Page 46 of 63 Report No.: CQASZ20210400194S
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
[3] Specify method used for measurement as described in IEC 60990 sub-clause 4.3
[4] IEC60990, sub-clause 6.2.2.7, Fault 7 not applicable.
[5] (*) IEC60990, sub-clause 6.2.2.2 is not applicable if switch or disconnect device (e.g., appliance coupler)
provided.
6.2.2 Table: Electrical power sources (PS) measurements for classification
P
Source Description Measurement Max Power after 3 s
Max Power after 5
s*
)
PS Classification
AC mains
USB
Output
Power (W) : -- 17.13
PS2
(Normal
condition)
V
A
(V) : -- 5.015
I
A
(A) : -- 3.41
AC mains
USB
Output
Power (W) :
0 --
PS1
(single fault: U2
SC)
V
A
(V) :
0 --
I
A
(A) :
0 --
AC mains
Type C
Output
Power (W) :
-- 16.73
PS2
(Normal
condition)
V
A
(V) :
-- 4.85
I
A
(A) :
-- 3.44
AC mains
Type C
Output
Power (W) :
0 --
PS1
(single fault: U2
SC)
V
A
(V) :
0 --
I
A
(A) :
0 --
Supplementary Information:
(*) Measurement taken only when limits at 3 seconds exceed PS1 limits
6.2.3.1 Table: Determination of Potential Ignition Sources (Arcing PIS) P
Location
Open circuit
voltage
After 3 s
(Vp)
Measured r.m.s
current
(Irms)
Calculated value
(V
p
x I
rms
)
Arcing PIS?
Yes / No
All circuits (exclude the output
terminal)
-- -- -- Yes
Supplementary information:
Note 1: An Arcing PIS requires a minimum of 50 V (peak) a.c. or d.c. An Arcing PIS is established when the
product of the open circuit voltage (V
p
) and normal operating condition rms current (I
rms
) is greater than 15.
Note 2: Assumption: All circuits inside the equipment enclosure are declared as arcing PIS.