User Guide

3
Heat Controller, Inc. 7602-443 COMMUNICATING, PROGRAMMABLE THERMOSTAT User Manual
1.0 Operating Mode Selection
To set the Operating Mode of your thermostat, navigate to the
MODE user option on the Home Screen using the left/right
arrow buttons and press the center button. The Operating
Mode Menu shows the possible Operating Modes with the
currently active Operating Mode highlighted. Use the up/
down arrow buttons to select the desired Mode for use and
press the center button to save your selection. The following
Modes are available:
Off (default): No equipment operation
Auto: Thermostat automatically controls the
equipment to run either heating or cooling
depending on the setpoints.
Cool: Thermostat controls cooling equipment
depending on Cooling setpoint
Heat: Thermostat controls heating equipment
depending on Heating setpoint
Emergency Heat: Thermostat controls auxiliary
heat. No compressor operation.
69
°
RH 41%
10/13/11 8:27 AM
FAN AUTO
HUMID ON
AUTO
SETPOINT
HEAT 62
COOL 82
RH
TEMP
FAN
MENU
MODE
AUTO
OPERATING MODE MENU
SAVE
OFF
COOL
HEAT
EMERGENCY
PREVIOUS
CHANGE
MODE
HEAT
The 7602-443 Communicating, Programmable Thermostat is the perfect compliment to your geothermal heat pump system
and represents a signi cant advancement in thermostat communicating technology. For homeowners, the 7602-443 provides
highly customizable climate control features designed to maximize comfort and reduce the amount of energy consumed by
your geothermal heat pump system. Please read the following instructions carefully to maximize the comfort and cost-saving
potential of your geothermal heat pump system.
Menu Navigation Shortcuts
1. From any other screen than the home screen, hold down
the left arrow button (
) to return to the home screen.
2. From the home screen, hold the left arrow button (
) to
go to the System Status screen.
PREVIOUS
SYSTEM STATUS
LT1 TEMP 38.1
LT2 TEMP 79.9
COMP DISCHARGE 157.7
HOT WATER EWT 121.5
LEAVING AIR 75.1
LEAVING WATER 73.3
ENTERING WATER 78.5
ECM BLOWER RPM 550
ECM TARGET CFM 800
ECM BLWR STATIC 0.5
PUMP WATTS 140
FLOW RATE GPM 7.4
PUMP SPEED 60%