SAFETY INFORMATION
ELECTRICAL CONNECTION:
A 15-amp, 120-volt, 60 Hz circuit with a properly grounded
outlet is required. Preferably, the fireplace will be on
a dedicated circuit as other appliances on the same
circuit may cause the circuit breaker to trip or the fuse
to blow when the heater is in operation. The unit comes
standard with 6-ft. three-wire cord, exiting from the rear
of the fireplace. DO NOT exceed the current rating of
the current tap. ALWAYS plug this unit dire
ctly into a wall
outlet/receptacle. NEVER use with an extension cord or
relocatable power tap (outlet/power strip).
shown below. See illustration for grounding instruction. An
adapter as shown at C is available for connecting three-
blade grounding type plugs to two-slot receptacles. The
green grounding lug extending from the adapter must
be connected to a permanent ground such as a properly
grounded outlet box. The adapter should not be used if a
three-slot grounded receptacle is available.
Grounding Pin
Grounding Pin
Grounding Means
Adapter
A
C
B
D
Metal Screw
Cover of
Grounding Box
ELECTRICAL SPECIFICATIONS
Voltage:
Amps:
Watts:
120 VAC, 60 Hz
12.5 Amps
1500 Watts
13
FIREBOX OPERATIONS
OPERATING INSTRUCTIONS
TO ACCESS CONTROL PANEL
Control panel can be accessed at upper right corner of insert.
POWER
Press this switch for main power and flame effect. The indicator light will turn on.
HEATER
The HEATER switch turns the heater ON and OFF.