Beforeinstalling,determinethefollowing:
• Typeofchimneyconnectortobeused
-Singlewall,verticalorhorizontal
-Doublewall,verticalorhorizontal
• Consultforclearancestocombustibles
• Poweroutletlocatedclosebyforoptionalblower
Draftisthepressuredifferenceneededtoventappliances
successfully.When a appliance is drafting successfully, all
combustion byproducts are exiting the home through the
chimney.
Considerationsforsuccessfuldraftinclude:
• Preventingnegativepressure
• Locationofapplianceandchimney
T
obesurethatyourapplianceburnsproperly:
• Duringalowburn,thechimneydraft(staticpressure)should
beapproximately-.04inchwatercolumn(W.C.)
• Duringahighburnthechimneydraftshouldbeapproximately
-.10inch(W.C.)
• MeasuretheW.Cat6inches(152mm)abovethetopofthe
applianceafteronehourofoperationateachburnsetting.

NOTICE: Checkbuildingcodespriortoinstallation.
• InstallationMUSTcomplywithlocal,regional,stateand
nationalcodesandregulations.
• Consult insurance carrier, local building inspector, re
ofcialsorauthoritieshavingjurisdictionoverrestrictions,
installationinspectionandpermits.

NOTICE: Hearth & Home Technologies assumes no
responsibilityfortheimproperperformanceoftheappliance
systemcausedby:
• Inadequatedraftduetoenvironmentalconditions
• Downdrafts
• Tightsealingconstructionofthestructure
• Mechanicalexhaustingdevices
Negativepressureresultsfromtheimbalanceofairavail-
ableforthereplacetooperateproperly.Itcanbestron-
gestinlowerlevelsofthehouse.
Causesinclude:
• Exhaustfans(kitchen,bath,etc.)
• Rangehoods
• Combustionairrequirementsforfurnaces,waterheaters
andothercombustionappliances
• Clothesdryers
• Locationofreturn-airventstofurnaceorairconditioning
• ImbalancesoftheHVACairhandlingsystem
• Upperlevelairleakssuchas:
- Recessedlighting
- Attichatch
- Ductleaks
Tominimizetheeffectsofnegativeairpressure:
• Installtheoutsideairkitwiththeintakefacingprevailing
windsduringtheheatingseason
• Ensureadequateoutdoorairforallcombustionappliances
andexhaustequipment
• Ensurefurnaceandairconditioningreturnventsarenot
locatedintheimmediatevicinityofthereplace
• Avoidinstallingthereplaceneardoors,walkwaysorsmall
isolatedspaces
• Recessedlightingshouldbea“sealedcan”design
• Attichatchesweatherstrippedorsealed
• Atticmountedductworkandairhandlerjointsandseams
tapedorsealed
• Basementinstallationsshouldbeavoided
WARNING! Risk of Asphyxiation!
Negativepressurecan
causespillageofcombustionfumesandsoot.Firemustdraft
properlyforsafeoperation.