USER MANUAL 7602-443 Communicating, Programmable Thermostat Heat Controller, Inc. • 1900 Wellworth Ave. • Jackson, MI 49203 • (517)787-2100 • www.heatcontroller.
TABLE OF CONTENTS Section Title Page Menu Navigation Shortcuts 3 1.0 Operating Mode Selection 3 2.0 Temperature Adjustment 4 3.0 Fan Mode Selection 4 4.0 Humidity Level Adjustment 5 5.0 Main Menu Options Overview 6 5.1 Date and Time 7 5.2 Hold 7 5.3 Program 9 5.4 Fan 9 5.5 Mode 9 5.6 Other Settings 10 5.7 Security Lockout 14 5.8 Night Setback 14 6.0 Service Needed 15 7.
Heat Controller, Inc. 7602-443 COMMUNICATING, PROGRAMMABLE THERMOSTAT User Manual The 7602-443 Communicating, Programmable Thermostat is the perfect compliment to your geothermal heat pump system and represents a significant advancement in thermostat communicating technology. For homeowners, the 7602-443 provides highly customizable climate control features designed to maximize comfort and reduce the amount of energy consumed by your geothermal heat pump system.
User Manual 7602-443 COMMUNICATING, PROGRAMMABLE THERMOSTAT 2.0 Temperature Adjustment 10/13/11 Heat Controller, Inc. 8:25 AM FAN AUTO To adjust the temperature on the thermostat, use the left/ right arrow buttons to select the TEMP user option on the Home Screen and then press the center button or press the up or down arrow key. The Temperature Adjustment Display appears and shows either one (in Heat, Cool, or Emergency Heat modes) or both (in Auto mode) temperature setpoints.
Heat Controller, Inc. 7602-443 COMMUNICATING, PROGRAMMABLE THERMOSTAT 4.0 Humidity Level Adjustment 10/12/11 User Manual 5:22 PM FAN AUTO NOTE 1: The thermostat must be configured by installer for humidity control to access the humidity setpoint(s). HUMID ON RH 38% ° 70 To adjust the Relative Humidity level on your thermostat, use the left/right arrow buttons to select the RH user option on the Home Screen and then press the center button.
User Manual 7602-443 COMMUNICATING, PROGRAMMABLE THERMOSTAT Heat Controller, Inc. 5.0 Main Menu Options Overview MENU 5.1 DATE AND TIME 5.1.1 AUTO DAYLIGHT SAVING 5.1.2 SET DATE AND TIME 5.1.3 DISPLAY DATE AND TIME 5.2 5.3 5.4 5.5 5.6 HOLD PROGRAM FAN MODE SETTINGS 5.6.1 SCREEN SETTINGS 5.6.1.1 Fahrenheit or Celsius 5.6.1.2 12 or 24 Hour Clock 5.6.1.3 Language 5.6.1.4 Contrast 5.6.1.5 Backlight On Time 5.6.1.6 Date Display 5.6.2 OFFSETS 5.6.2.1 Temperature Offset 5.6.2.2 Anticipator 5.6.2.
Heat Controller, Inc. 7602-443 COMMUNICATING, PROGRAMMABLE THERMOSTAT 5.0 Main Menu 10/13/11 8:27 AM Access main menu by selecting MENU on the main screen. FAN AUTO RH 40% 5.1 DATE AND TIME The thermostat can be programmed for daylight savings, date and time, and to display date and time on the main screen. ° 69 5.1.1 AUTO DAYLIGHT SAVING When enabled, the thermostat automatically adjusts the time for daylight savings time. OFF RH TEMP MODE FAN MENU 5.1.
User Manual 7602-443 COMMUNICATING, PROGRAMMABLE THERMOSTAT • Heat Setpoint (default current Heat Setpoint): valid range: 55°F to Maximum Heating Setpoint Limit (section 5.6.8) • Cool Setpoint (default current Cool Setpoint): valid range: Minimum Cooling Setpoint Limit (section 5.6.8) to 95°F Heat Controller, Inc. HOLD THIS TEMPERATURE UNTIL 5:00 PM HEAT NOTE: The thermostat forces a 2°F “dead-band” between the Heating and Cooling setpoints.
7602-443 COMMUNICATING, PROGRAMMABLE THERMOSTAT Heat Controller, Inc. 5.3 PROGRAM The Program Display Mode includes options to copy schedules as well as create/edit schedules for individual days or schedules for groups of days. User Manual MAIN MENU SET DATE AND TIME HOLD PROGRAM FAN MODE SETTINGS SECURITY LOCKOUT 5.3.1 CREATE / EDIT SCHEDULE This function allows you to set the time, heat setting, cool setting, and fan operation for each program schedule event of the day.
User Manual 7602-443 COMMUNICATING, PROGRAMMABLE THERMOSTAT 5.6 OTHER SETTINGS 5.6.1 SCREEN SETTINGS Adjust the Screen settings using the up/down arrow buttons. Press the center button to save changes.
Heat Controller, Inc. 7602-443 COMMUNICATING, PROGRAMMABLE THERMOSTAT NOTE: The thermostat must be configured for programmable mode by installer to access the Programmed Demand Reduction settings. PROGRAMMED DEMAND REDUCTION OPERATION FOR CLIMADRY 5.6.5.5.1 PROGRAMMED DEMAND REDUCTION MODE Through Programmed Demand Reduction Mode, you can set the unit’s limited operation during the Programmed Demand Reduction schedule.
7602-443 COMMUNICATING, PROGRAMMABLE THERMOSTAT User Manual • • Auto Fan Only (default): During the scheduled Programmed Demand Reduction time (section 5.6.5.5.4), only auto fan mode is allowed. Allow Continuous Fan: During the scheduled Programmed Demand Reduction time (section 5.6.5.5.4), the fan will operate normally. Heat Controller, Inc.
Heat Controller, Inc. 7602-443 COMMUNICATING, PROGRAMMABLE THERMOSTAT • Maximum Heating (default 95°F): valid range: 60 to 95°F (in 1°F increments) • Minimum Cooling (default 55°F): valid range: 55 to 80°F (in 1°F increments) 5.6.7.2 TEMPERATURE STATUS Temperature Status mode allows the user to view the status of all temperature sensor readings including onboard and remote sensors.
User Manual 7602-443 COMMUNICATING, PROGRAMMABLE THERMOSTAT Adjust the Demand Reduction Whole House Dehumidification settings using the up/down arrow buttons. Press the center button to save changes. • Suspend Whole House Dehumidification (ClimaDry) (default): While the assigned Demand Reduction input is active, Whole House Dehumidification is turned off, regardless of the dehumidificaiton demand.
Heat Controller, Inc. 7602-443 COMMUNICATING, PROGRAMMABLE THERMOSTAT 5.8.3 NIGHT SETBACK DEMAND REDUCTION Through Night Setback Demand Reduction Mode, you can set the unit’s limited operation while Night Setback is active. User Manual 5.8.5.1 NIGHT SETBACK HUMIDITY CONTROL If the Night Setback Dehumidification Mode is set to ON, the thermostat will prompt for Night Setback Humidity Setpoints. Adjust the Night Setback Humidity setpoints using the up/down arrow buttons.
Revision History Date Page # 17 Sept.