3
Framing and Clearances
NOTE:
Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY.
I
llustrations/diagrams are not drawn to scale.
Actual installation may vary due to individual design
preference.
WARNING
Fire Risk
Provide adequate clearance:
Around air openings
To combustibles
For service access
Locate appliance away from traffic areas.
A. Selecting Appliance Location
When selecting a location for your appliance it is important
to consider the required clearances to walls (see Figure 3.1).
Figure 3.1 Appliance Locations
CERONA-36 A B C D E F G
Inches
51 42-1/8 73-1/4 36 65-1/2 1/2 22-1/4
Millimeters
1295 1070 1861 914 1664 13 565
NOTE: For actual appliance dimensions refer to Sec-
tion 16.
In addition to these framing dimensions, also reference the
following sections:
Clearances and Mantel Projections (Section 3.C and 3.D)
Vent Clearances and Framing (Section 6).
ALCOVE
INSTALLATION
A
B
C
D
E
F
G
B
A
CERONA-42 A B C D E F G
Inches
56-5/8 49-1/8 80-1/8 36 72-1/2 1/2 22-1/4
Millimeters
1438 1248 2035 914 1842 13 565