Stove User Manual

33
Heatilator•ECO-ADV-WS22•7057-128C•August13,2010
8


 Thechimneyconnectorjoinsthestovetothechimney.
• Itmustbea6inch(152mm)minimumdiameter24gauge
mildsteelblack.
• Oranapprovedair-insulateddoublewallventingpipe.
Singlewallconnectororstovepipe
• Mustbeatleast24gaugemildsteel.
• Sectionsmustbeattachedtotheapplianceandtoeach
other with the crimped (male) end pointing toward the
stove.
• Alljoints,includingtheconnectionattheuecollar,should
besecuredwith3sheetmetalscrewsorrivetsasperpipe
manufacturer’sinstructions..
• Followtheminimumclearancestocombustibles
Factory-builtchimneyconnector(vented)
• AListedconnector(vented)mustbeusedwheninstalling
thisunitinamobilehome.
• The Listed connectors must conform to each other to
ensureapropertandseal.
Flue Gas
Direction
Crimped
End
Toward
Stove
Secure pipe sections with a
minimum of 3 screws


A thimble is a manufactured or site-constructed device
installedin combustible walls through which the chimney
connectorpassestothechimney.
• Itisintendedtokeepthewallsfromigniting.
• Site constructed thimbles must meet NFPA 211
Standards.
• Factory-built must be suitable for use with selected
chimneyandmeetUL103TypeHTStandards.
• Follow instructions provided by the manufacturer for
manufacturedthimblesformasonrychimneyandfactory-
builtchimneys.
WARNING! Risk of Fire!
Followchimneyconnectormanufacturer’sinstructionsforproper
installation.
ONLYuseconnector:
• Withintheroom,betweenapplianceandceilingorwall.
ConnectorshallNOTpassthrough:
• Atticorroofspace
• Closetorsimilarconcealedspace
• Floororceiling
Maintainminimumclearancestocombustibles
NOTICE:Wherepassagethroughthewall,orpartition
of combustible construction is desired in Canada, the
installationshallconformtoCAN/CSA-B365.

Chimney Connector:
It is also knownas ue pipe or stove pipe. It must be
6 inches (152mm) minimum diameter stainless steel
connectorpipe.
Chimney:
The chimney can be new or existing, masonry or
prefabricated and must meet the following minimum
requirementsasspeciedbelow.
WARNING! Risk of Fire!
Followventingmanufacturer’sclearancesandinstructions
wheninstallingventingsystem.

Existingchimneysshouldbeinspectedandcleanedbya
qualied professional prior to installation. The chimney
mustnothavecracks,loosemortarorothersignsofdete-
rioration and blockage. Hearth & Home recommends a
NFI or CSIA certied professional or a technician, under
thedirectionofacertiedprofessional,conductaLevelII
inspectionperNFPA211.
NOTICE: Check with your local building authorities
and/orconsulttheNationalFireProtectionAssociation
(NFPA211).

It is recommended that chimneys with larger diameters
than 6 inches (152mm) be relined. An oversized ue
can affect draft and impair performance and will allow
increasedbuild-upofcreosote.