R 3100-I ACT WOOD INSERT Advanced Combustion Technology (ACT) OWNER’S MANUAL Installation and Operation Beaverton Oregon USA Tested and Listed by C US OMNI- Test Laboratories, Inc. Model: 830-0381 CAUTION D DI O N SC O AR T D DO NOT DISCARD THIS MANUAL • Important operating and maintenance instructions included. • Read, understand and follow these instructions for safe installation and operation.
3100-I ACT WOOD INSERT R and Welcome to the Quadra-Fire Family! Hearth & Home Technologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality, durability, and performance. This commitment begins with our research of the market, including ‘Voice of the Customer’ contacts, ensuring we make products that will satisfy your needs.
R 3100-I ACT WOOD INSERT TABLE OF CONTENTS SAFETY & OVERVIEW OF APPLIANCE MAINTENANCE Serial Number /Listing Label Location------------------- 2 Dimensions------------------------------------------------------ 4 Minimum Clearances to Combustibles------------------- 5 Installation Recommendations----------------------------- 6 Listings & Safety Notices------------------------------------ 6 Chimney Height & Draft and 2-10-3 Rule--------------- 6 Installation Recommendations----------------------------- 6
3100-I ACT WOOD INSERT R INSERT DIMENSIONS 27-7/16" (697mm) 22-7/16" (570mm) TOP VIEW CL 8-5/8" (219mm) 5-3/8" (137mm) 14-1/8" (359mm) 12-3/16" (310mm) 38-7/8" (987mm) 23-1/8" (587mm) SIDE VIEW 21-1/2" (546mm) 20-3/8" (518mm) 7-7//8" ( 00mm) 26-1/4" (667mm) FRONT VIEW A Page Panel A Size STD 44-5/8” 30-1/2” Large 34-1/2” 50-1/2” B B 250-6381D September 1, 2008
R 3100-I ACT WOOD INSERT CLEARANCES TO COMBUSTIBLES United States and Canada Maximum Mantel Depth - 10" (254mm) Mantel SideWall B A B Fascia or Trim C A Insert F D E C Hearth Extension *Zero Clearance Installations USA Only In Canada a full length 6” (152mm) S635 flue liner required as per ULC S628. NOTE: When installing into a masonry fireplace, the fireplace must be built to UBC Chapter 37 standards. Do not remove brick or mortar from masonry fireplace to accommodate insert.
3100-I ACT WOOD INSERT R LISTINGS CHIMNEY HEIGHT/DRAFT (CONT’D) These installation instructions describe the installation and operation of the Quadra-Fire 3100-I ACT Wood Insert. This insert meets the U.S. Environmental Protection Agency’s 1990 particulate emission standards. The 3100-I ACTis listed by OMNI-Test Laboratories, Inc. to UL Safety Standard 1482, and ULC S628, and (UM) 84-HUD.
R 3100-I ACT WOOD INSERT GENERAL INSTALLATION PROCEDURE • • • • • • • • • • • DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. Install liner, if required, for your chosen installation. Attach metal warning plate to the back of the fireplace with screws or nails. Set appliance on the hearth (See Hearth Requirements page 5 and Support Kit information on page 14. Complete the vent connection required for your installation type.
3100-I ACT WOOD INSERT R CHIMNEY REQUIREMENTS A chimney must be the required height above the roof or other obstruction for safety and for proper draft operation. The requirement is that the chimney must be at least 3 feet (91cm) higher than the highest point where it passes through the roof, and at least 2 feet (61cm) higher than the highest part of the roof or structure that is within10 feet (305cm) of the chimney, measured horizontally. Refer to Figure 8C.
R 3100-I ACT WOOD INSERT INSTALLATION OPTIONS Refer to: Clearances to Combustibles on page 5, Canadian Installation requirements on page 11, Hearth Requirements on page 5 and Zero Clearance Adjustable Support Kit on page 14.
3100-I ACT WOOD INSERT R Factory built zero clearance fireplace (usa installations only) The Quadra-Fire 3100-I ACT Wood Stove Insert is listed to UL 1482 Standard and approved for installation into listed factory built zero clearance fireplaces listed to UL 127 conforming to the following specifications and instructions: Mantel The original factory-built clearance fireplace chimney cap must be re-installed after installing the approved chimney liner meeting type H.T. requirements (2100°F) per UL 1777.
R 3100-I ACT WOOD INSERT INSTALLATION IN CANADA MASONRY and HEAT-CIRCULATING (INSTALLATIONS INTO FACTORY-BUILT FIREPLACES ARE PROHIBITED IN CANADA) Whether installed in a masonry or heat-circulating fireplace, this fireplace insert must be installed with a continuous chimney liner of 6” (152mm) diameter extending from the fireplace insert to the top of the chimney.
3100-I ACT WOOD INSERT R INSTALLATION OF PANEL SET AND TRIM Part No. Description 831-0862 Large, Gold Size 50-1/2” x 34-1/2” Part No. Description Size SP-31S-NL SP-31L-NL Std, Nickel 44-5/8” x 30-1/2” Large, Nickel 50-1/2” x 34-1/2” Kit Includes: (2) Side Panels, left & right; (1) Panel Top & Fastener package; (2) Side Trim, left & right; (1) Trim Top & Fastener package. Tools Needed: Powered Phillips head screw driver. Attaching Panels to the Insert 1.
R 3100-I ACT WOOD INSERT FAN (BLOWER) INSTALLATION INSTRUCTIONS Part No. 831-1101 Black & White Wires Attach to Fan Motor Terminals Speed Control Power Cord Strain Relief Location, Holding Together Power Cord and Fan Motor Wires Screens (Fan Covers) Feed Fan Motor Wires Through Holes Included in Kit: (2) Fan mounts & fan assemblies; (1) Speed Control, Power Cord/wire assembly; (1 set) Fan Connector wires, must be high temperature wire; and (1) Strain relief.
R 3100-I ACT WOOD INSERT ZERO CLEARANCE ADJUSTABLE TRIM SUPPORT, 2” to 10” Part No. 841-0990, size 9” x 45” and Part No. ADJSPT-12, size 12” x 50” Included in Kit: (1) Trim Top, (1) Trim Front, (2) Trim Sides, Double-Sided Tape (already installed) Tools Needed: Phillips Head Screwdriver, Sheet Metal Shears, Measuring Tape, Gloves 1. The 10 screws on each set of scissors will already be loose when shipped. See Figure 14A. EXPLODED VIEW OF SCISSORS 2. Expand scissors to desired height.
3100-I ACT WOOD INSERT R OPERATION WOOD SELECTION AND STORAGE Burn only dry seasoned wood. Dry, well-seasoned wood will not only minimize the chance of creosote formation but will give you the most efficient heat output. Even dry wood contains at least 15% moisture by weight and should be burned hot enough to keep the chimney hot enough to maintain particulate (smoke) burning. Burning unseasoned wood of any variety defeats the stoves’ efficiency.
R 3100-I ACT WOOD INSERT OPERATING TIPS For maximum operating efficiency with the lowest emissions, follow these operating procedures: 1. Regardless of desired heat output, when loading your insert, burn your Quadra-Fire with both air controls wide open for a minimum of 5 to 15 minutes. 2. Regulate burn rate (heat output) by using the Primary Control (located under the ashlip). The Start-Up Air Control (right side) is mainly for initial start-up and reloading. 3.
R 3100-I ACT WOOD INSERT air quality AND your Quadra-Fire Insert In recent years there has been an increasing concern about the quality of our air. Much of the blame for poor air quality has been placed on the burning of wood for home heating. In order to improve this situation we at Quadra-Fire have developed cleaner burning inserts that surpass the stringent requirements for emissions established by our governing agencies.
R 3100-I ACT WOOD INSERT MAINTENANCE CARE AND CLEANING OF PLATED SURFACES IMPORTANT: You must clean all the fingerprints and oils from the plated surfaces before firing the insert for the first time. Use warm soapy water and a soft rag, glass cleaner and a paper towel, or vinegar and a paper towel to remove the oils. DO NOT use abrasive cleaners! If not cleaned properly prior to lighting the first fire, the oils can cause permanent stains.
R 3100-I ACT WOOD INSERT brick replacement instructions The firebox of your Quadra-Fire 3100-I ACT Insert is lined with high quality firebrick which has exceptional insulating properties. There is no need for a grate, simply build a fire on the firebox of your insert. Figure 19A 3 3 5 4 1 4 1 Remove all old brick and ash from unit. Remove new brick set from box and lay out to diagram as shown in Figure 19A. Lay bottom bricks in unit. Install rear bricks on the top of the bottom bricks.
3100-I ACT WOOD INSERT R EXPLODED VIEW 10 9 11 8 4 7 2 3 6 5 1 Item Page 20 Item Description 1 Trim Ring, Louver Description 7 Screen, Left/Right (interchangeable) 2 Manifold Tubes, Back (3) 8 Speed Control 3 Manifold Tube, Front (1) 9 Baffle, Fiberboard 4 Spring Handle, 1/4” (2) 10 Blanket, Ceramic 5 Blower Assembly 11 Brick, Set 6 Louver Assembly 250-6381D September 1, 2008
R 3100-I ACT WOOD INSERT Service parts Item # Part Description Alphabetical Order SKU 9 Baffle, Fiberboard 831-1800 10 Blanket, Ceramic, 1 inch thick 832-3401 Blower Assembly, with Wire Harness 831-1101 Blower Cord with Speed Control & Wire Harness 832-1400 Blower Assembly 831-1101 Blower Replacement (1) 832-3190 Brick Set 831-1830 Brick with Hole SRV436-0380 Brick, Single, Uncut 832-0550 Brick, Uncut, Set of 6 832-3040 5 11 Component Pack (Includes Owner’s Manual, Touch-Up Paint
3100-I ACT WOOD INSERT R Item # Part Description Alphabetical Order SKU 1 Trim Ring for Louver, Gold 430-2691 1 Trim Ring for Louver, Nickel 430-5430 Upgrade Kit to Nickel, Door UK-DRNL Washer, Spacing SAE 3/8 for Door Handle 220-0010 14 Item 21 20 22 19 18 17 16 12 13 14 15 Description Part No.
3100-I ACT WOOD INSERT R Service And Maintenance Log Date of Service September 1, 2008 Performed By Description of Service 250-638D Page 23
3100-I ACT WOOD INSERT R Service And Maintenance Log (Cont’d) Date of Service Page 24 Performed By Description of Service 250-6381D September 1, 2008
3100-I ACT WOOD INSERT R Homeowner’s Notes September 1, 2008 250-638D Page 25
3100-I ACT WOOD INSERT R Warranty Policy Hearth & Home Technologies LIMITED WARRANTY Hearth & Home Technologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood, pellet and electric appliances purchased from an authorized HHT dealer and installed in the United States of America or Canada. Warranty starts with date of purchase by the original owner (End User) except as noted for replacement parts.
R 3100-I ACT WOOD INSERT Hearth & Home Technologies LIMITED WARRANTY (Cont’d) HHT’s obligation under this warranty does not extend to damages resulting from: (1) installation, operation or maintenance of the appliance not in accordance with the installation instructions; operating instructions and the listing agent identification label furnished with the appliance; (2) installation which does not comply with local building codes; (3) shipping, improper handling, improper operation, abuse, misuse, accid
R CONTACT INFORMATION: Hearth & Home Technologies 1445 North Highway Colville, WA 99114 Division of HNI INDUSTRIES Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer, log onto www.quadrafire.com CAUTION • Do NOT discard this manual. • Important operating and maintenance instructions included. • Read, understand and follow these instrucitons for safe installation and operation.