Specification Sheet

Saf-T Vent
®
EZ Seal
130 Industrial Boulevard • Turners Falls, MA 01376
Phone 800 772 0739 • Fax 413 863 4803 • www.heat-fab.com
SINGLE WALL AL 29-4C
®
SPECIAL GAS VENT
6
Heatfab
E
F
G
C
D
B
A
Tees, Boot Tees, & Covers:
Part Number DIM - A DIM - B DIM - C DIM - D DIM - E DIM - F DIM - G
Out In Tap Installed Centerline Installed Installed Distance
Nominal Diameters Length of Tap to Depth from Tap to
Outlet Outlet Centerline
9316B 3 3 3 13.5 8.5 9.5 8.0
9416B 4 4 4 16.5 11.0 12.5 10.5
9516B 5 5 5 17.5 11.5 14.0 11.5
9616B 6 6 6 18.5 12.0 15.0 12.0
9664B 6 6 4 16.5 11.0 15.0 12.0
9716B 7 7 7 19.5 12.5 16.0 12.5
9816B 8 8 8 20.5 13.0 17.0 13.0
9916B 9 9 9 21.5 13.5 18.0 13.5
91016B 10 10 10 22.5 14.0 19.0 14.0
910104B 10 10 4 16.5 11.0 19.0 14.0
910106B 10 10 6 18.5 12.0 19.0 14.0
910108B 10 10 8 20.5 13.0 19.0 14.0
91216B 12 12 12 24.5 15.0 21.0 15.0
912124B 12 12 4 16.5 11.0 21.0 15.0
912126B 12 12 6 18.5 12.0 21.0 15.0
91416B 14 14 14 26.5 16.0 23.0 16.0
91616B 16 16 16 28.5 17.0 25.0 17.0
Boot Tee
Boot Tee Use vertically or horizontally to add appliances into a common-vent system. When installed horizontally, the
male end of the tee body may be capped off with a tee cover to allow for future appliances. When used in conjunction with a
drain tee cover, the boot tee will effectively transition a vent system from a horizontal to a vertical orientation while allowing for
proper condensate drainage. The pressure drop for this fitting is equivalent to 15 feet of vent. Other diameter configurations may
be available; please contact Heat-Fab’s Engineering Team to discuss your special needs.