Owner’s Manual Installation and Operation Model(s): NEVO4236I NEVO3630I CAUTION T O N RD O A D SC I D DO NOT DISCARD THIS MANUAL • Important operating and • Read, understand and follow • Leave this manual with party responsible for maintenance instructions these instructions for safe installation and operation. use and operation. included. WARNING WARNING If the information in these instructions is not followed exactly, a fire may result causing property damage, personal injury, or death.
Read this manual before installing or operating this appliance. Please retain this owner’s manual for future reference. A. Congratulations This owner’s manual should be retained for future reference. We suggest that you keep it with your other important documents and product manuals. Congratulations on selecting a Heatilator gas fireplace, an elegant and clean alternative to wood burning fireplaces.
Safety Alert Key: • • • • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE: Used to address practices not related to personal injury. Table of Contents A. Congratulations B. Limited Lifetime Warranty 2 5 1 Listing and Code Approvals A. B.
14 Finishing A. Mantel and Wall Projections B. Facing Material 54 55 15 Appliance Setup A. B. C. D. E. F. G. H. I. Remove the Packaging Remove the Shipping Materials Removing Fixed Glass Assembly Remove Glass Media Package Clean the Appliance Accessories Place the Glass Media Replacing Fixed Glass Assembly Air Shutter Setting 56 56 56 56 56 56 57 58 58 16 Troubleshooting A. Intellifire Ignition System 59 17 Reference Materials A. B. C. D. E.
B. Limited Lifetime Warranty Hearth & Home Technologies Inc. LIMITED LIFETIME WARRANTY Hearth & Home Technologies Inc., on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer.
B.
1 Listing and Code Approvals A. Appliance Certification C. BTU Specifications MODELS: NEVO4236I, NEVO3630I LABORATORY: Underwriters Laboratories, Inc. (UL) TYPE: Vented Gas Fireplace Heaters STANDARD: ANSI Z21.88b-2008 • CSA 2.33b-2008 Novus NEVO3630I NEVO4236I Max/Min Input Rate (NG) 20,000/10,000 25,000/12,500 Orifice Size (NG) 0.083 0.089 / #43 Max/Min Input Rate (LP) 20,000/10,000 23,000/11,500 Orifice Size (LP) 0.053 0.055 / #54 D.
Note: The following requirements reference various Massachusetts and national codes not contained in this document. H.
2 User Guide Operating Instructions • Install a physical barrier such as: - A decorative firescreen. - Adjustable safety gate. • Install a switch lock or a wall/remote control with child protection lockout feature. • Keep remote controls out of reach of children. • Never leave children alone near a hot fireplace, whether operating or cooling down. • Teach children to NEVER touch the fireplace. • Consider not using the fireplace when children will be present.
C. Fan Kit (optional) F. Fixed Glass Assembly If desired, a fan kit may be added. Contact your dealer to order the correct fan kit. See Section 15.D. G. Remote Controls, Wall Controls and Wall Switches D. Clear Space WARNING! DO NOT place combustible objects in front of the fireplace. High temperatures may start a fire. See Figure 2.2. Follow the instructions supplied with the control installed to operate your fireplace: Avoid placing candles and other heat-sensitive objects on mantel or hearth.
H. IPI Battery Tray/Battery Installation • Locate the module selector switch. (See Figure 2.3). The IntelliFire PlusTM system has a battery backup option. Battery longevity and performance will be affected by the service temperatures of this appliance.. • Set the module selector switch to the OFF position. • Wait five (5) minutes to allow possible accumulated gas to clear. NOTICE: Batteries should only be used as a power source in the event of an emergency such as an outage.
K. Lighting Instructions (IPI) • • For normal use, activate/deactivate your fireplace with the wall switch or remote control. The IPI system may be operated with four AA-cell batteries. When using batteries, unplug the power supply. To prolong battery life, remove them when using the power supply. If your fireplace must be deactivated for serviced or an extended period of time, follow the instructions below.
L. After Fireplace is Lit Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • Turn the fireplace off and allow it to completely cool. • Remove fixed glass assembly. See Section 15.D. • Clean fixed glass assembly. See Section 3. • Replace the fixed glass assembly and run continuously on high an additional 12 hours. This cures the materials used to manufacture the fireplace. NOTICE! Open windows for air circulation during fireplace break-in.
3 Maintenance and Service Any safety screen or guard removed for servicing must be replaced prior to operating the fireplace. When properly maintained, your fireplace will give you many years of trouble-free service. We recommend annual service by a qualified service technician. A. Maintenance Tasks-Homeowner Doors, Surrounds, Fronts Frequency: Annually By: Homeowner Tools needed: Protective gloves, stable work surface • • Assess condition of screen and replace as necessary.
B. Maintenance Tasks-Qualified Service Technician Burner Ignition and Operation The following tasks must be performed by a qualified service technician. By: Qualified Service Technician Gasket Seal and Glass Assembly Inspection Frequency: Annually By: Qualified Service Technician Tools needed: Protective gloves, drop cloth and a stable work surface. • Inspect gasket seal and its condition. • Inspect fixed glass assembly for scratches and nicks that can lead to breakage when exposed to heat.
4 Getting Started Installer Guide A. Typical Appliance System NOTICE: Illustrations and photos reflect typical installations and are for design purposes only. Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual Note: Dual venting configurations ARE NOT allowed. Appliance MUST be vented EITHER vertically OR horizontally.
B. Design and Installation Considerations D. Inspect Appliance and Components Heatilator direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. No additional outside air source is required. • Installation MUST comply with local, regional, state and national codes and regulations.
5 Framing and Clearances NOTICE: Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY. Illustrations/diagrams are not drawn to scale. Actual installation may vary due to individual design preference. A. Select Appliance Location When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1). WARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for service access.
B. Construct the Appliance Chase A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should enclosed inside the chase. NOTICE: Treatment of ceiling firestops and wall shield firestops and construction of the chase may vary with the type of building. These instructions are not substitutes for the requirements of local building codes. Therefore, you MUST check local building codes to determine the requirements to these steps.
C. Clearances NOTICE: Install appliance on hard metal or wood surfaces extending full width and depth. DO NOT install directly on carpeting, vinyl, tile or any combustible material other than wood. • WARNING! Risk of Fire! Maintain specified air space clearances to appliance and vent pipe: • • 1/2 in. (13 mm) Insulation and other materials must be secured to prevent accidental contact.
D. Mantel and Wall Projections WARNING! Risk of Fire! Comply with all minimum clearances to combustibles as specified. Framing or finishing material closer than the minimums listed must be constructed entirely of non-combustible materials (i.e., steel studs, concrete board, etc). Mantels Note: All measurements in inches. 30 in.
6 Termination Locations A. Vent Termination Minimum Clearances WARNING Fire Risk. Maintain vent clearance to combustibles as specified. • DO NOT pack air space with insulation or other materials. Failure to keep insulation or other materials away from vent pipe may cause overheating and fire. A B 6 in. (minimum) up to 20 in. 152 mm/508 mm 18 in. minimum 457 mm 20 in. and over 0 in. minimum Gas, Wood or Fuel Oil Termination Cap B Horizontal overhang 24 in. min.
H D O E N V L V C B Fixed Closed V F B Openable Fixed Closed V V V G V B B B V J X M V I A V TERMINATION CAP K X V A GAS METER X AIR SUPPLY INLET Measure vertical clearances from this surface Q RESTRICTION ZONE (TERMINATION NOT ALLOWED) V P W V R V T U Electrical Service U V D* S V Covered Alcove Applications Measure horizontal clearances from this surface.
7 Vent Information and Diagrams A. Approved Pipe Vertical 12 in . DO NOT mix pipe, fittings or joining methods from different manufacturers. The pipe is tested to be run inside an enclosed wall. There is no requirement for inspection openings at each joint within the wall. 8-1/2 in. This appliance is approved for use with Hearth & Home Technologies DVP and/or SLP venting systems. Refer to Section 17.B. for vent component information. 8-1/2 in. WARNING! Risk of Fire or Asphyxiation.
E. Vent Diagrams To replace the first starter elbow with two 45° elbows, refer to Figure 7.4. All other 90° elbows can be replaced with two 45° elbows. General Rules: • • • • • • • SUBTRACT 3 ft. from the total H measurement for each 90° elbow installed horizontally. SUBTRACT 1-1/2 ft. from the total H measurement for each 45° elbow installed horizontally. A maximum of three 90° elbows (or six 45° elbows) may be used in any vent configuration. Some elbows may be installed horizontally. See Figure 7.8.
1. Top Vent - Horizontal Termination - (continued) Two 45° Elbows replacing One 90° Elbow 4 ft min. (1.22 m) 20 ft max. (6.10 m) Figure 7.4 V1 min. Two Elbows V1 max. H1+H2 max. H1+H2+H3 max. ft m ft m ft m ft 1.5 0.46 - - 6 1.83 - - 2 0.61 - - 11 3.35 11 3.35 2.5 0.76 - - 18 5.49 18 5.49 3 0.91 - - 20 6.10 20 6.10 DVP 25 7.62 20 6.10 20 6.10 SLP 23 7.01 20 6.10 20 6.10 Installed Vertically H3 Installed Horizontally H1 H2 H2 Figure 7.
1. Top Vent - Horizontal Termination - (continued) V1 min. Three Elbows V1 + V2 max. H1+H2 max. ft m ft m ft m DVP 2 0.61 24 7.32 19 5.79 SLP 2 0.61 22 6.71 19 5.79 Installed Vertically H2 V2 V1 H1 Figure 7.6 2. Top Vent - Vertical Termination No Elbow 12 ft (3.66 m) min. 60 ft (18.29 m) max. Figure 7.7 Heatilator • Evolution • 4065-114 Rev.
Install Top Vent Flue Baffle - No Elbow Configurations • • • Remove screws holding flue visor to firebox top. See Figure 7.7a. Remove the flue visor. Using the screws removed and the same holes, install the top vent flue baffle and flue visor. - The flue baffle will be turned to install below the level of the firebox top for 12-30 ft vertical runs of vent. See Figure 7.7b. - The flue baffle will be turned to install inside the flue for vertical vent runs of 31-60 ft. See Figure 7.7c. Figure 7.
2. Top Vent - Vertical Termination - (continued) Three Elbows Maximum horizontal run is 100% of vertical, but cannot exceed 17 ft (5.18 m) 12 ft (3.66 m) min. 60 ft (18.29 m) max. Figure 7.8 Heatilator • Evolution • 4065-114 Rev.
2. Top Vent - Vertical Termination - (continued) Two Elbows 12 ft (3.66 m) min. 60 ft (18.29 m) max. Maximum horizontal run is 100% of vertical, but cannot exceed 17 ft (5.18 m) Figure 7.9 30 Heatilator • Evolution • 4065-114 Rev.
3. Rear Vent - Horizontal Termination No Elbow 18 in. (457 mm) max. Figure 7.10 One 45° Elbow NOTICE: To ensure proper operation of appliance, remove the pilot shield when the venting configuration includes a single 45° elbow and horizontal termination. 18 in. (457 mm) max. Remove pilot shield by removing the two screws and lifting the pilot shield out of the appliance as shown. REMOVE PILOT SHIELD Figure 7.11 Heatilator • Evolution • 4065-114 Rev.
3. Rear Vent - Horizontal Termination - (continued) H1 max. Two Elbows ft V1 min. m ft H1+H2 max. m ft m 0 0 1 0.30 3 0.91 2 0.61 1 0.30 3 0.91 4 1.22 2 0.61 6 1.83 6 1.83 3 0.91 9 2.74 8 2.44 4 1.22 12 3.66 8 2.44 5 1.52 15 4.57 8 2.44 6 1.83 18 5.49 V1 H2 H1 Figure 7.12 H1 max. Three Elbows V1 min. ft m ft m ft m 0 0 1 0.30 3 0.91 2 0.61 1 0.30 3 0.91 4 1.22 2 0.61 6 1.83 6 1.83 3 0.91 9 2.74 8 2.44 4 1.22 12 3.
4. Rear Vent - Vertical Termination One Elbow 0 min. 6 ft (1.83 m) max. 12 ft (3.66 m) min. 60 ft (18.29 m) max. Figure 7.14 Two Elbows 12 ft (3.66 m) min. 60 ft (18.29 m) max. 0 min. 6 ft (1.83 m) max. Maximum horizontal run is 100% of vertical, but cannot exceed 18 ft (5.49 m) Figure 7.15 Heatilator • Evolution • 4065-114 Rev.
4. Rear Vent - Vertical Termination - (continued) Three Elbows 0 min. 6 ft (1.83 m) max. 12 ft (3.66 m) min. 60 ft (18.29 m) max. Maximum horizontal run is 100% of vertical, but cannot exceed 18 ft (5.49 m) Figure 7.16 34 Heatilator • Evolution • 4065-114 Rev.
8 Vent Clearances and Framing A. Pipe Clearances to Combustibles B. Wall Penetration Framing WARNING! Risk of Fire! Maintain air space clearance to vent. DO NOT pack insulation or other combustibles: Combustible Wall Penetration • • • Between ceiling firestops Between wall shield firestops Around vent system Failure to keep insulation or other material away from vent pipe may cause over heating and fire. Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm).
C. Install the Ceiling Firestop A ceiling firestop MUST be used between floors and attics. • • • • • DVP pipe only - Frame an opening 10 in. by 10 in. (254 mm by 254 mm) whenever the vent penetrates a ceiling/floor (see Figure 8.3). SLP pipe only - Frame opening 9 in. x 9 in. (229 mm x 229 mm) whenever the vent penetrates a ceiling/floor (see Figure 8.3). Frame the area with the same sized lumber as used in ceiling/floor joist.
D. Install Attic Insulation Shield WARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home Technologies Inc. requires the use of an attic shield. The National Fuel Gas Code ANSI Z223.1 and NFPA 54 requires an attic shield constructed of 26 gauge minimum metal that extends at least 2 in. (51 mm) above insulation. Attic shields must meet specified clearance and be secured in place. Flat Ceiling Installation • Remove one shield from box.
9 Appliance Preparation • A. Top Vent CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during installation. Sheet metal edges are sharp. Fold the center parts of the retaining band up and use to remove the vent cap. NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time. • Remove the cover plate by removing the four screws holding it to the top of the appliance. Remove and discard the cover plate. Figure 9.
B. Rear Vent NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time. • • Discard the vent cap, remove and discard the insulation basket. Fold the tabs toward the center of the vent cap (90º) and remove the insulation gasket. Figure 9.9 Figure 9.6 • • Cut the metal retaining band and fold the sides out. Attach the first vent section (it will snap into place). Slide the insulation gasket onto the vent section, up against the appliance and over the tabs.
C. Secure and Level the Appliance WARNING! Risk of Fire! Prevent contact with: • • • Sagging or loose insulation Insulation backing or plastic Framing and other combustible materials Block openings into the chase to prevent entry of blown-in insulation. Make sure insulation and other materials are secured. DO NOT notch the framing around the appliance standoffs. Failure to maintain air space clearance may cause overheating and fire.
10 Install Vent Pipe A. Assemble Vent Sections (DVP Only) Attach Pipe to the Firebox Assembly Note: The end of the pipe sections with the lanced tabs will face towards the appliance. Attach the first pipe section to the starting collar: • • • • Lanced pipe end to the starting collar Inner pipe over inner collar Push the pipe section until all lanced tabs snap in place Lightly tug on pipe to confirm it has locked.
B. Assemble Vent Sections (SLP Only) To attach the first vent component to the starting collars of the appliance • Attach a DVP-SLP24 adapter to the starting collar of the appliance. Lock the vent components into place by sliding the pipe section onto the collar. Align the seam of the pipe and seam of collar to allow engagement. Rotate the vent component to lock into place. Use this procedure for all vent components. See Figure 10.5.
D. Secure the Vent Sections E. Disassemble Vent Sections • • • • • • • Vertical runs of DVP pipe must be supported every 8 ft. (2.44 m) after the 25 ft. (7.62 m) maximum unsupported rise. Vertical runs of SLP pipe must be supported every 8 ft. (2.44 m). Horizontal sections of vent must be supported every 5 ft. (1.52 m) with a vent support or plumber’s strap. Wall shield firestops may be used to provide horizontal support. Vent support or plumber’s strap (spaced 120° apart) may be used for support.
F. Install Decorative Ceiling Components (SLP only) Level A decorative ceiling thimble can be installed on a flat ceiling through which the vent passes. The decorative ceiling thimble is used to cover the firestop. Cathedral ceiling support box • Seal the gap between the vent pipe and firestop using high temperature silicone to prevent cold air infiltration. • Install the decorative ceiling thimble by sliding it up to the ceiling and attaching it using the provided screws.
G. Install Metal Roof Flashing • • H. Assemble and Install Storm Collar See minimum vent heights for various pitched roofs (Figure 10.14) to determine the length of pipe to extend through the roof. Slide the roof flashing over the pipe sections extending through the roof as shown in Figure 10.15. Horizontal overhang 24 in. min. (610 mm) Termination Cap Storm Collar 20 in. (508 mm) CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during installation.
I. Install Vertical Termination Cap • • Attach the vertical termination cap by sliding the inner collar of the cap into the inner flue of the pipe section while placing the outer collar of the cap over the outer flue of the pipe section. Secure the cap by driving three self-tapping screws (supplied) through the pilot holes in the outer collar of the cap into the outer flue of the pipe (see Figure 10.18). Termination Cap J.
• K. Install Horizontal Termination Cap WARNING! Risk of Fire! The telescoping flue section of the termination cap MUST be used when connecting vent. • 1-1/2 (38 mm) minimum overlap of flue telescoping section is required. Failure to maintain overlap may cause overheating and fire. • • Vent termination must not be recessed in the wall. Siding may be brought to the edge of the cap base. Flash and seal as appropriate for siding material at outside edges of cap.
11 Shrouds A. HHT Shrouds • You may install a shroud with this fireplace. See Section 17.D. for a list of UL Listed shrouds. Follow the instructions included with these optional components B. Field Constructed Shrouds WARNING! Risk of Fire! Shrouds must be constructed as specified. Improper construction may overheat chase top. • Chase top shrouds may be field constructed where permitted by regional building codes. NOTICE: Some regional codes require an agency-Listed shroud.
Mailbox Style Shroud (may be used with DVP-TV, DVP-TVHW, SLP-TVHW) Min. Base Dims. Min. Height in 20 x 20 mm 508 x 508 Min. Height Min. Base Dim in 18 mm 457 Min. Base Dim Figure 11.2 Mailbox Style Shroud Dimensions Roofed Style Shroud (may be used with DVP-TV, DVP-TVHW, SLP-TVHW) Min. Base Dims. in 20 x 20 mm 508 x 508 Min. Height Minimum Height Min. Opening Width Minimum Opening Height Minimum Base Dimension Min. Base Dime nsion in 18 mm 458 Min.
12 Gas Information A. Fuel Conversion C. Gas Connection • • Make sure the appliance is compatible with available gas types. Conversions must be made by a qualified service technician using Hearth & Home Technologies specified and approved parts. • • • B. Gas Pressure • Optimum appliance performance requires proper input pressures. Gas line sizing requirements will be determined in ANSI Z221.3 National Fuel Gas Code in the USA and CAN/ CGA B149 in Canada.
13 Electrical Information C. Optional Accessories Requirements A. Wiring Requirements NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Code CSA C22.1. Wire the appliance junction box to 120 VAC. This is required for use of optional accessories (standing pilot ignition) or proper operation of the appliance (Intellifire ignition).
D. Electrical Service and Repair WARNING! Risk of Shock! Replace damaged wire with type 105° C rated wire. Wire must have high temperature insulation. WARNING! Risk of Shock! Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
E. Junction Box Installation If the box is being wired from the OUTSIDE of the appliance: • • • Romex Connector Remove the cover plate located on the outer shell - right side (see Figure 13.2). Install the supplied Romex™ connector in the cover plate. Make all necessary wire connections and reattach the cover plate to the outer shell.
14 Finishing A. Mantel and Wall Projections WARNING! Risk of Fire! Comply with all minimum clearances to combustibles as specified. Framing or finishing material closer than the minimums listed must be constructed entirely of non-combustible materials (i.e., steel studs, concrete board, etc). Mantels Note: All measurements in inches. 30 in.
B. Facing Material • • • • Metal front faces may be covered with non-combustible materials only. Facing and/or finishing materials must not interfere with air flow through louvers, operation of louvers or doors, or access for service. Facing and/or finishing materials must never overhang into the glass opening. Observe all clearances when applying combustible materials. Finish wall material may be combustible - Top and Sides 0 in.
15 Appliance Setup A. Remove the Packaging • Remove the shrink film, corrugated top cap, bottom cap and column protectors from the appliance. The appliance should look as shown in Figure 15.1. • Pull the four glass assembly latches out of the groove on the glass frame. Refer to Figure 15.2. Remove the glass assembly from the appliance. Latches (both bottom and top) Glass Assembly Figure 15.2 Glass Assembly D. Remove Glass Media Package The glass media package is shipped inside the firebox.
• G. Place the Glass Media WARNING! Risk of Explosion! Follow glass media placement instructions. • DO NOT place glass media in pilot opening. • DO NOT place glass media where they might fall into pilot opening. • DO NOT use any media other than the glass media supplied with this fireplace. • DO NOT place more than one layer of glass media on top of burner. • Open the bag of glass media and place on the burner/ hearth pan area. Spread the glass media over the entire area.
H. Replacing Fixed Glass Assembly I. Air Shutter Setting • Air shutter setting should be adjusted by a qualified installer at the time of installation. • Set the glass panel on the lower two or four glass assembly latches, ensuring the glass panel is centered in the opening. Replace glass latches. See Figure 15.2. • • • The air shutter is set at the factory for minimum vertical vent run. Adjust air shutter for longer vertical runs. See Figure 15.7. Turn the thumbscrew to open and close.
16 Troubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qualified service technician in the diagnosis of a problem and the corrective action to be taken. This troubleshooting guide can only be used by a qualified service technician. Contact your dealer to arrange a service call by a qualified service technician. A. Intellifire Ignition System Symptom 1.
Intellifire Ignition System - (continued) Symptom 4. Pilot sparks, but Pilot will not light. Note: Red LED may flash twice on the Module. Possible Cause A. Gas supply. Verify that incoming gas line shutoff valve is “open”. Verify that inlet pressure reading is within acceptable limits. B. Ignitor gap is incorrect. Verify that spark gap from ignitor to pilot hood is .17 in. or 1/8 in (3 mm). C. Module is not grounded.
17 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 5. C Model A NEVO3630 19 1/8 in. (486 mm) C in. 35 30 8 5/8 mm 889 762 219 NEVO4236 11 5/8 in. (295 mm) B in. 41 36 14 5/8 mm 1041 914 371 A 31 1/2 in. (800 mm) 39 5/8 in. (1006 mm) 39 1/8 in. (994 mm) 3 in. (76 mm) 6 3/4 in. (171 mm) B 1 1/2 in. (38 mm) 2 1/2 in. (64 mm) 6 5/8 in.
B. Vent Components Diagrams Effective Height/Length mm Pipe inches DVP4 DVP6 DVP12 DVP24 DVP36 DVP48 DVP6A DVP12A Effective Height/Length 4 6 12 24 36 48 3-6 3 - 12 4-7/8 in. (124 mm) 102 152 305 610 914 1219 76 - 152 76 - 305 10-1/2 in. (267 mm) 45° 10-7/8 in. (276 mm) DVP45 45° Elbow DVP Pipe (see chart) 10 in. (254 mm) 11-3/8 in. (289 mm) 1 in. (25 mm) 7-3/8 in. (187 mm) 9-1/4 in. (235 mm) 13-1/4 in. (337 mm) Assembled Height: 24 in./610 mm Diameter: 10 in.
B. Vent Components Diagrams (continued) 31 in. (787 mm) 24-5/8 in. (625 mm) 13-1/4 in. (367 mm) 27-1/2 in. (698 mm) 24-5/8 in. (625 mm) 13-1/4 in. (367 mm) RF12M Roof Flashing Multi-pak RF6M Roof Flashing Multi-pak 13-3/4 in. (349 mm) 5 in. (127 mm) 5 in. (127 mm) 11-7/8 in. (302 mm) 13-7/8 in. (352 mm) 13-3/4 in. (349 mm) BEK Trap Cap Brick Extension DVP-BEK2 DVP-HPC Cap Brick Extension 11-5/8 in. (295 mm) 12-1/8 in. (308 mm) 7-1/8 in. (181 mm) 5-3/4 in.
B. Vent Components Diagrams (continued) 7-3/8 in. (187 mm) 1-1/2 in. (38 mm) 9 in. (229 mm) 2-3/4 in. (70 mm) 11-1/2 in. (280 mm) 17-3/4 in. (451 mm) 14 in. (356 mm) 12-1/2 in. (317 mm) 12-1/4 in. (311 mm) 16 in. (406 mm) 12 in. (305 mm) PVK-80 (For use with IPI and DSI appliances only.) DVP-TB1 Basement Vent Cap 3-7/8 in. (98 mm) 10-1/2 in. (267 mm) 7-1/4 in. (184 mm) DVP-TV Vertical Termination Cap 12-1/2 in. (318 mm) 5-1/4 in. (133 mm) DVP-TVHW Vertical Termination Cap (High wind) 1 in.
B. Vent Components Diagrams (continued) Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be used on a wall 4 in. to 7-1/4 in. (102 mm to 184 mm) thick. If wall thickness is less than 4 in. (102 mm) the existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184 mm) a DVP-HSM-B will be required. 8 in. (203 mm) Heat Shield 15-1/8 in. (384 mm) Term Cap Minimum Effective Length Maximum Effective Length 3-1/8 in. 4-5/8 in.
B. Vent Components Diagrams (continued) Fillers DVP-TRAP to DVP-HPC Side Filler Kit 8-1/8 in. (206 mm) 13 in. (330 mm) 15 in. (381 mm) DVP-HRC-SS Effective Length 5-3/4 to 8-3/8 in. 146 to 213 mm 5-1/2 in. 140 mm 87° 8-3/8 in. 213 mm 3° 10-1/2 in. 267 mm 10-7/8 in. 276 mm DVP-HRC-ZC-SS Figure 17.6 DVP Vent Components 66 Heatilator • Evolution • 4065-114 Rev.
B. Vent Components Diagrams (continued) 6-1/2 in. 165 mm 6-1/2 in. 165 mm 8-3/4 in. 222 mm 6 in. 152 mm 6-5/8 in. 168 mm 6-5/8 in. 168 mm SLP-45 - 45° Elbow Effective Height/Length Effective Height/ Length SLP-Pipe 6-1/2 in. 165 mm 9-1/4 in. 235 mm Pipe inches mm SLP4 4 102 SLP6 6 152 SLP12 12 305 SLP24 24 610 SLP36 36 914 SLP48 48 1219 SLP6A 2-6 51 - 152 SLP12A 2 - 12 51 - 305 9-7/8 in. 251 mm SLP-90ST - 90° Elbow DVP-SLP24 Adapter 26 in.
B. Vent Components Diagrams (continued) 9 in. (229 mm) 2-3/4 in. (70 mm) 12-1/2 in. (317 mm) 11-1/2 in. (280 mm) 12-1/4 in. (311 mm) 16 in. (406 mm) SLK-SNKD Snorkel Termination Cap PVK-80 SLP-CCS-BK Cathedral Ceiling Support Box-Black DVP-FBHT Firebrick Termination Cap (This termination cap requires an SL-2DVP adapter when used with SLP Pipe) (For use with IPI and DSI appliances only.) SLP-TVHW Vertical Termination Cap SL-2DVP Adapter 8-1/8 in. (206 mm) 13 in. (330 mm) 15 in.
B. Vent Components Diagrams (continued) Optional Wire Harness 13-5/8 IN. 346 mm EFFECTIVE LENGTH 32 IN. (813 mm) MIN. 35 IN. (889 mm) MAX. DESCRIPTION 12-1/2 IN. 318 mm 20-3/4 IN. 527 mm PART NUMBER 10 ft. PV Wire Harness PVI-WH10 20 ft. PV Wire Harness PVI-WH20 40 ft. PV Wire Harness PVI-WH40 60 ft. PV Wire Harness PVI-WH60 80 ft. PV Wire Harness PVI-WH80 100 ft.
C. Service Parts NEVO3630i Novus Evolution IPI Appliance Beginning Manufacturing Date: Sept 2009 Ending Manufacturing Date:______ 1 2 21 3 20 4 19 5 18 6 8 7 9 17 16 14 15 10 11 12 13 IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer.
NEVO4236i C. Service Parts Beginning Manufacutring Date: Sept 2009 Ending Manufacturing Date: ______ Novus Evolution IPI Appliance 1 2 21 3 20 4 19 5 18 9 8 6 7 17 16 15 14 10 11 12 13 IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer.
NEVO3630i, NEVO 4236i C. Service Parts Beginning Manufacturing Date: Sept 2009 Ending Manufacturing Date: ______ 13.1 #13 Valve Assembly 13.2 13.3 13.17 13.4 13.5 13.15 13.16 13.14 13.6 13.13 13.7 13.8 13.12 13.9 13.11 13.10 IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer.
NEVO3630i, NEVO 4236i C. Service Parts (continued) IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer.
D. Optional Components E D C B C A D B LDS-BV Decorative Shroud A Catalog # A B C E E in. 26 12.5 15.5 22 23 mm 660 318 394 533 584 LDS33/LDS46 Decorative Shroud LDS-BV A B C D Catalog # in. mm in. mm in. mm in. mm LDS33 36 914 36 914 8.5 216 11 279 LDS46 48 1219 72 1829 8.5 216 11 279 20 in. [508 mm] 17 in. [432 mm] 9-3/8 in.
E. Contact Information Please contact your Heatilator dealer with any questions or concerns. For the location of your nearest Heatilator dealer, please visit www.heatilator.com. Heatilator, a brand of Hearth & Home Technologies Inc. 7571 215th Street West, Lakeville, MN 55044 www.heatilator.