User Guide

11
Heat Controller, Inc. 7602-443 COMMUNICATING, PROGRAMMABLE THERMOSTAT User Manual
NOTE: The thermostat must be con gured for
programmable mode by installer to access the
Programmed Demand Reduction settings.
5.6.5.5.1 PROGRAMMED DEMAND
REDUCTION MODE
Through Programmed Demand Reduction
Mode, you can set the unit’s limited operation
during the Programmed Demand Reduction
schedule.
Adjust the Programmed Demand Reduction
Mode settings using the up/down arrow buttons.
Press the center button to save changes.
Adjust the Programmed Demand Reduction
Whole House Dehumidi cation settings using
the up/down arrow buttons. Press the center
button to save changes.
Suspend Whole House Dehumidi cation
(default): During the scheduled
Programmed Demand Reduction
time (section 5.6.5.5.4), Whole House
Dehumidi cation is turned off, regardless of
the dehumidi cation demand.
Allow Whole House Dehumidi cation:
During the scheduled Programmed Demand
Reduction time (section 5.6.5.5.4), Whole
House Dehumidi cation will operate
normally.
NOTE: The thermostat must be con gured
for humidity control by installer and the
DXM2 must be con gured for Whole House
Dehumidi cation operation to access Demand
Reduction Whole House Dehumidi cation
settings.
5.6.5.5.3 FAN - PROGRAMMED DEMAND
REDUCTION
This option allows for the customization of
fan settings during the Programmed Demand
Reduction schedule.
DEMAND REDUCTION
OPTION FOR
PROGRAM OPERATION
SAVE
NO AUXILIARY HEAT
NO 2ND STAGE COMP
PREVIOUS
SELECT OPTION
NO DEMAND REDUCTION
No Demand Reduction (default): During
the scheduled Programmed Demand
Reduction time (section 5.6.5.5.4), the
system operates normally based on the
setpoints.
• No Auxiliary Heat: During the scheduled
Programmed Demand Reduction time
(section 5.6.5.5.4), auxiliary heat will not
be activated, regardless of the heating
demand.
No 2nd Stage Compressor: During the
scheduled Programmed Demand Reduction
time (section 5.6.5.5.4), the compressor is
limited to only part load (1st stage) operation
and auxiliary heat is turned off, regardless of
system demand.
NOTE 1: The thermostat must be con gured for
auxiliary heat by installer to access the Demand
Reduction NO AUXILIARY HEAT option.
NOTE 2: The thermostat must be con gured
for Multistage by installer to access the Demand
Reduction NO 2nd STAGE COMP option.
5.6.5.5.2 Whole House Dehumidi cation -
PROGRAMMED DEMAND REDUCTION
This option allows for the customization
of Whole House Dehumidi cation.
(Dehumidi cation, optional) operation during the
Programmed Demand Reduction schedule.
PROGRAMMED DEMAND
REDUCTION OPERATION
FOR CLIMADRY
SAVE
ALLOW CLIMADRY
PREVIOUS
SELECT OPTION
WHEN DEMAND REDUCTION
IS ACTIVE
SUSPEND CLIMADRY
PROGRAMMED DEMAND
REDUCTION FAN
OPERATION
SAVE
PREVIOUS
SELECT OPTION
ALLOW CONSTANT FAN
WHEN DEMAND REDUCTION
IS ACTIVE
AUTO FAN ONLY
Adjust the Programmed Demand Reduction
Fan settings using the up/down arrow buttons.
Press the center button to save changes.