Specification Sheet

1. Connecting to an Appliance Flue Collar
If the flue collar that comes with the appliance has Heat-fab’s integral red seal, you may
attach EZ Seal pipe and fittings directly to it. Make the joint as described in the EZ Seal
installation instructions (Pub # PI-EZ).
If the flue collar has Heat-fab’s female end (with the 3 tabs) but does not have the integral
red seal, you will need to use an approved high-temperature RTV silicone sealant to make
the joint between the flue collar and the first piece of EZ Seal. The rest of the system can be
sealant-free if it is all EZ Seal.
EZ Seal IS Compatible with Existing Heat-fab Products. Here’s how:
Connecting Saf-T Vent
®
EZ Seal to Appliances and
Other Saf-T Vent Products
©2001 Heat-fab, Inc. Saf-T Vent is a registered trademark of Heat-fab, Inc.
Appliance flue collar has Heat-fab’s integral red seal.
No sealant required.
Appliance flue collar has Heat-fab’s female expand
but no integral red seal.
Sealant is required to attach to flue collar.