Model 500KL Eye Level Digital Beam Scale User Instructions P/N UM500KL Rev 1-040912 1
Model 500KL Thank you for your purchase of this Health o meter® Professional product. Please read this manual carefully, and keep it for easy reference or training. TABLE OF CONTENTS Caution and Warning.................................................................................................3 Specifications for This Scale .....................................................................................5 Certifications / Connectivity / Disposal ....................................................
CAUTION AND WARNING When Operating this scale: To prevent injury and damage to your scale, please follow these instructions very carefully. To prevent injury, as well as scale damage during assembly, exercise caution when assembling the scale column. Assemble and operate the scale per the enclosed user instructions. For accurate weighing, this scale must be placed on a flat, stable surface.
CAUTION AND WARNING When operating this scale with the AC adapter: Operate this scale exclusively with the AC adapter provided by Health o meter. Use of an unspecified adapter will void the warranty, and can pose a serious safety hazard. For use with AC adapter model ADPT30 (International, plug kit) or ADPT31 (Domestic, USA). Prior to using this scale, inspect the AC adapter cord for cracking / fraying, or for broken / bent plug prongs.
SPECIFICATIONS FOR THIS SCALE General The Model 500KL eye level digital beam scale uses highly sophisticated microprocessor technology. Each precision scale is designed to provide accurate, reliable and repeatable weight measurements. In addition, each scale is designed to provide the user with features that make the weighing process simple, fast, and convenient. This scale is set up to use motion-sensing weighing technology in order to determine the actual weight of a moving patient.
CERTIFICATIONS / CONNECTIVITY / DISPOSAL Certification Descriptions Pelstar, LLC has been officially certified as the manufacturer of Health o meter® Professional medical devices. The Pelstar, LLC quality assurance system covers the development, production, sales and service of medical scales and measuring systems. This product is tested to and meets the requirements of: 1. UL60601-1 First Edition: Safety for Medical Electrical Equipment 2. CSA C22.2 No.
500KL ASSEMBLY INSTRUCTIONS Before Assembly Each 500KL eye level digital beam scale is shipped disassembled in one carton. Carefully inspect the carton for shipping damage before unpacking. If damage is found, contact your shipper or a Health o meter® Professional representative immediately at 1-800-815-6615. Claims must be filed with the shipper as soon as possible after receipt of the package. The following information details what you will find inside the main carton as you unpack the parts for assembly.
500KL ASSEMBLY INSTRUCTIONS (CONTINUED) Assembling the 500KL Scale (Refer to Figures 1 - 10) Caution: It is recommended that the assembly be performed by two persons. 1. Carefully remove the scale platform C and columns A and B from the carton. Place the scale platform and columns on a flat, level, and dry surface (see Figure 1). 2. Remove the 4 small screws and washers from the bottom of column B (see Figures 1 & 2). 3. Locate cable connector inside column A (see Figures 1 & 3). 4.
500KL ASSEMBLY INSTRUCTIONS (CONTINUED) Figure 1 Screws and washers Column B Figure 2 9
500KL ASSEMBLY INSTRUCTIONS (CONTINUED) Column A Cable connector Figure 3 RJ jack Scale platform C Figure 4 10
500KL ASSEMBLY INSTRUCTIONS (CONTINUED) Column A Locking tab Notch Column B Figure 5 Screw holes Screw holes Scale platform C Figure 6 11
500KL ASSEMBLY INSTRUCTIONS (CONTINUED) Adaptor Jack Washer Screws Figure 7 Upper Height rod D Locking tab Notch Lower Height rod E Figure 8 12
500KL ASSEMBLY INSTRUCTIONS (CONTINUED) Fully assembled height rod Figure 9 Height rod E Height rod opening G Locking tab F Column A Figure 10 13
500KL ASSEMBLY INSTRUCTIONS (CONTINUED) Final assembly Figure 11 14
SETUP / BATTERIES Preparing the 500KL Scale for Use Replacing / Inserting Batteries 1. Remove the protective plastic film covering the display (the film says “FACTORY CALIBRATED”). 2. Unplug the optional AC adapter, if connected to a power source. 3. With a Phillips head screwdriver remove the screw from the battery compartment cover and remove the battery cover on the back of the display assembly by pressing the locking tab (see Figure 12). 4. Replace or install the batteries with new units.
SETUP / BATTERIES Locking tab Display assembly Battery cover Figure 12 16
QUICK START / OPERATING INSTRUCTIONS Keypad Figure 13 Function ON/OFF ZERO HOLD/RELEASE BMI Description Turns scale on and off. Tares the scale prior to a weighing. Holds the weight value of the patient on the display until the button is pressed again to clear the value. Prompts entry of height data to calculate patient’s Body Mass Index (BMI). LB/KG Toggles between pounds (LB) and kilograms (KG). CLEAR Clears the incorrect height input when in BMI mode. UP▲ Increases height input (0.5 in / 0.
QUICK START / OPERATING INSTRUCTIONS (CONT) Auto-Off Function As an energy saving feature, the scale will automatically turn off after 2 minutes of inactivity. By default this function is enabled. Disable Auto-Off 1. While the scale is turned off, press and hold the HOLD/RELEASE button. 2. While holding the HOLD/RELEASE button, press the ON/OFF button to turn the scale on. 3. START will briefly appear on the display followed by “AOF=0”. 4.
QUICK START / OPERATING INSTRUCTIONS (CONT) Weighing a Patient Note: When this scale is turned on, it will always default to the settings and units last used (LB or KG). 1. Make sure there is no object on the scale platform. 2. Press the ON/OFF button to turn the display assembly on. 3. Wait until the “0.0” LB or “0.0” KG appears on the display. 4. Ask the patient to step on the scale.
QUICK START / OPERATING INSTRUCTIONS (CONT) Zero Function When using this scale, the weight of an object, can be zeroed out allowing additional weight to be added and displayed. The zero function automatically performs this subtraction. Note: Ensure there are no object on the scale platform. Zero (Push Button) 1. With all weight off the scale, press the ON/OFF button to turn on the scale. 2. Wait until the “0.0” LB appears on the display. 3. Set the unit (LB or KG). 3. Place the object on the scale.
MAINTENANCE Maintenance The following pages provide instructions for maintenance, cleaning, calibrating, and troubleshooting for the 500KL scale. Maintenance operations other than those described in this manual should be performed by qualified service personnel. Caution: Before first use, or after long periods of non-use, check the scale for proper operation and function. If the scale does not operate correctly, refer to qualified service personnel. 1.
CALIBRATION Calibration This scale has been factory calibrated, and does not require calibration prior to use. If required, the scale can be calibrated. Calibration of your 500KL scale is performed using kilograms (KG) or pounds (LB), according to the units of measure used upon entering into the calibration path. The following calibration assumes the scale is set to pounds, and 100 (40 kg) / 200 (80 kg) / 300 (120 kg) / 500 (200 kg) lbs is employed as the calibration standards.
TROUBLESHOOTING Troubleshooting Before contacting service personnel, refer to the following instructions to check and to correct any failures. Symptom Scale does not turn on Possible Cause Corrective Action 1. Dead battery 1. Replace batteries 2. Faulty electrical outlet 2. Use a different outlet 3. Bad power supply 3. Replace AC adapter 1. External object interfering with the scale 1. Remove interfering object from the scale 2. The display did not show “0.0” before weighing 2.
WARRANTY Limited Warranty What does the Warranty Cover? Health o meter® Professional scales are warranted from date of purchase against defects of materials or in workmanship for a period of two (2) years. If product fails to function properly, return the product, freight prepaid and properly packed to Pelstar, LLC (see “To Get Warranty Service”, below, for instructions).