Safety Information
Page 56 of 63 Report No.: CQASZ20210400194S
IEC 62368-1 with U.S.A. National differences
Clause Requirement + Test Result - Remark Verdict
6.5.1 PS3 wiring outside a fire enclosure complies with
single fault testing in B.4, or be current limited per
one of the permitted methods.
P
Annex F
(F.3.3.8)
Output terminals provided for supply of other
equipment, except mains, supply are marked with a
maximum rating or references to which equipment
it is permitted to be connected.
P
Annex G
(G.7.1)
Permanent connection of equipment to the mains
supply by a power supply cord is not permitted,
except for certain equipment, such as ATMs.
N/A
Annex G
(G.7.3)
Power supply cords are required to have
attachment plugs rated not less than 125 percent of
the rated current of the equipment.
P
Flexible power supply cords are required to be
compatible with Article 400 of the NEC, and Tables
11 and 12 of the CEC.
P
Annex G
(G.7.5)
Minimum cord length is required to be 1.5 m, with
certain constructions such as external power
supplies allowed to consider both input and output
cord lengths into the requirement. Power supply
cords are required to be no longer than 4.5 m in
length if used in ITE Rooms.
P
Annex H.2 Continuous ringing signals under normal operating
conditions up to 16 mA only are permitted if the
equipment is subjected to special installation and
performance restrictions.
N/A
Annex H.4 For circuits with other than ringing signals and with
voltages exceeding 42.4 V
peak
or 60 V d.c., the
maximum acceptable current through a 2000 ohm
resistor (or greater) connected across the voltage
source with other loads disconnected is 7.1 mA
peak or 30 mA d.c. under normal operating
conditions.
N/A
Annex M Battery packs for stationary applications comply
with special component requirements.
N/A
Annex
DVA (1)
Equipment intended for use in spaces used for
environmental air are subjected to special
flammability requirements for heat and visible
smoke release.
N/A
For ITE room applications, automated information
storage systems with combustible media greater
than 0.76 m
3
(27 cu ft) have a provision for
connection of either automatic sprinklers or a
gaseous agent extinguishing system with an
extended discharge.
N/A