Safety Information
Page 42 of 63 Report No.: CQASZ20210400194S
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Enclosure (External, plastic, near transformer T1)
53.4 50.6 77
Ambient
25.0 25.0
--
Supplementary information: Type C output: 5Vdc, 3.1A.
#: External surfaces touched occasionally for periodes: 1s<t<10s.
Note 1: Tma should be considered as directed by appliable requirement
Note 2: Tma is not included in assessment of Touch Temperatures (Clause 9)
Temperature T of winding:
t
1
(°C)
R
1
()
t
2
(°C)
R
2
() T (C)
Allowed
T
max
(C)
Insulation
class
-- -- -- -- -- -- -- --
-- -- -- -- -- -- -- --
Supplementary information:
5.4.1.10.2 TABLE: Vicat softening temperature of thermoplastics
N/A
Penetration (mm) ................................................................ : --
Object/ Part No./Material Manufacturer/t
rademark
T softening (°C)
-- -- --
-- -- --
supplementary information:
5.4.1.10.3 TABLE: Ball pressure test of thermoplastics
P
Allowed impression diameter (mm) .................................. :
2 mm
Object/Part No./Material Manufacturer/trademark
Test temperature (C)
Impression diameter (mm)
Enclosure -- 125 1.10
Supplementary information:
1) T1 bobbin is phenolic material, no test required.