3 56.4 --