Manual

5
Clearance Requirements
The top, back, and sides of the heater are
defined by stand-offs.
The minimum clearance to a perpendicular
wall extending past the face of the heater is
one inch (25mm). The metal ends of the heater
may NOT be recessed into combustible
construction.
Figure 2. Heater Dimensions, Locations,
and Space Requirements
1.1 Locating the Heater
The diagram (See figure 2) shows space and
clearance requirements for locating a heater
within a room.
Minimum Clearances from the Heater to
Combustible Materials
Glass Exhaust Side Opposite Side Top of
Front Floor of Heater of Heater Heater Ceiling
36 inches 0 2-1/2 inch 0 5-1/2 inches 36 inches
(914 mm) (64 mm) (127 mm) (914 mm)
36” (914mm)
36” (914mm)
1” (25mm)
NOTE: The clearance to the ceiling is measured from the top of the unit excluding
standoffs.