Installation Instructions
4
204062-01
TESTING
1. Turn on the circuit breaker and light switch.
Note:Sensorhasa1
1
/
2
minutewarmupperiod
beforeitwilldetectmotion.Whenrstturnedon
wait1
1
/
2
minutes.
2. SettheON-TIMEswitchtotheTESTposition
andtheDualBrite
®
switchtotheOFFposition.
3. Walkthroughthecoverageareanotingwhere
youarewhenthelightsturnon.InTESTmode,
lightwillstayonforonly5secondsthenturn
off.
4. AdjusttheSENSITIVITYtoincreaseordecrease
therangeasneeded.Toomuchsensitivitymay
causefalsetriggeringduetoheatsourcesinthe
coverage area (see Adjustment of Coverage
AreaorTroubleshootingsection).
Itisalsopossibletowiretwomotionsensinglights
sothateitherunitwillturnonbothlightsatthesame
time(dualcontrolledsystem).Itisrecommendedthat
onlypeoplewithelectricalwiringexperienceattempt
thisconguration.Pleasecallourcustomerservice
number (1-800-858-8501) before attempting this
wiring.If the dual controlled wiring is not done
correctly, it can destroy both motion sensing
fixtures and void your warranty.
INSTALL FIXTURE BASE TO
JUNCTION BOX
1. Pushwiresintothejunctionbox.
2. Slide lightxture base onto xture screwsand
tightendecorativenutssnuglyagainstthebase.
3. Install four candelabra base light bulbs (25
Watts maximum each).
4. Refer to TESTING section before installing
cover.
5. Afterswitchesaresetandtestingiscomplete,
usethe2decorativenutstoinstallthecover.
DUAL BRITE
®
ON-TIME
TEST 1
5 10 MIN
OFF 3 6
DUSK
TO DAWN
DualBrite
®
ON-TIME
DUSK
OFF
3
HR 6HR TO DAWN
TEST 1 5 10 MIN
Sensor
Lens
5. SettheamountofON-TIMEyouwantthelight
tostayonaftermotionisdetected(1,5,or10
minutes).
6. Settheamountoftimeyouwantthelightto
stayonintheAccentmode(Off,3hours,6
hours,ordusk-to-dawn).
SENSITIVITY
+
–
+
–
SENSITIVITY
DUAL BRITE
®
ON-TIME
TEST 1
5 10 MIN
OFF 3 6
DUSK
TO DAWN
FixtureScrew
JunctionBox
DecorativeNut
25WattCandelabra
BaseBulb
Maximum Range Coverage Angle*
(Top View)
360°
30Feet(9.1m)
inallDirections
*Withoutlensshieldinstalled.
8ft.(2.4m)