Model 2650KL / 2700KL Patient Wheelchair Scales User Instructions P/N UM2650KL / 2700KL Rev 1-031512 1
Model 2650KL / 2700KL Thank you for your purchase of this Health o meter® Professional product. Please read this manual carefully, and keep it for easy reference or training. TABLE OF CONTENTS Caution and Warning.................................................................................................3 Specifications for These Scales ................................................................................4 Certifications / Connectivity / Disposal .............................................
CAUTION AND WARNING To prevent injury and damage to your scale, please follow these instructions very carefully. Assemble and operate the scale per the enclosed user instructions. Operate these scales exclusively with the AC adapter provided by Health o meter. Use of an unspecified adapter will void the warranty, and can pose a serious safety hazard. Prior to using these scales, inspect the AC adapter cord for cracking/fraying, or for broken/bent plug prongs.
CAUTION AND WARNING To prevent patient injury, the patient must be attended throughout the entire weighing event. Exercise caution when rolling patient onto and off of the scale. To prevent injury, excise care when adjusting wheelchair ramps. To prevent injury and damage to your scale, do not drop or mishandle scale, while handling or transporting scale. As this can permanently damage the load cells and may also cause injury to one self.
SPECIFICATIONS FOR THESE SCALES General The Model 2650KL and 2700KL Patient Scales use highly sophisticated microprocessor technology. Each precision scale is designed to provide accurate, reliable, and repeatable weight measurements. In addition, each scale is designed to provide the user with features that make the weighing process simple, fast, and convenient. These scales are set up to use motion-sensing weighing technology in order to determine the actual weight of a moving patient.
CERTIFICATIONS / CONNECTIVITY / DISPOSAL Certification Descriptions Pelstar, LLC has been officially certified as the manufacturer of Health o meter® Professional medical devices. The Pelstar, LLC quality assurance system covers the development, production, sales and service of medical scales and measuring systems. This product is tested to and meets the requirements of: 1. UL60601-1 First Edition: Safety for Medical Electrical Equipment 2. CSA C22.2 No.
2650KL ASSEMBLY INSTRUCTIONS Before Assembly Each 2650KL scale is shipped disassembled in a single carton. Carefully inspect the carton for shipping damage before unpacking. If damage is found, contact your shipper or a Health o meter® Professional representative immediately. Claims must be filed with the shipper as soon as possible after receipt of the package. The following information details what you will find inside the main carton as you unpack the parts for assembly.
2650KL ASSEMBLY INSTRUCTIONS (CONTINUED) Assembling the 2650KL Scale (Refer to Figures 1-3) Caution: It is recommended that the assembly be performed by two persons. 1. Place scale platform on a flat, level, and dry surface, and carefully turn the platform upside down. Caution: Ensure that the wheelchair ramps are held in place when moving the scale ramps can flip open. 2. Thread the (4) feet into the underside of the platform. Each foot should be completely hand tightened into the platform.
2650KL ASSEMBLY INSTRUCTIONS (CONTINUED) Figure 1 Load Cell Port Figure 2 9
2650KL ASSEMBLY INSTRUCTIONS (CONTINUED) Figure 3 10
2700KL ASSEMBLY INSTRUCTIONS Each 2700KL scale is shipped disassembled in a single carton. Carefully inspect the carton for shipping damage before unpacking. If damage is found, contact your shipper or a Health o meter® Professional representative immediately. Claims must be filed with the shipper as soon as possible after receipt of the package. The following information details what you will find inside the main carton as you unpack the parts for assembly.
2700KL ASSEMBLY INSTRUCTIONS (CONTINUED) Assembling the 2700KL Scale (Refer to Figures 4-6) Caution: It is recommended that the assembly be performed by two persons. 1. Place scale platform on a flat, level, and dry surface, and carefully turn the platform upside down. Caution: Ensure that the wheelchair ramps are held in place when moving the scale ramps can flip open. 2. Thread the (4) feet into the underside of the platform. Each foot should be completely hand tightened into the platform.
2700KL ASSEMBLY INSTRUCTIONS (CONTINUED) Figure 4 Load Cell Port Figure 5 13
2700KL ASSEMBLY INSTRUCTIONS (CONTINUED) Figure 6 Figure 7 14
DISPLAY ASSEMBLY WALL MOUNT INSTRUCTIONS Display Assembly Wall Mounting Instructions Caution: When wall mounting the display assembly, ensure that the mounting location is free of electrical lines, gas pipes, and other safety hazards. Ensure that wall is of construction that can support the display assembly. 1. Position the display assembly on the wall, and carefully trace around the display outline. 2. Mark a level horizontal line, 2-¾” (70mm) below the top of the display outline. 3.
SETUP / BATTERIES / TRANSPORT Preparing the 2650KL / 2700KL Scale for Use 1. Remove the protective plastic film covering the display (the film says “FACTORY CALIBRATED”). 2. Place batteries into the battery holder (see Figure 7). 3. Plug the scale’s AC adapter into the power source. 4. Ensure all objects are removed from the scale’s platform. Press the ON/OFF button to turn the scale on. The display will show “Start”, then “0.0LB” or “0.0KG”. 5. Press the UNIT button to select the weight mode (lb or kg).
SETUP / BATTERIES / TRANSPORT (CONTINUED) Preparing a 2650KL / 2700KL Scale for Transport These scales can be easily folded for movement from one room to another. Both scales include mounting pins to secure the display assembly during transport (the pins are located on the right wheelchair ramp). To prepare the scale for transport, follow these steps: 1. Remove the display assembly from the wall by lifting up the assembly off of the mounting screws. 2.
QUICK START / OPERATING INSTRUCTIONS Keypad Figure 10 Function ON/OFF ZERO HOLD/RELEASE ► BMI RECALL TARE/PRETARE UNIT/▲ REWEIGH ENTER Description Turns scale on and off. Zeros the scale prior to a weighing. Holds the weight value of the patient on the display until the button is pressed again to clear the value. Also moves the cursor from left to right on the display for entering height and pretare value. Prompts entry of height data to calculate patient’s Body Mass Index (BMI).
QUICK START / OPERATING INSTRUCTIONS (CONT) Tare Function When using these scales, the weight of an object, such as a wheelchair, can be subtracted from the total weight in order to determine the weight of the patient alone. The Tare Function automatically performs this subtraction. The 2650KL and 2700KL scales allow tare weight to be entered manually by using the keypad, or automatically, as outlined in this section. Automatic (Push Button Tare) 1.
QUICK START / OPERATING INSTRUCTIONS (CONT) 7. Place the patient in the wheelchair and roll the wheelchair on the scale. The scale will automatically deduct the tare weight as entered, from the gross weight of the patient and the wheelchair. 8. The weight of the patient will appear on the scale. 9. With no weight on the scale, the tare value will remain on the display until changed, cleared, or until the scale is turned off. 10. To remove the Tare, press the TARE button again.
QUICK START / OPERATING INSTRUCTIONS (CONT) BMI Function Body Mass Index is another name for Quetelet Index, a formula that is a convenient and reliable indicator of obesity. Note: The scale will not calculate BMI for a patient that is 24 pounds (12 kg) or less. If a height is not entered for the patient within 30 seconds of pressing the BMI button, the scale will return to the normal weighing mode. 1. Make sure there is no object on the weighing platform. 2. Press the ON/OFF button to turn the scale on. 3.
MAINTENANCE Maintenance The following pages provide instructions for maintenance, cleaning, calibrating, and troubleshooting for the 2650KL or 2700KL scale. Maintenance operations other than those described in this manual should be performed by qualified service personnel. Caution: Before first use, or after long periods of non-use, check the scale for proper operation and function. If the scale does not operate correctly, refer to qualified service personnel. 1.
CALIBRATION Calibration These scales have been factory calibrated, and does not require calibration prior to use. For maintenance, the scale can be calibrated. Calibration of your 2650KL or 2700KL scale is performed using kilograms (kg) or pounds (lb), according to the units of measure used upon entering into the calibration path. The following calibration assumes the scale is set to pounds, and 400 lb (the default weight) is employed as the calibration weight.
TROUBLESHOOTING Troubleshooting Before contacting service personnel, refer to the following instructions to check and to correct any failures. Symptom Scale does not turn on Possible Cause Corrective Action 1. Dead Battery 1. Replace batteries 2. Faulty electrical outlet 2. Use a different outlet 3. Bad power supply 3. Replace AC adapter 1. External object interfering with the scale 1. Remove interfering object from the scale 2. The display did not show “0.0” before weighing 2.
WARRANTY Limited Warranty What does the Warranty Cover? Health o meter® Professional scales are warranted from date of purchase against defects of materials or in workmanship for a period of two (2) years. If product fails to function properly, return the product, freight prepaid and properly packed to Pelstar, LLC (see “To Get Warranty Service”, below, for instructions).