Manual

Heat & Glo • Escape-36DV • 2012-900 • Rev. AB • 10/08 33
WHT
WHT
BLK
BLK
GRN wire
inside box
Copper
ground attached
to GRN screw with
GRN wire
14/2WG
Cover Plate
outside firebo
Romex
Connector
D. Junction Box Installation
If the box is being wired from the OUTSIDE of
the appliance:
Remove the cover plate located on the outer
shell - right side (see Figure 10.3).
Install the supplied Romex™ connector in the
cover plate.
Feed the necessary length of wire through the
connector.
Make all necessary wire connections and
reattach the cover plate to the outer shell.
If the box is being wired from the INSIDE of the
appliance:
• Remove the screw attaching the junction box/
receptacle to the outer shell, rotate the junction
box inward to disengage it from the outer shell
(see Figure 10.3).
Pull the electrical wires from outside the
appliance through this opening into the valve
compartment.
Figure 10.3 Junction Box Detail
• Feed the necessary length of wire through the connector.
Make all necessary wire connections to the junction box/receptacle
and reassemble the junction box/receptacle to the outer shell.
Note: Do NOT wire
110VAC to wall switch.