Specification Sheet

3. Connecting EZ Seal to Saf-T Vent GC (single-wall) or Saf-T Vent CI (double-wall)
Saf-T Vent GC and Saf-T Vent CI lack the integral red seal. When you connect EZ Seal to
them you will need to use an approved high-temperature RTV silicone sealant. Follow the
procedure outlined in the GC or CI installation instructions (Pub # PI-VBH or PI-CIINS).
4. Attaching Saf-T Vent Terminations to EZ Seal
Existing Saf-T Vent Terminations (rain cap, screen termination, elbow termination, tee
termination, mitered termination, and others) can be used with the EZ Seal system. Simply
insert the termination into the female end of the last section of EZ Seal, and then make the
ring-and-tab connection as you normally would.
Termination attaching to EZ Seal, NO sealant required.
Sealant Required
EZ SEAL SAF-T VENT GC
SAF-T VENT CI
EZ SEAL