Instructions / Assembly

7
206872-01
SPECIFICATIONS
Range . . . . . . . . . . . . Up to 30 ft. (9.1 m)
[varies with surrounding
temperature]
Sensing Angle . . . . . . Up to 150°
Electrical Load . . . . . . See rating on fixture for
maximum wattage
Sensor Capacity . . . . Up to 360 Watts (3.0
A.) Maximum Tungsten
Incandescent
SYMPTOM
Light stays on
continuously.
Light flashes on
and off.
POSSIBLE CAUSE
1. The sensor is pointed toward
a heat source like an air vent,
dryer vent, or brightly-painted
heat-reflective surface. (Re-aim
sensor.)
2. Light control is in Manual Mode.
(Switch to Auto.)
3. Light control is in DualBrite
®
mode.
4. Sensitivity is set too high. (Re-
duce sensitivity.)
1. Heat being reflected from other
objects may be affecting the
sensor. (Re-aim sensor.)
POSSIBLE CAUSE
1. Light switch is turned off.
2. Bulb is loose or burned out.
3. Fuse is blown or circuit breaker
is turned off.
4. Daylight turn-off is in effect
(recheck after dark).
5. Incorrect circuit wiring, if this is
a new installation.
6. Re-aim the sensor to cover
desired area.
1. Light control may be installed in
a relatively dark location.
2. Light control is in Test. (Set
control switch to an ON-TIME
position.)
1. Light control may be sensing
small animals or automobile
traffic (re-aim sensor).
2. Sensitivity is set too high. (Re-
duce sensitivity.)
SYMPTOM
Light will not
come on.
Light comes on
in daylight.
Light comes on
for no apparent
reason.
TROUBLESHOOTING GUIDE
Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO, and
MANUAL MODE
Time Delay . . . . . . . . 1, 5, 10 minutes
DualBrite
®
Timer . . . . Off, 3, 6 hours, dusk-to
dawn
HeathCo LLC reserves the right to discontinue
products and to change specifications at any
time without incurring any obligation to incorpo-
rate new features in products previously sold.