Specification Sheet

Saf-T Vent
®
EZ Seal
130 Industrial Boulevard • Turners Falls, MA 01376
Phone 800 772 0739 • Fax 413 863 4803 • www.heat-fab.com
SINGLE WALL AL 29-4C
®
SPECIAL GAS VENT
23
Heatfab
E
BA
C
D
A
B
F
Wall Penetration Assembly - without Screen Use to penetrate any combustible or non-combustible
wall. This part is a thimble only and does not include any vent. Order enough vent to pass through the thimble and extend at least
4 inches beyond a combustible building sheathing. The vent system may be terminated using any terminal Listed for use with
the appliance. The design also allows a vent system to pass through a wall in order to install the vent up the outside of a building.
The assembly may be painted to match the exterior decor.
Part DIM - A DIM - B DIM - C DIM - D DIM - E DIM - F
Number Nominal Outer Tube Face Plate Face Plate Overall Wall
Diameter Diameter Width Height Length Opening
5391CI 3 6 16 15 18.5 8
5491CI 4 7 16 15 18.5 9
5591CI 5 8 16 15 18.5 10
5691CI 6 9 16 15 18.5 11
5791CI 7 10 17 16 18.5 12
5891CI 8 11 18 17 18.5 13
5991CI 9 12 18 17 18.5 14
51091CI 10 13 19 18 18.5 15
51291CI 12 15 22 21 18.5 17
51491CI 14 17 24 23 18.5 19
51691CI 16 19 25 24 18.5 21
Thimbles & Penetrations:
Wall Penetration Assembly - without Screen