INSTALL UNIVERSAL MOUNTING
BRACKET
Forbestperformance,mountthextureatleast
8feet(2.4m)abovetheground.
FixtureScrew(Tightened
FingerTight)
JunctionBox
UniversalMounting
Bracket
JunctionBoxScrew
WIRING LIGHT FIXTURE
1. Connectthejunctionboxwiresandthexture
wirestogetherasshowninthefollowingdia-
grams.
CAUTION: DO NOT remove wire connec-
tor from RED wire or connect the RED wire
unless you want to control other lights from
this motion sensor fixture.
DISASSEMBLE LIGHT FIXTURE
1. Removetwodecorativenutsfromlightxture
cover.
2. Removecoverfrombase.
3. Removetwodecorativenutsfromxturescrews
inuniversalmountingbracket.
4. Remove universal mounting bracket from
base.
DecorativeNut
LightFixtureBase
LightFixtureCover
DecorativeNut
Universal
Mounting
Bracket
Note:Ifyouhaveametaljunctionboxusetherecom-
mendedgroundingmethodshowninthefollowing
illustration.Ifyouareuncertainaboutthegrounding
method,consultyourlocalbuildingcode.
2. Twistandsecurewireswithwirenuts.
DualBrite
®
DIMMER CONTROL
Lightcomesonhalfbrightforselectedtimeafterdusk
(Off,3hr.,6hr.,untildawn).SelectingOFFdisablesthis
feature.Themotionsensingfeatureswillcontinueto
workasdescribedinthismanual.Ifmotionissensed,
thelightturnsonfullbrightfortheON-TIME(1,5,or
10minutes)thenreturnstodimmode.
WARNING: Turn power off at circuit
breaker or fuse.
1. Tightenthetwoxturescrewsngertight.
2. Attachuniversalmountingbrackettojunction
boxsecurelywiththetwoscrewsprovided.