User Guide

Operation
Details
0
(1)
The
function
of
main
control
1.
Time
delay
Safety
Control
"
3min.;
The
compressor
operation
is
delayed
for
3
minutes
to
balance
the
pressure
of
cycle.
(Protection
of
compressor)
"
5sec.;
The
indoor
fan
Is
delayed for
5
seconds,
when
operating
initially,
to
prevent
noises
occurred
by
the
vertical
louver
and
wind.
"
2min.;
The
reversing
valve
is
delayed
for
2
minutes
to
prevent
the
refrigerant-gas
for
abnormal noise
when
the
heating
operation
Is
OFF
or
switched
to
the
other
operation
mode
while
compressor
is
off.
While
compressor
Is
running,
it
takes
3-5
seconds
to
switch.
2.
Airflow
Direction
Control
"
This
function
is
to
swing
the
vertical
louver
up
and
down
automatically
and
to
set
it
at
a
fixed
position.
"
The
procedure
is
as
the
following.
1
st
;
Press the
ON/OFF
Button
to
operate
the
unit.
2nd;
Press
the
Airflow
Direction
Control
Button
to
swing
the
vertical
louver
up
and
down
automatically.
3nd
;
Repress
the
Airflow
Direction
Control
Button
to
set
the
vertical
lower
at
a
fixed
position.
<9k,1210
<18k,
2410
Ho'R°ne10
HMxonW
0
ý.
Coofipl
145'
115'
9(
seam
O7"ý,g
V2
C
91aý)
Smog
pmm
2
C9(am)
3
He
a,3
4
4
Heattg
Heo
g
5 5
B
7
5
7
3.
Cooling
Operation
Mode
"
When
selecting
the
Cooling()
Mode
Operation,
the
unit
will
operate
according
to
the
setting
by
the
remote
controller
and
the
operation
diagram
is
shown
below.
INTAKE
AIR
TEMP.
°
SETTING
TEMP.
+1 F
(Compressor
ON)
°
SETTING
TEMP.
-1
F
(Compressor
OFF)
More
than
More
than
3
minutes
3
minutes
INDOOR
FAN
SPEED
Selecting
fan
speed
Low
Selecting
fan
speed
Low
Selecting
fan
speed
COMPRESSOR
ON
OFF
ON
OFF
ON
Protection of
the
Indoor
heat
exchanger
from
frosting
"
Compressor
and
outdoor
fan
stop
when
indoor
pipe
temperature
is
below
32°F
and
restart
at
the
pipe
temperature
is
above
45°F.
-14-
"