INSTALLATION MANUAL 7602-443 Communicating, Programmable Thermostat Heat Controller, Inc. • 1900 Wellworth Ave. • Jackson, MI 49203 • (517)787-2100 • www.heatcontroller.
TABLE OF CONTENTS Section Title Page Safety/Installation Considerations 3 1.0 User Menu Settings 4 2.0 Installer Menu Settings 6 2.1 Installer Menu Settings Access 6 Thermostat Configuration 6 System Configuration 7 3.1 Airflow Selection 7 3.2 Option Selection 7 3.3 Unit Configuration 8 3.4 Valve Configuration 8 3.5 Multi-Unit Configuration 9 Accessory Configuration 10 4.1 Air Filter 10 4.2 Humidifier 10 4.3 UV Lamp 10 4.4 Air Cleaner 10 5.
Heat Controller, Inc. 7602-443 COMMUNICATING, PROGRAMMABLE THERMOSTAT The 7602-443 Communicating, Programmable Thermostat is the perfect compliment to a Geothermal Heat Pump System and represents a significant advancement in thermostat communicating technology. For homeowners, the 7602443 provides highly customizable climate control features designed to maximize comfort and reduce the amount of energy consumed by the Geothermal Heat Pump System.
Installation Manual 7602-443 COMMUNICATING, PROGRAMMABLE THERMOSTAT • 1.0 User Menu Settings • 1.1 OFFSETS If you find that the temperature displayed on the thermostat does not accurately represent the room temperature where the thermostat is located, this offset function compensates for the difference. The thermostat will apply an offset between what temperature the thermostat is measuring versus the temperature that is displayed. • Heat Controller, Inc.
7602-443 COMMUNICATING, PROGRAMMABLE THERMOSTAT Heat Controller, Inc. 1.4 DEMO MODE Demo mode is designed to showcase heat pump operation when the unit is connected to an above ground water loop with the supply air being blown directly over the water loop. Installation Manual The starting mode (heating or cooling) depends on the loop temperature at the time when Demo Mode is entered. The unit will operate in heating or cooling based upon the following algorithm. Start in Cooling Mode 1.4.
Installation Manual 7602-443 COMMUNICATING, PROGRAMMABLE THERMOSTAT 2.2.1 STAGING Adjust the staging option using the up/down arrow buttons. Press the center button to save changes. • Single Stage – for control of a single stage compressor applications • Multi-Stage (default) – for control of multistage compressor applications 2.0 Installer Menu Settings 2.1 Heat Controller, Inc.
602-443 COMMUNICATING, PROGRAMMABLE THERMOSTAT Heat Controller, Inc. 2.2.3 PROGRAMMING Adjust the Programming options using the up/down arrow buttons. Press the center button to save changes. • Programmable (default) – enables 7-day programming • Non-Programmable – disables 7-day programming • Night Setback – enables night setback programming NOTE: When the thermostat is configured for nonprogrammable mode, the Display Date and Time setting defaults to NO.
7602-443 COMMUNICATING, PROGRAMMABLE THERMOSTAT Installation Manual • Compressor ASCD (Anti-Short Cycle Delay (default stored in control) – valid range: 5 to 8 (in 1 minute increments) 3.4 VALVE CONFIGURATION Configure temperature differentials at the thermostat for Integrated Variable Speed Water Flow Control units with a motorized modulating valve. NOTE 1: The Compressor Anti-Short Cycle Delay setting provides equipment protection by forcing the compressor to wait a few minutes before restarting.
Heat Controller, Inc. 7602-443 COMMUNICATING, PROGRAMMABLE THERMOSTAT 3.5 MULTI-UNIT CONFIGURATION If multiple units are connected to one ATC thermostat upon unit start-up, the thermostat will automatically register the serial numbers of all units connected to it. Installation Manual 3.5.2 MULTI-UNIT OPTION SELECTION In section 3.
Installation Manual 7602-443 COMMUNICATING, PROGRAMMABLE THERMOSTAT Adjust the Air Cleaner Reminder settings using the up/down arrow buttons. Press the center button to save changes. • Cumulative Run Time (default Off) – valid range: Off, 400 to 3600 hours (in 100 hour increments) • Calendar Time (default Off) – valid range: Off, 3 to 24 months (in 3 month increments) 4.
Heat Controller, Inc. 7602-443 COMMUNICATING, PROGRAMMABLE THERMOSTAT Installation Manual 9.0 Service Mode cooling stages for operation. This logic will keep all active heating or cooling stages energized until the demand is fully satisfied (see NOTE 2). SERVICE MODE NOTE 1: The Proportional Integral options require first stage heating or cooling to be active for a minimum of 5 minutes, before energizing second stage when configured for multi stage operation.
7602-443 COMMUNICATING, PROGRAMMABLE THERMOSTAT Installation Manual 9.2 CONTROL DIAGNOSTICS Control Diagnostics mode allows the service personnel to view the status of all physical inputs, switches, temperature sensor readings, as well as the operational status of the pump at the thermostat. Heat Controller, Inc. 9.
Heat Controller, Inc. 7602-443 COMMUNICATING, PROGRAMMABLE THERMOSTAT Installation Manual 9.4 FAULT HISTORY Fault History mode displays the five most recent stored fault codes for the connected communicating control (DXM2). 9.4.2 Flow Conditions Displays detailed blower and valve position readings that were recorded at the time the fault occurred. Navigate between control fault codes using the up/down arrow buttons. Press the center button to view more information about the highlighted fault code.
Installation Manual 7602-443 COMMUNICATING, PROGRAMMABLE THERMOSTAT 9.4.5 Possible Causes Possible causes as to why the fault occurred Heat Controller, Inc. CONTROL DIAGNOSTICS HE024 HE024 HE036 NOTE: If multiple units are connected to one thermostat, refer to section 9.7. SN-----1234 SN-----5678 SN-----9012 POSSIBLE FAULT CAUSES LOW WATER COIL TEMP LOW WATER TEMP - HTG LOW WATER FLOW - HTG PREVIOUS LOW REFRIG CHARGE - HTG INCORRECT LT1 SETTING SELECT 9.
Heat Controller, Inc.
Revision History Date Page # 17 Sept.