Safety Information
Page 52 of 63 Report No.: CQASZ20210400194S
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Annex Q.1 TABLE: Circuits intended for interconnection with building wiring (LPS)
P
Note: Measured UOC (V) with all load circuits disconnected:
Output Circuit Components U
oc
(V) I
sc
(A) S (VA)
Meas. Limit Meas. Limit
USB 5V output Normal 4.997 3.49 8 17.44 100
USB 5V output Single fault: U2
SC
0 0 8 0 100
Type C 5V
output
Normal
4.994 3.45
8 17.23 100
Type C 5V
output
Single fault: U2
SC
0 0 8 0 100
Supplementary Information:
SC=Short circuit, OC=Open circuit
T.2, T.3,
T.4, T.5
TABLE: Steady force test P
Part/Location Material Thickness
(mm)
Force
(N)
Test Duration
(sec)
Observation
Internal
components
-- -- 10
5 *
Top enclosure
(above T1)
Plastic See table 4.1.2 250
5 *
Bottom
enclosure (under
T1)
Plastic See table 4.1.2 250
5 *
Side enclosure
(near T1)
Plastic See table 4.1.2 250
5 *
Supplementary information:
* During and after the application of the test force, clearance and creepage distances were not reduced below their
required values; there was no rupture, leaks or loosening of any connection or part.
T.6, T.9 TABLE: Impact tests P
Part/Location Material Thickness
(mm)
Vertical
distance (mm)
Observation