6777-NW STOP! #ALL5S&IRST $/./42%452.4/34/2% For immediate help with assembly or product information call our toll free number: 1-800-577-9663 or email: CUSTOMERSERVICE BACKYARDPRODUCTSLLC COM Our staff is ready to provide assistance April through October M-F 8:00 AM to 6:00 PM EST Saturday 8:30 AM to 4:30 PM EST November through March M - F 8:00 AM to 5:00 PM EST 53%4()3-!.5!, &/29/52%84%.
(This page intentionally left blank.
16777-NW 06/12/2015 A Backyard Products Company s BUILDING RESTRICTIONS AND APPROVALS Be sure to check with local building department and homeowners association for specific restrictions and/ or requirements before building. s ENGINEERED DRAWINGS Contact our Customer Service Team if engineered drawings are needed to pull local permits. s SURFACE PREPARATION To ensure proper assembly you must build your shed on a level surface. Recommended methods and materials to level your shed are listed on page 12.
//,3 Required ❑ Phillips Screwdriver Optional ❑ Tool Belt/ Nail Pouch ❑ Utility Knife ❑ Shingle Blades ❑ Drill / Driver ❑ 1/8" Drill Bit ❑ 3/8" Drill Bit ❑ #2 Philips Drive Bit ❑ Tin Snips (for drip edge) ❑ Caulk Gun ❑ Hammer ❑ Chalk Line ❑ Paint Tools ❑ Nail Gun ❑ Level ❑ Safety Glasses ❑ Pencil ❑ Ladder ❑ Tape Measure ❑ Square • gun nails ❑ WoodGlue ❑ Gloves ❑ Sawsall or Safety! Always use approved safety glasses during assembly. (%,0&5,2%-).
!$$)4)/.!,-!4%2)!,3 #/-0,%4).'9/523(%$ You will need these additional materials: 12x12' 12x16'12x20' 12x24' 3-TAB SHINGLES (Bundles) ...... ALL SIZES PAINT FOR TRIM .................1 Quart 8 11 14 15 Use 100% acrylic latex exterior paint. 2½ 3 3 4 WOOD GLUE ........... Exterior Rated 2 3 4 5 PAINT FOR SIDING (Gallons) .... Use 100% acrylic latex exterior paint. (2) coats recommended. 1" GALVANIZED ROOFING NAILS (lbs). For shingles. .............. CAULK ................................
0!243)$%.4)&)#!4)/.!.$3):%3 WOOD SIZE CONVERSION CHART Double letter part identification is stamped on some parts. Nominal Board Size RS RS Actual Size 2" x 4"..............1-1/2" x 3-1/2" (3,8 x 8,9 cm) 1" x 4".................3/4" x 3-1/2" (1,9 x 8,9 cm) RS 2" x 3"..............1-1/2" x 2-1/2" (3,8 x 6,3 cm) 1" x 3".................3/4" x 2-1/2" (3,8 x 6,3 cm) • Check these locations for part stamp.
!,,0!.%, $//230!243,)34 x9 x2 x1 x1 LEFT DOOR RIGHT DOOR x1 3/8 x 23-7/8 x 84" (1 x 60,6 x 213,4 cm) 3/8 x 48 x 84" (1 x 121,9 x 213,4 cm) 3/8 x 48 x 84" (1 x 121,9 x 213,4 cm) x1 3/8 x 48 x 84" (1 x 121,9 x 213,4 cm) NOTE: Panel parts are not stamped with part identification. '!",%0!.%,3 x2 x1 3/8 x 43-3/8 x 48" (1 x 110,2 x 121,9 cm) x1 3/8 x 50-7/8 x 48" (1 x 129,2 x 121,9 cm) x2 3/8 x 50-7/8 x 48" (1 x 129,2 x 121,9 cm) 3/8 x 43-3/8 x 48" (1 x 110,2 x 121,9 cm) 2//&0!.
/THER(!2$7!2% x4 5-1/2" (14 cm) Hexbolt, 2 washers and locknut 16-3/4 x 21-3/4" (42,5 x 55,2 cm) x1 x4 x12 3/4" (1,9 cm) x2 x12 1/2" (1,3 cm) x2 x1 x12 x1 16" x 8" ( 40,6 x 20,3 cm) 1-1/2" (3,8 cm) x2 64" Metal Threshold x8 3/4" (1,9 cm) 1" (2,5 cm) .!),"/8%3 12x12' 12x16' 12x20' 12x24' x4 BOXES x6 BOXES x7 BOXES x8 BOXES x6 BOXES x8 BOXES x10 BOXES x12 BOXES 3" (7,6 cm) 2" (5,1 cm) &!34%.
0!243)$%.4)&)#!4)/.!.$3):%3 NOTE: For 12 x 12' Extender, take inventory for 12' x 8' + 12' x 4' kits. WOOD SIZE CONVERSION CHART Part identification is stamped on some parts. Nominal Board Size Actual Size 2" x 4"..............1-1/2" x 3-1/2" (3,8 x 8,9 cm) 1" x 4".................3/4" x 3-1/2" (1,9 x 8,9 cm) RS RS 2" x 3"..............1-1/2" x 2-1/2" (3,8 x 6,3 cm) 1" x 3".................3/4" x 2-1/2" (3,8 x 6,3 cm) • Check these locations for part stamp. 12x4' #,!33)#%34!4% fX f%84%.
0!243)$%.4)&)#!4)/.!.$3):%3 WOOD SIZE CONVERSION CHART Part identification is stamped on some parts. Nominal Board Size Actual Size 2" x 4"..............1-1/2" x 3-1/2" (3,8 x 8,9 cm) 1" x 4".................3/4" x 3-1/2" (1,9 x 8,9 cm) RS RS 2" x 3"..............1-1/2" x 2-1/2" (3,8 x 6,3 cm) 1" x 3".................3/4" x 2-1/2" (3,8 x 6,3 cm) • Check these locations for part stamp. 12x8' #,!33)#%34!4% fX f%84%.$%2+)40!243,)34 RAF TERS WALL INVENTORY YOUR PARTS before you begin.
).3425#4)/.-!.5!,,!9/54 CLASSIC ESTATE 12 x 12' CLASSIC ESTATE 12 x 16' CLASSIC ESTATE 12 x 20' If tab is not displayed, skip to next page including 12' x 16' tab Look for this tab throughout instructions. If tab is not displayed, skip to next page including 12' x 20' tab Look for this tab throughout instructions. If tab is not displayed, skip to next page including 12' x 24' tab )&!,,4!"3!2%$)30,!9%$ &/,,/7!,,).3425#4)/.
#/.#2%4%&/5.$!4)/. (EØXNTØBGNNRDØSNØHMRS@KKØXNTQØJHSØNMØ@ØBNMBQDSDØRK@AØQDEDQØSNØSGDØCH@FQ@LØADKNV SS@BGØSGDØRHKKØOK@SDRØNMØSGDØENTMC@SNMØ@RØRGNVM Ø@MCØBNMSHMTDØNMØSNØO@FDØ Treated Sill Plate Caulk between sill plate and concrete. D D C 3-1/2" (8,9 cm) B A 4" (10,2 cm) Sill plates MUST be treated lumber.
/04)/.!,7//$&2!-%&,//2,%6%,).'/04)/.3 3GDQDØ@QDØLTKSHOKDØV@XRØSNØKDUDKØXNTQØÛNNQØEQ@LD Ø.TQØQDBNLLDMCDCØKDUDKHMFØLDSGNCØHRØRGNVMØADKNV Ø ,EVELINGMATERIALSARENOTINCLUDEDINTHISKIT 02%&%22%$-%4(/$ X 42%!4%$25..%23 4YPICALFOR fX f+IT Runners are generally 12" (30,5 cm) from ends of floor frame and under seams. Measurements to centers of 4x4's. 12" (30,5 cm) DOOR • 3" Screws angled into 4x4. • (2) at each point frame and 4x4 touch.
,%6%,).' 315!2).'! X f&,//2&2!-% .OT)NCLUDED • FOR 12' x 16', SKIP TO PAGE 13 • FOR 12' x 20', SKIP TO PAGE 14 • FOR 12' x 24', SKIP TO PAGE 15 ,%6%,!.$315!2%&,//2&2!-% CLASSIC ESTATE 12 x 12' !DENQDØ@SS@BGHMFØÛØNNQØCDBJHMF ØHSØHRØHLONQS@MSØSNØKDUDKØ@MCØRPT@QDØSGDØÛØNNQØEQ@LD ØKDUDKØ@MCØRPT@QDØÛØNNQØEQ@LDØHRØQDPTHQDCØSNØBNQQDBSKXØBNMRSQTBSØXNTQØRGDC BEGIN 1 See page 11 for the preferred floor leveling method. 2 Use level and check the frame is level before applying floor panels.
,%6%,).' 315!2).'! X f&,//2&2!-% .OT)NCLUDED • FOR 12' x 20', SKIP TO PAGE 14 • FOR 12' x 24', SKIP TO PAGE 15 ,%6%,!.$315!2%&,//2&2!-% !DENQDØ@SS@BGHMFØÛØNNQØCDBJHMF ØHSØHRØHLONQS@MSØSNØKDUDKØ@MCØRPT@QDØSGDØÛØNNQØEQ@LD ØKDUDKØ@MCØRPT@QDØÛØNNQØEQ@LDØHRØQDPTHQDCØSNØBNQQDBSKXØBNMRSQTBSØXNTQØRGDC BEGIN 1 See page 11 for the preferred floor leveling method. 2 Use level and check the frame is level before applying floor panels.
,%6%,).' 315!2).'! X f&,//2&2!-% .OT)NCLUDED • FOR 12' x 24', SKIP TO PAGE 15 ,%6%,!.$315!2%&,//2&2!-% !DENQDØ@SS@BGHMFØÛØNNQØCDBJHMF ØHSØHRØHLONQS@MSØSNØKDUDKØ@MCØRPT@QDØSGDØÛØNNQØEQ@LD ØKDUDKØ@MCØRPT@QDØÛØNNQØEQ@LDØHRØQDPTHQDCØSNØBNQQDBSKXØBNMRSQTBSØXNTQØRGDC BEGIN 1 See page 11 for the preferred floor leveling method. 2 Use level and check the frame is level before applying floor panels. 3 Check for frame squareness by measuring diagonally across corners.
,%6%,).' 315!2).'! X f&,//2&2!-% .OT)NCLUDED ,%6%,!.$315!2%&,//2&2!-% !DENQDØ@SS@BGHMFØÛØNNQØCDBJHMF ØHSØHRØHLONQS@MSØSNØKDUDKØ@MCØRPT@QDØSGDØÛØNNQØEQ@LD ØKDUDKØ@MCØRPT@QDØÛØNNQØEQ@LDØHRØQDPTHQDCØSNØBNQQDBSKXØBNMRSQTBSØXNTQØRGDC BEGIN 1 See page 11 for the preferred floor leveling method. 2 Use level and check the frame is level before applying floor panels. 3 Check for frame squareness by measuring diagonally across corners. If the measurements are the same, the frame is square.
)-0/24!.4 IMP O R TA N T ! NOTE: CLASSIC ESTATE 12' x 12' shown standard throughout manual CLASSIC ESTATE 12 x 12' Check the floor frame is level after installing floor panels. Re-level if needed. CLASSIC ESTATE 12 x 16' R DOO • The floor should used as a stable work surface for wall construction. • Organize your assembly procedure during the build process to avoid over-handling of the walls.
"!#+7!,,&2!-% PARTS REQUIRED: x2 x32 SP 3" (7,6 cm) 2 x 4 x 48" (5,1 x 10,2 x 121,9 cm) x7 AI 2 x 4 x 78-1/2" (5,1 x 10,2 x 199,4 cm) x2 TP 2 x 4 x 96" (5,1 x 10,2 x 243,8 cm) BEGIN Orient parts on edge on floor as shown. 2 Nail using two 3" nails at each connection.
"!#+7!,,0!.%,3 PARTS REQUIRED: x48 GAA 3/8 x 48 x 84" (1 x 121,9 x 213,4 cm ) x1 3/4" GAUGE BLOCK 2" (5,1 cm) UU 2 x 4 x 9" TEMP. SPACER CLASSIC ESTATE 12 x 16' CLASSIC ESTATE 12 x 12' Ensure your wall frame is square by installing one panel and squaring frame. BEGIN 1 Place LEFT panel onto wall frame with primed side up as shown. Locate the panel 1-1/2" above the top plate. Use UU as a gauge block for the 1-1/2" top overhang measurement.
"!#+7!,,0!.%,3 PARTS REQUIRED: x96 3/8 x 48 x 84" (1 x 121,9 x 213,4 cm ) x2 2" (5,1 cm) UU 2 x 4 x 9" TEMP. SPACER Place MIDDLE panel on frame as shown with primed side facing up flush with first panel. Nail using 2" nails 6" apart on edges and 12" apart inside panel. 5 Repeat STEP 4 to secure RIGHT panel. Do not nail in groove. FINISH 6 CLASSIC ESTATE 12 x 12' 4 You have finished building your back wall. For squareness maintain 1-1/2" measurement along panel edge.
fX f3)$%7!,,&2!-%3 PARTS REQUIRED: x4 x48 3" (7,6 cm) STL 2 x 4 x 44-1/2" (5,1 x 10,2 x 113 cm) x4 TJ 2 x 4 x 92-1/2" (5,1 x 10,2 x 235 cm) x10 AI 2 x 4 x 78-1/2" (5,1 x 10,2 x 199,4 cm) CLASSIC ESTATE 12 x 12' IMPORTANT! You will build two walls the same. • FOR 12' x 16', SKIP TO PAGE 23 • FOR 12' x 20', SKIP TO PAGE 26 • FOR 12' x 24', SKIP TO PAGE 29 BEGIN 1 Orient parts on edge on floor. Measure and mark from end of boards. 2 Use two 3" nails at each connection (Fig.
fX f3)$%7!,,0!.%,3 PARTS REQUIRED: x40 GAA 3/8 x 48 x 84" (1 x 121,9 x 213,4 cm ) x1 3/4" GAUGE BLOCK 2" (5,1 cm) UU 2 x 4 x 9" TEMP. SPACER Ensure your wall frame is square by installing one panel and squaring frame. 1 CLASSIC ESTATE 12 x 12' BEGIN Place a 48 x 84" panel onto wall frame with primed side up as shown. Locate the panel 1-1/2" above the top plate. Use UU as a gauge block for the 1-1/2" top overhang measurement.
fX f3)$%7!,,0!.%,3 PARTS REQUIRED: 2" (5,1 cm) UU 3/8 x 48 x 84" (1 x 121,9 x 213,4 cm ) x2 CLASSIC ESTATE 12 x 12' x80 2 x 4 x 9" TEMP. SPACER 4 Place a 48 x 84" panel on frame as shown with primed side facing up flush with first panel. Nail using 2" nails 6" apart on edges and 12" apart inside panel. 5 Place next 48 x 84" panel on frame as shown with primed side facing up flush with second panel. Nail using 2" nails 6" apart on edges and 12" apart inside panel.
fX f3)$%7!,,&2!-%3 PARTS REQUIRED: x14 x64 3" (7,6 cm) AI 2 x 4 x 78-1/2" (5,1 x 10,2 x 199,4 cm) TJ x8 2 x 4 x 92-1/2" (5,1 x 10,2 x 235 cm) IMPORTANT! You will build two walls the same. • FOR 12' x 20', SKIP TO PAGE 26 • FOR 12' x 24', SKIP TO PAGE 29 BEGIN 1 Orient parts on edge on floor. Measure and mark from end of boards. 2 Use two 3" nails at each connection (Fig. A) and four 3" nails at seams (Fig. B). HINT: FINISH 3 Repeat process to make second wall frame.
fX f3)$%7!,,0!.%,3 PARTS REQUIRED: x40 3/8 x 48 x 84" (1 x 121,9 x 213,4 cm ) x1 GAA 2" (5,1 cm) UU 3/4" GAUGE BLOCK 2 x 4 x 9" TEMP. SPACER Ensure your wall frame is square by installing one panel and squaring frame. BEGIN 1 Place a 48 x 84" panel onto wall frame with primed side up as shown. Locate the panel 1-1/2" above the top plate. Use UU as a gauge block for the 1-1/2" top overhang measurement. Use GAA as a gauge block to mark the 3/4" side measurement on the wall stud.
fX f3)$%7!,,0!.%,3 PARTS REQUIRED: x130 2" (5,1 cm) 3/8 x 48 x 84" (1 x 121,9 x 213,4 cm ) x3 UU 2 x 4 x 9" TEMP. SPACER 4 Place 48 x 84" panel on frame as shown with primed side facing up flush with first panel. Nail using 2" nails 6" apart on edges and 12" apart inside panel. 5 Repeat STEP 4 for remaining panels. 6 Carefully flip your sidewall over. Repeat STEPS 1-5 to assemble your second side wall. Do not nail in groove. FINISH 7 You have finished building both of your side walls.
fX f3)$%7!,,&2!-%3 PARTS REQUIRED: x4 x88 3" (7,6 cm) TJ 2 x 4 x 92-1/2" (5,1 x 10,2 x 235 cm) x4 TP 2 x 4 x 96" (5,1 x 10,2 x 243,9 cm) x4 x18 STL 2 x 4 x 44-1/2" (5,1 x 10,2 x 113 cm) AI 2 x 4 x 78-1/2" (5,1 x 10,2 x 199,4 cm) IMPORTANT! You will build two walls the same. • FOR 12' x 24', SKIP TO PAGE 29 BEGIN 1 Orient parts on edge on floor. Measure and mark from end of boards. 2 Use two 3" nails at each connection (Fig. A) and four 3" nails at seams (Fig. B).
fX f3)$%7!,,0!.%,3 PARTS REQUIRED: x1 x40 3/8 x 48 x 84" (1 x 121,9 x 213,4 cm ) GAA 2" (5,1 cm) UU 3/4" GAUGE BLOCK 2 x 4 x 9" TEMP. SPACER Ensure your wall frame is square by installing one panel and squaring frame. BEGIN 1 Place a 48 x 84" panel onto wall frame with primed side up as shown. Locate the panel 1-1/2" above the top plate. Use UU as a gauge block for the 1-1/2" top overhang measurement. Use GAA as a gauge block to mark the 3/4" side measurement on the wall stud.
fX f3)$%7!,,0!.%,3 PARTS REQUIRED: x180 2" (5,1 cm) 3/8 x 48 x 84" (1 x 121,9 x 213,4 cm ) x4 UU 2 x 4 x 9" TEMP. SPACER 4 Place 48 x 84" panel on frame as shown with primed side facing up flush with first panel. Nail using 2" nails 6" apart on edges and 12" apart inside panel. 5 Repeat STEP 4 for remaining panels. 6 Carefully flip your sidewall over. Repeat STEPS 1-5 to assemble your second side wall. Do not nail in groove. FINISH 7 You have finished building both of your side walls.
fX f3)$%7!,,&2!-%3 PARTS REQUIRED: x104 3" (7,6 cm) TP x4 2 x 4 x 96" (5,1 x 10,2 x 243,9 cm) TJ x8 2 x 4 x 92-1/2" (5,1 x 10,2 x 235 cm) x22 AI 2 x 4 x 78-1/2" (5,1 x 10,2 x 199,4 cm) IMPORTANT! You will build two walls the same. BEGIN 1 Orient parts on edge on floor. Measure and mark from end of boards. 2 Use two 3" nails at each connection (Fig. A) and four 3" nails (Fig. B) at seams. FINISH 3 HINT: Repeat process to make second wall frame. Proceed to attach wall panels.
fX f3)$%7!,,0!.%,3 PARTS REQUIRED: x40 3/8 x 48 x 84" (1 x 121,9 x 213,4 cm ) x1 GAA 2" (5,1 cm) UU 3/4" GAUGE BLOCK 2 x 4 x 9" TEMP. SPACER Ensure your wall frame is square by installing one panel and squaring frame. BEGIN 1 Place a 48 x 84" panel onto wall frame with primed side up as shown. Locate the panel 1-1/2" above the top plate. Use UU as a gauge block for the 1-1/2" top overhang measurement. Use GAA as a gauge block to mark the 3/4" side measurement on the wall stud.
fX f3)$%7!,,0!.%,3 PARTS REQUIRED: x230 2" (5,1 cm) 3/8 x 48 x 84" (1 x 121,9 x 213,4 cm ) x5 UU 2 x 4 x 9" TEMP. SPACER 4 Place 48 x 84" panel on frame as shown with primed side facing up flush with first panel. Nail using 2" nails 6" apart on edges and 12" apart inside panel. 5 Repeat STEP 4 for remaining panels. 6 Carefully flip your sidewall over. Repeat STEPS 1-5 to assemble your second side wall. Do not nail in groove. FINISH 7 You have finished building both of your side walls.
&2/.47!,,&2!-% $OOR,ADDER PARTS REQUIRED: x5 x10 3" (7,6 cm) UU 2 x 4 x 9" (5,1 x 10,2 x 22,9 cm) x1 AM 2 x 4 x 67" (5,1 x 10,2 x 170,2 cm) CLASSIC ESTATE 12 x 12' BEGIN 1 Orient parts on edge on floor as shown. 2 Nail using two 3" nails at each connection. FINISH 3 Proceed to assembling front wall frame.
&2/.47!,,&2!-% PARTS REQUIRED: x2 x1 SKA 2 x 4 x 40" (5,1 x 10,2 x 101,6 cm) x6 x24 SP 3" (7,6 cm) 2 x 4 x 48" (5,1 x 10,2 x 121,9 cm) AI 2 x 4 x 78-1/2" (5,1 x 10,2 x 199,4 cm) x1 TP 2 x 4 x 96" (5,1 x 10,2 x 244,9 cm) BEGIN Orient parts on edge on floor around door header as shown. 2 Nail using two 3" nails at each connection and four 3" nails at seam. CLASSIC ESTATE 12 x 12' 1 HINT: DIMENSIONS ARE TO CENTER OF STUDS.
&2/.47!,,&2!-% PARTS REQUIRED: 3" (7,6 cm) Secure door ladder to frame with 3" nails as shown. CLASSIC ESTATE 12 x 12' 3 x28 67" (170,2 cm) HINT: CLASSIC ESTATE 12 x 16' 33-1/2" (85,1 cm) 33-1/2" (85,1 cm) 9-1/2" (24,1 cm) 9-1/2" (24,1 cm) 9" (22,9 cm) (4) 3" (7,6 cm) Nails CLASSIC ESTATE 12 x 20' (2) 3" (7,6 cm) Nails CLASSIC ESTATE 12 x 24' MAINTAIN DIMENSION BETWEEN STUDS.
&2/.47!,,&2!-% PARTS REQUIRED: x2 x24 3" (7,6 cm) UM 2 x 4 x 68" (5,1 x 10,2 x 172,7 cm) 4 Orient parts on edge on floor as shown. 5 Secure using 3" nails as shown. 6 You have finished building your front wall frame. HINT: Flush UM MAINTAIN DIMENSION BETWEEN STUDS.
PARTS REQUIRED: x50 GAA x1 CLASSIC ESTATE 12 x 12' 3/8 x 48 x 84" (1 x 121,9 x 213,4 cm) 3/4" GAUGE BLOCK UU 2 x 4 x 9" TEMP. SPACER BEGIN 1 Place the LEFT panel onto wall frame as shown with primed side up. 2 Use GAA as a gauge block to mark the 3/4" measurement on the wall stud. Locate the panel 1-1/2" from the top plate, using UU as a gauge block. 3 Nail panels to frame with two 2" nails 6" apart on edges. FINISH CLASSIC ESTATE 12 x 16' 2" (5,1 cm) 4 Do not nail in groove.
PARTS REQUIRED: x50 GAA x1 3/8 x 48 x 84" (1 x 121,9 x 213,4 cm) 2" (5,1 cm) UU 3/4" GAUGE BLOCK 2 x 4 x 9" TEMP. SPACER CLASSIC ESTATE 12 x 12' BEGIN 1 Place the RIGHT panel onto wall frame as shown with primed side up. 2 Use GAA as a gauge block to mark the 3/4" measurement on the wall stud. Locate the panel 1-1/2" from the top plate using UU as a gauge block. 3 Nail panels to frame with two 2" nails 6" apart on edges. FINISH 4 Proceed to attaching your wing panels.
PARTS REQUIRED: x1 x2 TP 3" (7,6 cm) x72 Temporary Support 2 x 4 x 96" (5,1 x 10,2 x 243,8 cm) 2" (5,1 cm) x2 CLASSIC ESTATE 12 x 12' 3/8 x 23-7/8 x 84" (1 x 60,7 x 213,4 cm) BEGIN 1 Place wing wall panels onto frame with top of panels ” ush to previously installed panels. 2 Nail left and right wing wall ”ush to panel already attached using 2" nails 6" apart. 3 Attach tempoary support TP using two 3" screws as shown.
"!#+7!,,).34!,,!4)/. PARTS REQUIRED: x12 x2 3" (7,6 cm) 3" (7,6 cm) x27 2" (5,1 cm) BEGIN 1 Center back wall assembly on the 144" (363,8 cm) floor dimension. CLASSIC ESTATE 12 x 12' Ensure 1-1/2" measurement is on top 2 Use OO as a temporary brace. Secure with two 3" screws. 3 First, nail lower edge of panel to floor frame using 2" nails 6" apart. Angle nail to hit floor frame (Fig. A). 4 Nail back wall bottom plate to floor using twelve 3" nails.
3)$%7!,,3).34!,,!4)/. 12x12' 12x16' 12x20' 12x24' PARTS REQUIRED: x2 3" (7,6 cm) x20 x28 x36 x44 x55 x63 x71 x79 3" (7,6 cm) 2" (5,1 cm) CLASSIC ESTATE 12 x 12' BEGIN Stand right sidewall on floor. It is important to secure the sidewall in the following order. 1 Center sidewall on floor front to back. Nail the lower sidewall corner to the backwall with one 2" nail (Fig. A). 2" (5,1 cm) Nail DOOR CLASSIC ESTATE 12 x 16' Fig.
&2/.47!,,).34!,,!4)/. PARTS REQUIRED: x10 x4 3" (7,6 cm) 3" (7,6 cm) x26 2" (5,1 cm) BEGIN Stand front wall on floor. It is important to secure the front wall in the following order. CLASSIC ESTATE 12 x 12' 1 Center front wall on floor side-to-side. Nail the front wall flush to the floor using 2" nails 6" apart. Angle nails to hit floor frame (Fig. A). 64" (162,6 cm) Nail the lower side wall to the front wall corner with one 2" nail (Fig. B). TP CLASSIC ESTATE 12 x 16' Fig.
fX f7!,,$/5",%23).34!,,!4)/. PARTS REQUIRED: x2 x64 x2 SP 2 x 4 x 48" (5,1 x 10,2 x 121,9 cm) x2 x2 3" (7,6 cm) STL 2 x 4 x 44-1/2" (5,1 x 10,2 x 113 cm) x16 3" (7,6 cm) TJ 2 x 4 x 92-1/2" (5,1 x 10,2 x 235 cm) TP 2 x 4 x 96" (5,1 x 10,2 x 243,8 cm) CLASSIC ESTATE 12 x 12' • FOR 12' x 16', SKIP TO PAGE 43 • FOR 12' x 20', SKIP TO PAGE 44 • FOR 12' x 24', SKIP TO PAGE 45 BEGIN 1 Orient parts on top of wall frames. Measure and mark from end of boards.
fX f7!,,$/5",%23).34!,,!4)/. PARTS REQUIRED: x4 2 x 4 x 48" (5,1 x 10,2 x 121,9 cm) x2 x2 x76 x2 SP 3" (7,6 cm) STL 2 x 4 x 44-1/2" (5,1 x 10,2 x 113 cm) x16 3" (7,6 cm) TJ 2 x 4 x 92-1/2" (5,1 x 10,2 x 235 cm) TP 2 x 4 x 96" (5,1 x 10,2 x 243,8 cm) • FOR 12' x 20', SKIP TO PAGE 44 • FOR 12' x 24', SKIP TO PAGE 45 BEGIN 1 Orient parts on top of wall frames. Measure and mark from end of boards. 2 Secure from top using two 3" nails spaced every 24" (Fig. A).
fX f7!,,$/5",%23).34!,,!4)/. PARTS REQUIRED: x2 2 x 4 x 48" (5,1 x 10,2 x 121,9 cm) x2 x4 x84 x2 SP 3" (7,6 cm) STL 2 x 4 x 44-1/2" (5,1 x 10,2 x 113 cm) x16 3" (7,6 cm) TJ 2 x 4 x 92-1/2" (5,1 x 10,2 x 235 cm) TP 2 x 4 x 96" (5,1 x 10,2 x 243,8 cm) • FOR 12' x 24', SKIP TO PAGE 45 BEGIN 1 Orient parts on top of wall frames. Measure and mark from end of boards. 2 Secure from top using two 3" nails spaced every 24" (Fig. A).
fX f7!,,$/5",%23).34!,,!4)/. PARTS REQUIRED: x4 x92 x2 SP 2 x 4 x 48" (5,1 x 10,2 x 121,9 cm) 3" (7,6 cm) STL 2 x 4 x 44-1/2" (5,1 x 10,2 x 113 cm) x16 3" (7,6 cm) x2 TJ 2 x 4 x 92-1/2" (5,1 x 10,2 x 235 cm) x4 TP 2 x 4 x 96" (5,1 x 10,2 x 243,8 cm) BEGIN 1 Orient parts on top of wall frames. Measure and mark from end of boards. 2 Secure from top using two 3" nails spaced every 24" (Fig. A). 3 Secure from bottom using four 3" screws at each corner (Fig. B).
2!&4%23 12x12' 12x16' 12x20' 12x24' PARTS REQUIRED: x1 OO 2 x 3 x 69" (5,1 x 7,6 x 175,3 cm) Temp Support x14 x18 x22 x26 x12 x16 x20 x24 x144 x192 x240 x288 6 x 24" (15,2 x 61 cm) CLASSIC ESTATE 12 x 12' 2" (5,1 cm) BEGIN 1 You will build assemblies from quantities listed; Place two rafter-halves in the corner of back and side walls. The RED ENDS identify the ends to be HINT: connected at the center.
fX f2!&4%2).34!,,!4)/. PARTS REQUIRED: x28 x5 3" (7,6 cm) x2 (2) Gusset Pre-assembled (1) Gusset Pre-assembled • FOR 12' x 16', SKIP TO PAGE 48 • FOR 12' x 20', SKIP TO PAGE 49 CLASSIC ESTATE 12 x 12' • FOR 12' x 24', SKIP TO PAGE 50 BEGIN 1 Locate rafters directly over the wall studs. Check you have the measurements shown. 2 Secure end rafters using two screws at siding seam (Fig. A). 3 Secure with two 3" screws angled at each end (Fig. B).
fX f2!&4%2).34!,,!4)/. PARTS REQUIRED: x7 x36 3" (7,6 cm) x2 (2) Gusset Pre-assembled (1) Gusset Pre-assembled • FOR 12' x 20', SKIP TO PAGE 49 • FOR 12' x 24', SKIP TO PAGE 50 BEGIN 1 Locate rafters directly over the wall studs. Check you have the measurements shown. 2 Secure end rafters using two screws at siding seam (Fig. A). 3 Secure with two 3" screws angled at each end (Fig. B). FINISH CLASSIC ESTATE 12 x 16' 4 You have finished installing your rafters. Proceed to page 51.
fX f2!&4%2).34!,,!4)/. PARTS REQUIRED: x44 x9 3" (7,6 cm) x2 (2) Gusset Pre-assembled (1) Gusset Pre-assembled • FOR 12' x 24', SKIP TO PAGE 50 BEGIN 1 Locate rafters directly over the wall studs. Check you have the measurements shown. 2 Secure end rafters using two screws at siding seam (Fig. A). 3 Secure with two 3" screws angled at each end (Fig. B). FINISH 4 You have finished installing your rafters. Proceed to page 51. DIMENSIONS ARE FROM OUTSIDE OF WALL PANELS.
fX f2!&4%2).34!,,!4)/. PARTS REQUIRED: x52 x11 3" (7,6 cm) x2 (2) Gusset Pre-assembled (1) Gusset Pre-assembled BEGIN 1 Locate rafters directly over the wall studs. Check you have the measurements shown. 2 Secure end rafters using two screws at siding seam (Fig. A). 3 Secure with two 3" screws angled at each end (Fig. B). FINISH 4 You have finished installing your rafters. DIMENSIONS ARE FROM OUTSIDE OF WALL PANELS. DIMENSIONS ARE TO CENTER OF RAFTERS.
'!",%0!.%,3 PARTS REQUIRED: x4 x56 QL 1-1/2" (3,8 cm) 2 x 4 x 39" (5,1 x 10,2 x 99,1 cm) x2 x1 x1 x2 BEGIN Place center gable panel on QL primed side up as shown. 2 Mark bottom of center gable panel at center on primed side. 3 Place left panel on QL flush to center gable panel and secure using 1-1/2" nails. 4 Repeat STEP 3 for right panel. 5 Repeat STEP 1-4 for front gable panels.
'!",%).34!,,!4)/. PARTS REQUIRED: x8 3" (7,6 cm) x126 CLASSIC ESTATE 12 x 12' x1 Pre - assembled 1-1/2" (3,8 cm) x1 6 Center gable assembly on back wall and overlap back wall. Nail using 1-1/2" nails 6" apart as shown. 7 Secure rear gable connectors onto doubler using 3" screws as shown. 8 Repeat Steps 6 - 7 to attach front gable assembly. FINISH 9 You have finished installing the gable panels.
f8 f2//&0!.%,3 PARTS REQUIRED: x8 2" (5,1 cm) GAA x2 3/4" GAUGE BLOCK 7/16 x 48 x 96" (1,1 x 121,9 x 243,8 cm) • FOR 12' x 16', SKIP TO PAGE 56 CLASSIC ESTATE 12 x 12' • FOR 12' x 20', SKIP TO PAGE 59 • FOR 12' x 24', SKIP TO PAGE 62 Roof panels may cause serious injury until securely fastened. You must square the roof by attaching one panel first. You must use the panel's long edge as a lever to bring your roof into square. Commonly known as "racking". Fig.
f8 f2//&0!.%,3 PARTS REQUIRED: x144 2" (5,1 cm) x2 12-1/2" x 96" (31,8 x 243,8 cm) x2 x2 47-7/8" x 48" (121,6 x 121,9 cm) CLASSIC ESTATE 12 x 12' 3 12-1/2" x 48" (31,8 x 121,9 cm) Keep spacing between the center of each rafter at the lower edge of the panel and secure with one 2" nail into each rafter (Fig. E).
f8 f2//&0!.%,3 PARTS REQUIRED: x104 x2 x2 23-7/8" x 96" (60,6 x 243,8 cm) 23-7/8" x 48" (60,6 x 121,9 cm) x2 x2 11-7/8" x 96" (30,2 x 243,8 cm) 11-7/8" x 48" (30,2 x 121,9 cm) Attach the 23-7/8 x 96" and 23-7/8 x 48" roof panels flush to the upper panels as shown, and with the 1/2" measurement (Fig. H ). Stagger seams. Nail the roof panels using 2" nails 6" apart on edges and 12" apart inside panel.
f8 f2//&0!.%,3 PARTS REQUIRED: x8 2" (5,1 cm) GAA 3/4" GAUGE BLOCK x2 48 x 96" (121,6 x 243,8 cm) • FOR 12' x 20', SKIP TO PAGE 59 • FOR 12' x 24', SKIP TO PAGE 62 Roof panels may cause serious injury until securely fastened. You must square the roof by attaching one panel first. You must use the panel's long edge as a lever to bring your roof into square. Commonly known as "racking".
f8 f2//&0!.%,3 PARTS REQUIRED: x206 2" (5,1 cm) x4 12-1/2 x 48" (31,8 x 121,9 cm) GAA x4 x2 47-7/8 x 48" (121,6 x 121,9 cm) 3 Keep spacing between the center of each rafter at the lower edge of the panel and secure with one 2" nail into each rafter (Fig. E). NOTE: Measurements from inside of panels 24-3/8" 24" 24" 24" (61,9 cm) 24" (61 cm) (61 cm) (61 cm) 24-3/8" 24" 24" (61,9 cm) (61 cm) (61 cm) (61 cm) Move to the top of the panel and keep spacing between the center of the rafters.
f8 f2//&0!.%,3 PARTS REQUIRED: x104 x2 11-7/8 x 96" (30,2 x 243,8 cm) x4 11-7/8 x 48" (30,2 x 121,9 cm) x2 23-7/8 x 96" (60,6 x 243,8 cm) x4 23-7/8 x 48" (60,6 x 121,9 cm) 6 2" (5,1 cm) Attach the 11-7/8 x 48", 23-7/8 x 48", and 11-7/8 x 96" roof panels flush to the upper panels as shown, and with the 1/2" measurement (Fig. H ). Stagger seams. Nail the roof panels using 2" nails 6" apart on edges and 12" apart inside panel.
f8 f2//&0!.%,3 PARTS REQUIRED: x8 2" (5,1 cm) GAA 3/4" GAUGE BLOCK x2 48 x 96" (121,6 x 243,8 cm) • FOR 12' x 24', SKIP TO PAGE 62. Roof panels may cause serious injury until securely fastened. You must square the roof by attaching one panel first. You must use the panel's long edge as a lever to bring your roof into square. Commonly known as "racking". BEGIN 1 Attach panel to rafter as shown with rough side up (primed grid-line side) 3/4" (1,9 cm) from edge (Fig.
f8 f2//&0!.%,3 PARTS REQUIRED: x2 x234 2" (5,1 cm) x2 12-1/2 x 48" (31,8 x 121,9 cm) GAA 48 x 96" (121,9 x 243,8 cm) x2 x4 47-7/8 x 48" (121,6 x 121,9 cm) 3 3/4" GAUGE BLOCK 12-1/2 x 96" (31,8 x 243,8 cm) Keep spacing between the center of each rafter at the lower edge of the panel and secure with one 2" nail into each rafter (Fig. E).
f8 f2//&0!.%,3 PARTS REQUIRED: x166 x4 23-7/8 x 96" (60,6 x 243,8 cm) x2 23-7/8 x 48" (60,6 x 121,9 cm) x4 11-7/8 x 96" (30,2 x 243,8 cm) x2 11-7/8 x 48" (30,2 x 121,9 cm) 6 2" (5,1 cm) Attach the 11-7/8 x 96", 23-7/8 x 96", and 11-7/8 x 48" roof panels flush to the upper panels as shown, and with the 1/2" measurement (Fig. H ). Stagger seams. Flush Nail the roof panels using 2" nails 6" apart on edges and 12" apart inside panel.
f8 f2//&0!.%,3 PARTS REQUIRED: x8 2" (5,1 cm) GAA x2 3/4" GAUGE BLOCK 48 x 96" (121,6 x 243,8 cm) Roof panels may cause serious injury until securely fastened. You must square the roof by attaching one panel first. You must use the panel's long edge as a lever to bring your roof into square. Commonly known as "racking". BEGIN 1 Attach panel to rafter as shown with rough side up (primed grid-line side) 3/4" (1,9 cm) from edge (Fig. A) and panel flush at peak (Fig. B ).
f8 f2//&0!.%,3 PARTS REQUIRED: x4 x296 2" (5,1 cm) x2 12-1/2 x 48" (31,8 x 121,9 cm) 48 x 96" (121,9 x 243,8 cm) x4 x4 47-7/8 x 48" (121,6 x 121,9 cm) 3 12-1/2 x 96" (31,8 x 243,8 cm) Keep spacing between the center of each rafter at the lower edge of the panel and secure with one 2" nail into each rafter (Fig. E).
f8 f2//&0!.%,3 PARTS REQUIRED: x104 x4 23-7/8 x 96" (60,6 x 243,8 cm) x4 23-7/8 x 48" (60,6 x 121,9 cm) x4 11-7/8 x 96" (30,2 x 243,8 cm) x4 11-7/8 x 48" (30,2 x 121,9 cm) 6 2" (5,1 cm) Attach two 23-7/8 x 48" and two 11-7/8 x 96" roof panels flush to the upper panels as shown, and with the 1/2" measurement (Fig. H ). Stagger seams. Nail the roof panels using 2" nails 6" apart on edges and 12" apart inside panel.
#/2.%242)PARTS REQUIRED: x64 2" (5,1 cm) x4 1-3/4 x 82-1/2 x 3/8" (4,4 x 209,6 x 1 cm) x4 1-3/4 x 83-1/2 x 3/8" (4,4 x 212,1 x 1 cm) BEGIN Secure 83-1/2" (212,1 cm) corner trim under roof panel. Attach with 2" nails as shown in (Fig. A). 2 Secure 82-1/2" (209,6 cm) corner trim flush under gable panel. Attach with 2" nails as shown. 3 Repeat on other side. CLASSIC ESTATE 12 x 12' 1 FINISH 4 Proceed to installing your collar ties. Seam is flush. Caulk seam before painting trim. Fig.
fX f#/,,!24)% 12x12' 12x16' 12x20' 12x24' PARTS REQUIRED: x2 x4 x6 x8 SX 2 x 4 x 60" (5,1 x 10,2 x 152,4 cm) x4 x2 x6 x8 7/16 x 3-1/2 x 24" (1,1 x 8,9 x 61 cm) COLLAR TIE GUSSET x20 x40 x60 x80 CLASSIC ESTATE 12 x 12' 2" (5,1 cm) • FOR 12' x 12', BUILD 1 COLLAR TIE ASSEMBLY • FOR 12' x 16', BUILD 2 COLLAR TIE ASSEMBLIES • FOR 12' x 20', BUILD 3 COLLAR TIE ASSEMBLIES • FOR 12' x 24', BUILD 4 COLLAR TIE ASSEMBLIES BEGIN CLASSIC ESTATE 12 x 16' 1 Measure and mark center of Collar tie g
fX f#/,,!24)%3 PARTS REQUIRED: x6 3" (7,6 cm) x1 Pre-assembled • FOR 12' x 20', SKIP TO PAGE 68 • FOR 12' x 20', SKIP TO PAGE 69 CLASSIC ESTATE 12 x 12' • FOR 12' x 24', SKIP TO PAGE 70 BEGIN 1 Locate collar tie assembly on back of 3rd rafter from the door as shown. Check assembly is level and flush to roof panel. 2 Nail assembly to rafter with three 3" nails at each end. 3 Repeat steps 1-2 to attach collar tie to every other rafter. FINISH 4 You have finished installing your collar ties.
fX f#/,,!24)%3 PARTS REQUIRED: x12 3" (7,6 cm) x2 Pre-assembled • FOR 12' x 20', SKIP TO PAGE 69 • FOR 12' x 24', SKIP TO PAGE 70 BEGIN 1 Locate collar tie assembly on back of third rafter from the door as shown. Check assembly is level and flush to roof panel. 2 Nail assembly to rafter with three 3" nails at each end. 3 Repeat steps 1-2 to attach assembly to fifth rafter. CLASSIC ESTATE 12 x 16' FINISH 4 You have finished installing your collar ties. Proceed to page 71.
fX f#/,,!24)%3 PARTS REQUIRED: x18 3" (7,6 cm) x3 Pre-assembled • FOR 12' x 24', SKIP TO PAGE 70 BEGIN 1 Locate collar tie assembly on back of third rafter from the door as shown. Check assembly is level and flush to roof panel. 2 Nail assembly to rafter with three 3" nails at each end. 3 Repeat steps 1-2 to attach assembly to fifth and seventh rafter. FINISH 4 You have finished installing your collar ties. Proceed to page 71.
fX f#/,,!24)%3 PARTS REQUIRED: x24 3" (7,6 cm) x4 Pre-assembled BEGIN 1 Locate collar tie assembly on back of third rafter from the door as shown. Check assembly is level and flush to roof panel. 2 Nail assembly to rafter with three 3" nails at each end. 3 Repeat steps 1-2 to attach assembly to fifth, seventh, and ninth rafter. FINISH 4 You have finished installing your collar ties. Proceed to page 71.
'!",%42)PARTS REQUIRED: x80 2" (5,1 cm) x2 x2 ZJL 19/32 x 4 x 36" (1,5 x 10,2 x 91,4 cm) x2 x2 ZJR ZOL 19/32 x 4 x 60-7/8" (1,5 x 10,2 x 154,6 cm) 19/32 x 4 x 36" (1,5 x 10,2 x 91,4 cm) ZOR 19/32 x 4 x 60-7/8" (1,5 x10,2 x 154,6 cm) BEGIN 1 3 Secure to wall using 2" (5,1 cm) finish nails 12" (30,5 cm) apart. Nail through gable trim and panels into rafter. 4 Repeat Steps 1-3 to secure the right gable trim ZOR and ZJR. 6 Repeat Steps 1-4 to install front gable trim.
,/&4*/)34!33%-",9 PARTS REQUIRED: x4 x28 3" (7,6 cm) TP 2 x 4 x 96" (5,1 x 10,2 x 243,8 cm) x4 SP 2 x 4 x 48" (5,1 x 10,2 x 121,9 cm) CLASSIC ESTATE 12 x 12' BEGIN 1 Ensure parts TP and SP are aligned perfectly on a flat surface. Spread glue across SP and TP as shown. 2 Assemble joist with 3" (7,6 cm) nails in a staggered pattern. 3 Turn assembled joist over and repeat staggered nail pattern. 4 Support and drill a 7/16" (1,1 cm) hole through each end of each joist (Fig A).
,/&4*/)34).34!,,!4)/. PARTS REQUIRED: x1 x16 3" (7,6 cm) PT 2 x 3 x 96" (5,1 x 7,6 x 243,8 cm) x1 x4 5-1/2" (14 cm) Hexbolt, 2 washers and locknut ZJ 2 x 3 x 48" (5,1 x 7,6 x 121,9 cm) x2 LOFT JOIST ASSEMBLY CLASSIC ESTATE 12 x 12' BEGIN 1 Measure, mark and locate ZJ and PT flush to bottom of top plate and against back wall studs. Secure with 3" (7,6) nails at each backwall stud.
,/&40!.%,3 PARTS REQUIRED: x44 2" (5,1 cm) x1 40-7/8 x 48" (103,8 x 121,9 cm) x1 CLASSIC ESTATE 12 x 12' 48 x 96" (121,9 x 243,8 cm) BEGIN Install loft panels centered over loft joists and ledger board. Secure with 2" (5,1 cm) nails 8" (20,3 cm) apart on edges and 16" (50,6 cm) inside panels. 1 NOTE: There will be a gap of approximately 1/2” (1,3 cm) on either side of installed loft panels. FINISH You have finished installing your Loft.
$//23 PARTS REQUIRED: x1 x2 OO 1-1/4" (3,2 cm) 2 x 3 x 69" (5,1 x 7,6 x 175,3 cm) x4 GAA 3" (7,6 cm) 3/4" GAUGE BLOCK HINT: x1 x1 Left Door Look for 3/8" SPACER attached to doors. Right Door CLASSIC ESTATE 12 x 12' BEGIN 1 Orient parts as shown on flat surface. 3/8" offset is to top. Look for red (right) and green (left) on hinge board. 2 Attach temporary support OO with 3" screws. Tighten securely. Attach temporary support GAA at bottom with 1-1/4" screws. Tighten securely.
$//23 PARTS REQUIRED: x7 x1 x6 3" (7,6 cm) OO 2" (5,1 cm) 2 x 3 x 69" (5,1 x 7,6 x 175,3 cm) Attach temporary support OO as a ledger board flush under wall panels for doors to rest on, using three 3" screws (Fig. A). CLASSIC ESTATE 12 x 12' 3 OO CLASSIC ESTATE 12 x 20' CLASSIC ESTATE 12 x 16' Flush against wall panels. Fig. A 4 OO Center doors on right edge of groove as shown (Fig. B). Check ledger board is still flush under panels.
$//27%!4(%2342)0 x12 PARTS REQUIRED: x2 2" (5,1 cm) OO 2 x 3 x 69" (5,1 x 7,6 x 175 cm) BEGIN With left door closed, center a weatherstrip OO vertically on the left door in the door opening (Fig. A). OO will offset the left door 1" OUT past the door trim 1" (Fig. B). 2 Secure OO using five 2" (5,1 cm) screws through outside trim into OO (Fig. B). 3 On right door center OO vertically in door opening (Fig. A). OO will offset the right door 1" IN from the door trim (Fig. C).
$//23 x8 PARTS REQUIRED: 2" (5,1 cm) AHR/AHL x2 19/32 x 3 x 62" (1,5 x 7,6 x 157,5 cm) x1 x2 ZJ 19/32 x 3 x 72" (1,5 x 7,6 x 182,9 cm) x62 AH 19/32 x 3 x 26 5/8" (1,5 x 7,6 x 67,6 cm) 3/4" (1,9 cm) BEGIN Reinforce the door trim using 3/4" (1,9 cm) screws through door panel into trim (Fig. A). Locate screws as shown in Fig. B. Use two screws at seams. CLASSIC ESTATE 12 x 16' CLASSIC ESTATE 12 x 12' 1 3/4" (1,9 cm) Screws 14" (35,6 cm) Approximately Two 3/4" (1,9 cm) Screws Fig. A Fig.
$//23 PARTS REQUIRED: x11 x4 3/4" (1,9 cm) x12 x1 3/4” (1,9 cm) 64" Metal Threshold BEGIN 1 Center Door Threshold between door opening. 2 Secure Threshold using twelve 3/4" (1,9 cm) screws. CLASSIC ESTATE 12 x 12' FINISH 3 You have finished installing your door Threshold. CLASSIC ESTATE 12 x 16' 3/4" (1,9 cm) Screws BEGIN 1 FINISH 2 You have finished installing your decorative door hinges.
$//2(!2$7!2% PARTS REQUIRED: 5/16" (0,8 cm) Drill Bit x2 x8 1" (2,5 cm) CLASSIC ESTATE 12 x 12' BEGIN 1 Place bolts onto OO in open position with bolt ends 1/4" (0,6 cm) down from frame (Fig A), and 1/2" (1,3 cm) up from floor (Fig B). Bolt is open when loop is contacting base. 2 Mark and pre-drill holes for screws. Install bolt with screws supplied. Drill 5/16" (0,8 cm) hole deep enough for bolt to slide into. Fig. A 5/16" (0,8 cm) drill for bolt 1" (2,5 cm) deep.
$//2(!2$7!2% PARTS REQUIRED: x2 x1 1-1/2Ž (38 mm) 1/4" (0,6 cm) 1/2" (1,3 cm) Drill Bits Measure and mark position on right door as shown. 4 Pre-drill 1/4" hole at mark. Finish hole with 1/2" drill bit. 5 Position hardware in hole and secure with screws as shown. CLASSIC ESTATE 12 x 12' 3 CLASSIC ESTATE 12 x 16' TOP VIEW 1-1/2" (3,8 cm) 1/4" Pre-drill and 1/2" Drill-through. 1/2" 1,3 cm 35-3/4" 90,8 cm 1-1/2" 3,8 cm CLASSIC ESTATE 12 x 20' SIDE VIEW Set Screw INSTALL ON RIGHT DOOR.
:,1'2: x14 PARTS REQUIRED: x8 x4 KX 2" (5,1 cm) 3/4" (1,9 cm) 7/64" (0,3 cm) 19/32 x 3 x 21-3/4" (1,5 x 7,6 x 55,2 cm) CLASSIC ESTATE 12 x 12' x1 ¸1 BEGIN 2 Position window on front gable as shown and secure with 3/4" screws. Seal window with high quality paintable exterior caulk. CLASSIC ESTATE 12 x 16' (2) 3/4" (1,9 cm) Screws NOTE: Caulk seam with high-quality paintable exterior caulk before installing trim. Outside view CLASSIC ESTATE 12 x 20' Level 3 Center trim over window.
6%.4 • Follow directions provided by manufacturer and these instructions. x12 x1 1/2" (13 mm) x12 16 x 8" ( 40,6 x 20,3 cm) BEGIN 1 Locate and mark for two vents in side walls as shown. (1) at top and (1) at bottom CLASSIC ESTATE 12 x 12' Cut out marked openings Caulk behind vent flanges 2 Secure using 1/2" (1,3 cm) screws 14" (35,6 cm) FINISH 3 You have finished installing your vents.
0!).4 #!5,+ - NOT INCLUDED - • Use acrylic latex caulk that is paintable. Caulk at all horizontal and vertical seams, between the trim and walls, and all around the door trim. • Use a high quality exterior acrylic latex paint. When painting your building, there are a few key areas that can be easily overlooked that must be painted: • Bottom edge of all siding and trim • Inside of doors and all 4 edges Note: Prime all un-primed exterior wood before painting. (Follow directions provided by manufacturer.
3().',%3 - NOT INCLUDED • Follow directions provided by manufacturer and these instructions. Familiarize yourself with a 3-Tab Shingle. Notch 3().',%.!),0!44%2. 1" (2,5 cm) 1/2" (1,3 cm) Sealing Strip Notch 1" (2,5 cm) Half A Rain Slot Full Rain Slot NAILS NEVER DRIVE FASTENERS INTO OR ABOVE SEALING STRIPS. BEGIN 1 Install first starter row upside down and color up with a 1" overhang at back and bottom of roof panel. Use (4) nails per shingle.
3().',%3 continued... 2 2 Beginning at front of shed, install first row of shingles with notch at 1" past roof edge or flush with drip edge. Roof Deck FRONT OF SHED 1" (2,5 cm) BACK OF SHED Flush with starter row. Notch - or Drip Edge Flush with starter row. Notch 3 Install second row of shingles flush at top of first row's rain slots. Ensure 1" overhang or flush to drip edge at front, stagger each row. FRONT OF SHED BACK OF SHED Bend in roof 1" (2,5 cm) Notch Flush with rain slots.
3().',%3 continued... 5 Continue installing rows of shingles to the peak. At the peak make sure there is a maximum of 5" or less to the rain slot, as shown below. If shingles overlap at ridge cut to peak with a utility knife. Cut Off. 5" (12,7 cm) MAX. CUT Top of rain slot. 5" (12,7 cm) or less. • If more than 5" to rain slot you must install another row of shingles. 6 Repeat steps 1 - 7 to shingle the opposite side of your roof. Trim shingles at ridge.
3().',%3 2)$'%#!0 • You will finish off the top of the roof with a ridge cap made from shingles. BEGIN 1 Cut shingles into THREE pieces. Hint: Use cut-off pieces first. 2" (5,1 cm) 2" (5,1 cm) 2" (5,1 cm) 2" (5,1 cm) 2" (5,1 cm) 2" (5,1 cm) Score shingle, then snap-off angled cut. Weather Seal 12x16' 12x20' 12x24' 28 to 30 Pieces 38 to 40 Pieces 48 to 50 Pieces 57 to 60 Pieces Top of slot.
3().',%3 2)$'%#!0 continued... 4 Continue installing ridge cap to back of roof. 5 Make sure there is 4" between the shingle-color and edge of shingles. 4" (10,2 cm) 6 Trim cap off flush to shingles When you have 4" minimum of shingle color cut one piece to cap your roof. Cut at top of rain slot. Cap 7 Install flush to shingles. Flush to shingles (2) Nails per side. FINISH 8 You have finished your ridge cap.
WARRANTY REGISTRATION Please complete your warranty registration to properly validate your warranty. Register your product online at: www.OnlineWarranty.net LIMITED CONDITIONAL WARRANTY* Backyard Storage Solutions, LLC warrants the following: 1. Every product is warranted from defects in workmanship and manufacturing for 1 year. 2. All accessories, hardware and metal components are warranted for 2 years. 3. All Oriented Strand Board (OSB) is warranted for 2 years 4.